首页 | 本学科首页   官方微博 | 高级检索  
     检索      


PLS-based EWMA fault detection strategy for process monitoring
Institution:1. Chemical Engineering Program, Texas A&M University at Qatar, Doha, Qatar;2. Electrical and Computer Engineering Program, Texas A&M University at Qatar, Doha, Qatar;1. Chemical Engineering Program, Texas A&M University at Qatar, Doha, Qatar;2. Electrical and Computer Engineering Program, Texas A&M University at Qatar, Doha, Qatar;1. College of Information Science and Engineering, Northeastern University, Shenyang 110819, Liaoning, PR China;2. State Key Laboratory of Synthetical Automation of Process Industry, Northeastern University, Shenyang 110819, Liaoning, PR China;1. Institute for Automatic Control and Complex Systems, University of Duisburg-Essen, Bismarckstrasse 81 BB, 47057 Duisburg, Germany;2. School of Physics and Electronics, Central South University, 410083 Changsha, China;1. Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77840, United States;2. Chemical Engineering Program, Texas A&M University at Qatar, Doha, Qatar;3. Electrical and Computer Engineering Program, Texas A&M University at Qatar, Doha, Qatar
Abstract:Fault detection (FD) and diagnosis in industrial processes is essential to ensure process safety and maintain product quality. Partial least squares (PLS) has been used successfully in process monitoring because it can effectively deal with highly correlated process variables. However, the conventional PLS-based detection metrics, such as the Hotelling's T2 and the Q statistics are ill suited to detect small faults because they only use information from the most recent observations. Other univariate statistical monitoring methods, such as the exponentially weighted moving average (EWMA) control scheme, has shown better abilities to detect small faults. However, EWMA can only be used to monitor single variables. Therefore, the main objective of this paper is to combine the advantages of the univariate EWMA and PLS methods to enhance their performances and widen their applicability in practice. The performance of the proposed PLS-based EWMA FD method was compared with that of the conventional PLS FD method through two simulated examples, one using synthetic data and the other using simulated distillation column data. The simulation results clearly show the effectiveness of the proposed method over the conventional PLS, especially in the presence of faults with small magnitudes.
Keywords:Partial least squares  Statistical fault detection  Small faults  Data-based fault detection  EWMA control scheme  Distillation columns
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号