紫外光度法臭氧自动监测仪及其标准传递方法
引用本文:鲍雷,刘萍,翟崇治,余家燕.紫外光度法臭氧自动监测仪及其标准传递方法[J].中国环境监测,2015,31(1):128-133.
作者姓名:鲍雷  刘萍  翟崇治  余家燕
作者单位:重庆市环境监测中心, 重庆市城市大气环境综合观测及污染防控重点实验室, 重庆 401147,重庆市环境监测中心, 重庆市城市大气环境综合观测及污染防控重点实验室, 重庆 401147,重庆市环境监测中心, 重庆市城市大气环境综合观测及污染防控重点实验室, 重庆 401147,重庆市环境监测中心, 重庆市城市大气环境综合观测及污染防控重点实验室, 重庆 401147
摘    要:随着我国经济的快速增长和城市化进程的不断加速,以臭氧为主的光化学污染问题已成为大气环境保护领域关注的重点、热点问题。对臭氧进行自动监测是环境管理和科学研究的需要,文中介绍了臭氧自动监测仪和臭氧量值溯源体系,重点探讨了臭氧监测干扰因素及标准传递方法,并通过实验比较验证了带光度计的臭氧校准仪具有较好的输出稳定性。

关 键 词:紫外光度法  臭氧自动监测仪  原理  量值溯源  标准传递
收稿时间:2013/12/25 0:00:00
修稿时间:2014/6/30 0:00:00

Ozone Automatic Monitors Based on Ultraviolet Spectrophotometry and Relevant Standard Transfer Methods
BAO Lei,LIU Ping,ZHAI Chong-zhi and YU Jia-yan.Ozone Automatic Monitors Based on Ultraviolet Spectrophotometry and Relevant Standard Transfer Methods[J].Environmental Monitoring in China,2015,31(1):128-133.
Authors:BAO Lei  LIU Ping  ZHAI Chong-zhi and YU Jia-yan
Institution:Chongqing Urban Key Laboratory of Atmospheric Environment Comprehensive Observation and Pollution Prevention and Control, Chongqing Centre for Enviromental Monitoring, Chongqing 401147, China,Chongqing Urban Key Laboratory of Atmospheric Environment Comprehensive Observation and Pollution Prevention and Control, Chongqing Centre for Enviromental Monitoring, Chongqing 401147, China,Chongqing Urban Key Laboratory of Atmospheric Environment Comprehensive Observation and Pollution Prevention and Control, Chongqing Centre for Enviromental Monitoring, Chongqing 401147, China and Chongqing Urban Key Laboratory of Atmospheric Environment Comprehensive Observation and Pollution Prevention and Control, Chongqing Centre for Enviromental Monitoring, Chongqing 401147, China
Abstract:With the rapid growth of economy and the accelerating of urbanization process, photochemical pollution caused by ozone has become a hot spot in atmospheric environment protection field. Automatic monitoring of ozone is essential for both environment management and scientific research. This study introduced the ozone automated monitor and its quantity traceability system, focusing on interference factors during monitoring and standard transfer methods. It was proved by experiments that the output of ozone calibrator with photometer showed better stability.
Keywords:ultraviolet specterphotometry  automatic ozone analyzer  principles  traceability of value  standard transfer methods