首页 | 本学科首页   官方微博 | 高级检索  
     检索      

地表水中敌百虫测定技术难点探讨
引用本文:陈烨,许秀艳,王超,刀谞,滕恩江,吕怡兵.地表水中敌百虫测定技术难点探讨[J].中国环境监测,2015,31(2):108-113.
作者姓名:陈烨  许秀艳  王超  刀谞  滕恩江  吕怡兵
作者单位:中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012,中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012,中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012,中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012,中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012,中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012
基金项目:流域水生态环境质量监测与评价(2013ZX07502001)
摘    要:地表水中敌百虫的测定,在样品采集保存、前处理及仪器分析各阶段都存在一定的技术难点。实际分析时很容易出现测定结果不理想,甚至是定性定量错误等诸多问题。对敌百虫分析中可能出现的问题及解决途径进行了综述,为地表水中敌百虫的准确测定提供重要的参考依据。

关 键 词:地表水  敌百虫  注意事项  技术难点
收稿时间:2014/2/14 0:00:00
修稿时间:4/3/2014 12:00:00 AM

Discussions about Analysis Difficulties of Determination of Trichlorfon in Surface Water
CHEN Ye,XU Xiu-yan,WANG Chao,DAO Xu,TENG En-jiang and LYU Yi-bing.Discussions about Analysis Difficulties of Determination of Trichlorfon in Surface Water[J].Environmental Monitoring in China,2015,31(2):108-113.
Authors:CHEN Ye  XU Xiu-yan  WANG Chao  DAO Xu  TENG En-jiang and LYU Yi-bing
Institution:State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China,State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China,State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China,State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China,State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China and State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China
Abstract:Analysis difficulties exist in sample collection and preservation, pretreatment and instrumental analysis of trichlorfon determination in surface water. Unsatisfactory results even qualitative and quantitative errors are likely to appear in actual analytical works. In order to provide references for accurate determination, problems and solutions in every step of trichlorfon analysis are reviewed in this paper.
Keywords:surface water  trichlorfon  note items  analysis difficulties
本文献已被 CNKI 等数据库收录!
点击此处可从《中国环境监测》浏览原始摘要信息