首页 | 本学科首页   官方微博 | 高级检索  
     检索      

自动进样系统结合分光光度法快速测定水质中总磷
引用本文:魏凤,朱颖,陈阳,龙雯琪,刘荔彬,毕军平,刘沛,张霖琳.自动进样系统结合分光光度法快速测定水质中总磷[J].中国环境监测,2021,37(6):193-199.
作者姓名:魏凤  朱颖  陈阳  龙雯琪  刘荔彬  毕军平  刘沛  张霖琳
作者单位:湖南省生态环境监测中心, 国家环境保护重金属污染监测重点实验室, 湖南 长沙 410019;力合科技(湖南)股份有限公司, 湖南 长沙 410082;中国环境监测总站, 国家环境保护环境监测质量控制重点实验室, 北京 100012
基金项目:国家重点研发计划(2017YFF0108200);湖南省环境保护科技项目(湘财建指〔2010〕277号)
摘    要:基于自动进样系统结合分光光度法,通过对波长、消解条件及显色条件的优化,建立了水中总磷的快速检测分析方法。在优化条件下,总磷的检出限为0.005 mg/L,测定下限为0.020 mg/L。对地表水、生活污水和工业废水3种不同基质的样品进行了加标测定,其回收率为95.0%~102%,相对标准偏差为0.5%~2.7%;与国标方法钼酸铵分光光度法测定水体中总磷进行比对研究,对国家有证标准样品、地表水、生活污水和工业废水测试的结果显示,方法相对偏差为0.4%~3.5%。该方法操作简单、快速、准确,可为应对突发环境事件中总磷的测定提供技术参考。

关 键 词:水质  总磷  应急监测  自动进样系统
收稿时间:2020/12/17 0:00:00
修稿时间:2021/6/10 0:00:00

A Method Using Automatic Sampling System Combined with Spectrophotometry for Rapid Determination of Total Phosphorus in Water
WEI Feng,ZHU Ying,CHEN Yang,LONG Wenqi,LIU Libin,BI Junping,LIU Pei,ZHANG Linlin.A Method Using Automatic Sampling System Combined with Spectrophotometry for Rapid Determination of Total Phosphorus in Water[J].Environmental Monitoring in China,2021,37(6):193-199.
Authors:WEI Feng  ZHU Ying  CHEN Yang  LONG Wenqi  LIU Libin  BI Junping  LIU Pei  ZHANG Linlin
Institution:State Environmental Protection Key Laboratory of Monitoring for Heavy Metal Pollutants, Hunan Ecological and Environmental Monitoring Center, Changsha 410019, China;Lihe Technology (Hunan) Co, Ltd, Changsha 410082, China; State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China
Abstract:Based on automatic sampling system and spectrophotometry,a rapid determination and analysis method for total phosphorus(TP) in water was established by selecting the optimal wavelength,digestion conditions and chromogenic conditions.Under the optimal conditions,the detection limit of TP was 0.005 mg/L and the determination limit was 0.020 mg/L.The recovery of surface water,groundwater,domestic sewage and industrial wastewater was between 95.0%-102%,and the relative standard deviation was between 0.5%-2.7%.This determination method and ammonium molybdate spectrophotometry were simultaneously and respectively used to verify the result by national certified standard samples,surface water,domestic sewage and industrial wastewater.The relative deviation was between 0.4%-3.5%,and the detection results were basically consistent.The results showed that the method could provide reliable technical support for the simple,rapid and accurate determination of TP in environmental emergencies.
Keywords:water  total phosphorus  emergency monitoring  auto-sampling system
点击此处可从《中国环境监测》浏览原始摘要信息
点击此处可从《中国环境监测》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏