首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于便携式氢火焰离子化检测器法测定固定污染源废气中非甲烷总烃的研究
引用本文:谢馨,韩颖,秦承华.基于便携式氢火焰离子化检测器法测定固定污染源废气中非甲烷总烃的研究[J].中国环境监测,2020,36(1):120-124.
作者姓名:谢馨  韩颖  秦承华
作者单位:江苏省南京环境监测中心,江苏 南京210013,江苏省南京环境监测中心,江苏 南京210013,中国环境监测总站,国家环境保护环境监测质量控制重点实验室,北京100012
基金项目:国家重点研发计划“大气污染成因与控制技术研究”专项(2016YFC0208204)
摘    要:通过实验室和固定污染源废气现场比对测试,对便携式氢火焰离子化检测器法(催化氧化法和气相色谱法)测定非甲烷总烃的检出限、转化效率、精密度和准确度等性能指标开展研究。实验室测试结果表明,便携式氢火焰离子化检测器法测定非甲烷总烃的检出下限(0.3 mg/m^3)、转化效率(98.2%)、精密度(3.49%)、准确度(-2.38%)基本满足方法技术指标的要求,但是对于催化氧化法还需重点关注其转化效率。固定污染源废气现场比对测试结果表明,便携式氢火焰离子化检测器法与实验室方法测试结果的相对准确度(33.2%)、相对误差(-9.27%~23.7%)基本能满足测试方法的测试要求,趋势性也保持一致,适用于现场测试。

关 键 词:固定污染源  便携式氢火焰离子化检测器法  气相色谱  催化氧化  非甲烷总烃
收稿时间:2019/1/22 0:00:00
修稿时间:2019/7/11 0:00:00

Determination of Non-methane Total Hydrocarbon in Exhaust Gas from Stationary Source Based on Portable Hydrogen Flame Ionization Detector
XIE Xin,HAN Yin and QIN Chenghua.Determination of Non-methane Total Hydrocarbon in Exhaust Gas from Stationary Source Based on Portable Hydrogen Flame Ionization Detector[J].Environmental Monitoring in China,2020,36(1):120-124.
Authors:XIE Xin  HAN Yin and QIN Chenghua
Institution:Nanjing Environmental Monitoring Center, Nanjing 210013, China,Nanjing Environmental Monitoring Center, Nanjing 210013, China and State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China
Abstract:Through field comparison and testing of exhaust gas from laboratory and stationary sources, the lower detection limit, conversion efficiency, precision and accuracy of portable hydrogen flame ionization detector method(catalytic oxidation method and gas chromatography) were studied. The results of laboratory tests showed that the basic data were obtained by testing the lower detection limit of the method(0.3 mg/m3), conversion efficiency(98.2%), precision(3.49%), and accuracy(-2.38%), which basically met the requirements of the method technical indicators., However, the conversion efficiency of catalytic oxidation method should be focused on. The field comparison test results of the stationary source exhaust gas showed that the relative accuracy(33.2%) and relative error(-9.27% to 23.7%) of the test results of the portable hydrogen flame ionization detector method and the laboratory method can basically meet the test requirements of the test method. Trends are also consistent and suitable for field testing.
Keywords:stationary source  portable hydrogen flame ionization detector  gas chromatography  catalytic oxidation  non-methane total hydrocarbon
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国环境监测》浏览原始摘要信息
点击此处可从《中国环境监测》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏