首页 | 本学科首页   官方微博 | 高级检索  
     检索      

还原-偶氮光度法测定气体中硝基苯类的改进
引用本文:丁建刚,肖娅,尹玮扬.还原-偶氮光度法测定气体中硝基苯类的改进[J].中国环境监测,2006,22(6):45-47.
作者姓名:丁建刚  肖娅  尹玮扬
作者单位:泰兴市环境监测站,江苏,泰兴,225400
摘    要:因吸收液相对偏多,采气量偏少,过滤液偏少,最后参加显色反应的气体量很少,实验现象是显色溶液全部无色;如果减少吸收液,增加采气量,增加过滤液,使参加显色反应的气体增加很多,这样分析才科学、合理。

关 键 词:吸收液  采气  过滤液  增加  减少
文章编号:1002-6002(2006)06-0045-03
修稿时间:2005年10月16

Improvement with Reduction-azo Photo Method to Monitor Nitrobenzene Series in Atmosphere
DING Jian-gang,et al.Improvement with Reduction-azo Photo Method to Monitor Nitrobenzene Series in Atmosphere[J].Environmental Monitoring in China,2006,22(6):45-47.
Authors:DING Jian-gang  
Abstract:Because of comparatively less absorbing liquid,less sampled gas and less filtered liquid,volume of gas took part in color reaction at last is very little,colored solution for experiment appearance is finally non-color.If we reduce absorbing liquid,add sampled gas and filtered liquid,volume of gas been able to take part in color reaction will be more,thus the analysis result is reasonable.
Keywords:Absorbing liquid  Sampled gas  Filtered liquid  Add  Reduce
本文献已被 CNKI 万方数据 等数据库收录!