首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Permeability of Medical Gloves to Mono- and Dimethacrylate Monomers in Dental Restorative Materials
Authors:Emma-Christin Lönnroth  I Eystein Ruyter
Institution:1. Department of Human Work Science, Lule? University of Technology, Lule? Sweden Scandinavian Institute of Dental Materials (NIOM), Haslum, Norwayemma@arb.luth.se;3. Scandinavian Institute of Dental Materials (NIOM), Haslum Norway
Abstract:Dental personnel manually handle methacrylate-based restorative materials, which can cause skin irritation and allergies. The protection given by different types of medical gloves is not well known. Breakthrough time (BTT, min) was used as a measure of protection according to a European standard, using 2 test mixtures consisting of respectively 3 and 5 monomers. Fourteen gloves representing natural rubber latex, synthetic rubber, and synthetic polymeric material were tested. The BTT ranged from some minutes to more than 2 hrs for the 4 monomers with a molecular mass less than 300. The longest protection was recorded for Nitra Touch (nitrile rubber), Tactylon (synthetic rubber), and Metin (PVC).
Keywords:protection  methacrylates  composites  resins  adhesives
设为首页 | 免责声明 | 关于勤云 | 加入收藏