摘    要:在系统阐述污水生物除磷机理的基础上,深入分析了微生物群体平衡、城市污水水质、环境因子以及工艺运行参数和运行方式等方面对生物除磷效果的影响.分析结果表明:生物除磷系统的溶解氧浓度不宜太高,一般好氧区DO<2 mg/L,厌氧区DO<0.2 mg/L;厌氧段存在硝酸盐对生物释磷有负面影响,缺氧段存在一定浓度的硝酸盐有利于生物聚磷;碳源必须充分、易降解;TKN/COD<0.1的城市污水有利于生物除磷;pH偏碱性可提高生物除磷效率;低温对生物除磷效果影响不明显.

关 键 词:城市污水  生物除磷  影响因素  污水生物除磷  影响因素分析  sewage  treatment  biological  phosphorus  removal  低温  除磷效率  偏碱性  降解  碳源  聚磷  溶解氧浓度  缺氧段  释磷  硝酸盐  存在  厌氧区  好氧区  生物除磷系统  结果  除磷效果
文章编号:1673-9108(2007)04-0006-06
修稿时间:2006-06-202006-09-30

Influencing factors of biological phosphorus removal in sewage treatment
Yin Jun,Wang Jianhui,Wang Xuefeng,Xie Yancui,Huo Yufeng and Tan Xuejun.Influencing factors of biological phosphorus removal in sewage treatment[J].Techniques and Equipment for Environmental Pollution Control,2007,1(4):6-11.
Authors:Yin Jun  Wang Jianhui  Wang Xuefeng  Xie Yancui  Huo Yufeng and Tan Xuejun
Institution:School of Municipal and Environmental Engineering,Jilin Architectural and Civil Engineering Institute, Changchun 130021,School of Municipal and Environmental Engineering,Jilin Architectural and Civil Engineering Institute, Changchun 130021,School of Municipal and Environmental Engineering,Jilin Architectural and Civil Engineering Institute, Changchun 130021,School of Municipal and Environmental Engineering,Jilin Architectural and Civil Engineering Institute, Changchun 130021,School of Municipal and Environmental Engineering,Jilin Architectural and Civil Engineering Institute, Changchun 130021 and School of Municipal and Environmental Engineering,Jilin Architectural and Civil Engineering Institute, Changchun 130021
Abstract:Based on the introduction of mechanism of biological phosphorus removal,the influences of microorganisms' population balance,wastewater quality,environmental factors,operating parameters and manner on phosphorus removal effect were adequately analyzed in this paper.Among all influencing factors,too high dissolved oxygen(DO) concentration must be avoided,which in aerobic zone should be less than 2 mg/L and which in anaerobic zone less 0.2 mg/L.Nitrate in anaerobic zone exhibited negative effect on phosphorus release,but certain concentration of nitrate in anoxic zone was beneficial to phosphorus accumulation.Carbon source must be adequate and easily degraded.Municipal wastewater with TKN/COD<0.1 was helpful to biological phosphorus removal.Alkalescent environment could increase the effect of phosphorus removal.The influence of low temperature on phosphorus removal was not evident.
Keywords:municipal wastewater  biological phosphorus removal  influencing factors