低温储罐三通切换阀管件失效分析
引用本文:李云,张红星,朱潮明.低温储罐三通切换阀管件失效分析[J].中国特种设备安全,2014(8):33-36.
作者姓名:李云  张红星  朱潮明
作者单位:嘉兴市特种设备检测院,嘉兴314050
摘    要:在低温储罐定期检验中,发现储罐底部一个三通切换阀管件上存在多处裂纹及泄漏现象。通过对失效件进行宏观检验、化学成分、电镜扫描、金相组织、腐蚀产物能谱、非金属夹杂物含量、显微硬度等进行测试,结果表明:管件材质低于设计要求,管件承受载荷及应力作用,存在CI-等奥氏体不锈钢腐蚀敏感介质,造成该处奥氏体不锈钢管件应力腐蚀失效。

关 键 词:低温储罐  裂纹  失效分析  SEM  能谱分析

Failure Analysis on Three Switching Valve Fittings of Cryogenic Tank
Authors:Li Yun Zhang Hongxing Zhu Chaoming
Institution:Li Yun Zhang Hongxing Zhu Chaoming (Jia xing Special Equipment Inspection Institute Jiaxing 314050)
Abstract:Cracks and leaks were found on the switching valve during a periodic inspection on a cryogenic tank. The test results showed the material of the tube didn't match the requirement of the standard through macroscopic examination, chemical composition, SEM, metallurgical analysis, EDS Analysis and micro-hardness test. It was concluded that the stress corrosion lead to the failure on the co-effect of load and stress, chemical composition and the corrosion of CI-.
Keywords:Cryogenic tank  Failure analysis  SEM EDS analysis