首页 | 本学科首页   官方微博 | 高级检索  
     检索      

吹扫捕集-气相色谱/质谱法测定饮用水源水中乙醛
引用本文:叶朝霞,胡文凌,庞明,李莉,冷眩.吹扫捕集-气相色谱/质谱法测定饮用水源水中乙醛[J].中国环境监测,2009,25(6).
作者姓名:叶朝霞  胡文凌  庞明  李莉  冷眩
作者单位:嘉兴市环境保护监测站,浙江,嘉兴,314000
摘    要:建立了吹扫捕集-气相色谱/质谱法(GC-MS)测定饮用水源地水中乙醛的方法。方法的检出限为0.5μg/L,相对标准偏差为3.9%~4.6%,加标回收率为92.5%~97.8%。该方法操作简单,灵敏度高,适用于水源水中乙醛的测定。

关 键 词:吹扫捕集  气相色谱/质谱法  饮用水  乙醛  

Determination of Acetaldehyde in Drinking Source Water by Purge and Trap-gas Chromatography-mass Spectrometry
YE Zhao-xi,et al.Determination of Acetaldehyde in Drinking Source Water by Purge and Trap-gas Chromatography-mass Spectrometry[J].Environmental Monitoring in China,2009,25(6).
Authors:YE Zhao-xi  
Institution:Jiaxing Environmental Protect Monitoring Station;Jiaxing 314000;China
Abstract:The method of determination of acetaldehyde in water by purge and trap-gas chromatography-maas spectrometry was established in this paper. The method detection limits for acetaldehyde was 0.5μg/L. The relative standard derivation was in a range of 3.9%~ 4.6%. The recovery of the method was 92.5%~97.8% . The method was easy to operation and sensitive for the determination of acetaldehyde in water.
Keywords:Purge and trap  Gas chromatography-mass spectrometry  Drinking water  Acetaldehyde  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国环境监测》浏览原始摘要信息
点击此处可从《中国环境监测》下载免费的PDF全文