首页 | 本学科首页   官方微博 | 高级检索  
     检索      

离子色谱法测定丙烯酸丁酯生产废水中丙烯酸和对甲基苯磺酸
引用本文:范志庆,宋玉栋,周岳溪.离子色谱法测定丙烯酸丁酯生产废水中丙烯酸和对甲基苯磺酸[J].中国环境监测,2010,26(3):26-28.
作者姓名:范志庆  宋玉栋  周岳溪
作者单位:1. 中国矿业大学(北京)化学与环境工程学院,北京,100083;中国环境科学研究院水污染控制技术研究中心,北京,100012
2. 中国环境科学研究院水污染控制技术研究中心,北京,100012
基金项目:国家水体污染控制与治理科技重大专项(2008ZX07207-004)
摘    要:建立了用离子色谱法测定丙烯酸丁酯生产废水中丙烯酸和对甲基苯磺酸的新方法。采用IonPac AS11-HC阴离子色谱柱,淋洗液为30mmol/L的NaOH淋洗液,流速1ml/min,抑制电流75mA。丙烯酸根的检测下限为0.44mg/L(峰面积)、0.46mg/L(峰高),保留时间、峰高、峰面积的变异系数分别为0.03%、0.50%、0.50%,峰高、峰面积的线性回归系数R分别为0.9929、0.9954。对甲基苯磺酸根的检测下限为0.49mg/L(峰面积)、0.48mg/L(峰高),保留时间、峰高、峰面积的变异系数分别为0.02%、0.48%、0.47%,峰高、峰面积的线性回归系数R分别为0.9990、0.9998。常规无机阴离子对丙烯酸、对甲基苯磺酸的测定没有干扰。对实际废水样品进行分析,丙烯酸、对甲基苯磺酸的回收率分别为101.6%~104.4%、95.4%~96.8%。方法简便、灵敏、可靠。

关 键 词:TOC  高锰酸盐指数  相关性  应用  丙烯酸  对甲基苯磺酸  离子色谱
收稿时间:2009/8/23 0:00:00
修稿时间:2009/11/25 0:00:00

Determination of Acrylic Acid and P-toluenesulfonic Acid in Butyl Acrylate-Production Wastewater by Ion Chromatography
FAN Zhi-qing.Determination of Acrylic Acid and P-toluenesulfonic Acid in Butyl Acrylate-Production Wastewater by Ion Chromatography[J].Environmental Monitoring in China,2010,26(3):26-28.
Authors:FAN Zhi-qing
Institution:School of Chemical and Environmental Engineering, China University of Mining and Technology (Beijing), Beijng 100083, China; Research Center of Water Pollution Control Technology, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
Abstract:A new method is established for the analysis of acrylic acid and p-toluenesulfonic acid in butyl acrylate-production wastewater by ion chromatography. The IonPac AS11-HC column was used as anion separation column with 30mmol ·L-1 NaOH as eluent. The eluent flow rate was 1ml ·min-1 and the suppression current was 75mA. For acrylic acid, the detection limit of the method were 0.44mg ·L-1 for area, 0.46mg ·L-1 for height. The relative standard deviations were 0.03% for retention time, 0.50% for height and 0.50% for area, respectively. The correlation coefficients of the calibration curve were 0.9954 for area and 0.9929 for height. For p-toluenesulfonic acid, the detection limit were 0.49mg ·L-1 for area, 0.48mg ·L-1 for height. The relative standard deviations were 0.02% for retention time, 0.48% for height and 0.47% for area, respectively. The correlation coefficient of the calibration curve were 0.9990 for area and 0.9998 for height. Common inorganic anions did not interfere. The recovery percentages were 101.6%~104.4% for acrylic acid, 95.4%~96.8% for p-toluenesulfonic acid, respectively. The method is simple, sensitive and reliable.
Keywords:Acrylic acid  P-toluenesulfonic acid  Ion chromatography