气相色谱法测定水和气体样品中的二硫化碳
引用本文:李舒.气相色谱法测定水和气体样品中的二硫化碳[J].中国环境监测,1998(3).
作者姓名:李舒
作者单位:河南省环境监测中心站
摘    要:本文研究了用气相色谱电子捕获检测器测定水和气体样品中二硫化碳的方法。本方法采取顶空进样法测水质样品,直接进样测气体样品。色谱柱为GDX—101填充柱。方法简单,灵敏度高,水质样品最低检出浓度可达00005mg/L,气体样品最低检出浓度达0005mg/m3。方法的精密度为57%,回收率为903%。

关 键 词:二硫化碳,水和气体样品,气相色谱

Determinating the Sulfur Dioxide in Water and Air Samples by Gas Chromatography.
Li Shu.Determinating the Sulfur Dioxide in Water and Air Samples by Gas Chromatography.[J].Environmental Monitoring in China,1998(3).
Authors:Li Shu
Abstract:This article studied the method of determinating the sulfur dioxide in water and air samples by gas chromatographic detector.The method determinates the water samples with head space sampling,and determinates the air samples with derectly sampling.The chromatographic column used in this method is the type of GDX 101.So,the method has high senstiveness;the lowest limit of detection in water and air samples is 0 0005 mg/L and 0 005mg/m 3,respectively.The degree of precision and recovery rate of this method is 5 7% and 90 3%,respectively.
Keywords:Sulfur dioxide  Water and air samples  Gas chromatography  