摘    要:研究了H_2O_2和其它氧化剂(以过氧化苯甲酰为例)对DPD法测定水中臭氧浓度的干扰作用,结果表明,随着KI浓度或显色时间的增加,H_2O_2和其它氧化剂的干扰作用增加,当KI浓度为0.5g/L时,可以基本消除这些干扰作用,且当臭氧浓度低于0.6mg/L时,不影响臭氧对DPD的显色作用。

关 键 词:DPD法,臭氧测定,干扰分析

Investigation on Eliminating Interference in the Determination of Ozone Concentration in Aqueous Solutions by DPD Method
Wang Yeyao,Lu Xing and Wang Zbansheng.Investigation on Eliminating Interference in the Determination of Ozone Concentration in Aqueous Solutions by DPD Method[J].Environmental Protection of Chemical Industry,1996(3).
Authors:Wang Yeyao  Lu Xing and Wang Zbansheng
Abstract:The interference from hydrogen peroxide and other oxidants (benzoyl peroxide) in the determination of ozone concentration in aqueous solutions by DPD method have been investigated.The experimental results showed that the interference increased with the increment of potassium iodide concentration or color developing time;however,when potassium iodide concentration was as low as 0.5g/L,the interference could be essentially eliminated;and when ozone concentration was below 0.6mg/L,the color developing reaction of DPD with ozone was not interfered.
Keywords:s:DPD method  ozone determination  interference analysis  