首页 | 本学科首页   官方微博 | 高级检索  
     检索      


On the correlation of air and pollutant exchange for street canyons in combined wind-buoyancy-driven flow
Authors:WC Cheng  Chun-Ho Liu  Dennis YC Leung
Institution:1. The University of Tokyo, Tokyo, Japan;2. Institute of Industrial Science, The University of Tokyo, Tokyo, Japan;1. State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, China;2. Key Laboratory of Thermo-Fluid Science and Engineering of MOE, School of Energy and Power Engineering, Xi''an Jiaotong University, Xi''an, China;1. Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland;2. ETH, Swiss Federal Institute of Technology Zürich, Zürich, Switzerland;3. KIT, Karlsruhe Institute of Technology, Karlsruhe, Germany;4. TU/e, Eindhoven University of Technology, Eindhoven, The Netherlands;1. School of Power and Mechanical Engineering, Wuhan University, Wuhan, Hubei Province, China;2. Shenzhen Research Institute, Wuhan University, Shenzhen, Guangdong Province, China;3. School of the Built Environment, University of Reading, Reading, United Kingdom;4. School of Civil Engineering, University of South China, Hengyang, Hunan Province, China;1. Department of Atmospheric Sciences, School of Environmental Science and Engineering of Sun Yat-Sen University, Guangzhou, PR China;2. Laboratory of Ventilation and Air Quality, University of Gävle, SE-80176 Gävle, Sweden;3. Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, University of Salento, S.P. 6 Lecce-Monteroni, 73100 Lecce, Italy;4. Department of Physics and Astronomy, ALMA MATER STUDIORUM - University of Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy
Abstract:The ventilation and pollutant transport in a two-dimensional (2D) street canyon of building-height-to-street-width (aspect) ratio h/b = 1 under different unstable stratifications were examined. To characterize the combined wind-buoyancy-driven flow and pollutant transport at different Richardson number Ri, a computational fluid dynamics (CFD) model based on the Reynolds-averaged Navier–Stokes (RANS) equations with the Renormalization Group (RNG) k ? ε turbulence model was adopted. Unlike the isothermal condition, a secondary recirculation is initiated at the ground-level windward corner of the street canyon once the unstable stratification is switched on (Ri < 0). It traps the ground-level pollutant leading to elevated pollutant concentration there. As Ri further decreases, the enlarging secondary recirculation enables direct pollutant removal from its core to the shear layer that offsets the ground-level pollutant accumulation. The ventilation and pollutant removal performance under different unstable stratifications are compared by the air (ACH) and pollutant (PCH) exchange rates, and pollutant retention time (τ). Both the mean and turbulent components of ACH are found to increase with decreasing Ri, suggesting that unstable stratification promotes ventilation in street canyons. Moreover, the CFD results agree well with our theoretical model that ACH2 varies linearly with Ri. Turbulent transport originally dominates the pollutant removal under isothermal condition. However, progressive domination of pollutant removal by mean wind can be observed with decreasing stability (decreasing Ri from 0 to ?10.6). The critical value is estimated to be Ri = ?8, below which mean wind is the major pollutant removal carrier. Reduction in τ is also observed with decreasing Ri. Hence, in unstable stratification, pollutant resides shorter time in the street canyon compared with its isothermal counterpart, and the ventilation and pollutant removal are more favorable.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号