首页 | 本学科首页   官方微博 | 高级检索  
     检索      

厌氧—好氧反应系统处理含酚废水的研究
引用本文:强志民,赵俊锳,王建民.厌氧—好氧反应系统处理含酚废水的研究[J].环境污染与防治,1997,19(2):1-4,38.
作者姓名:强志民  赵俊锳  王建民
作者单位:同济大学环境工程学院!上海200092,同济大学环境工程学院!上海200092,Dept.ofCivilEngr,Unvi.ofDelaware,Newark,DE19716
摘    要:利用好氧污泥转厌氧驯化方法在厌氧复合床内接种培养,处理浓度为1000mg/L左右的含酚废水。研究结果表明,在水力停留时间1d,酚容积负荷1.06kg/(m3·d)的条件下,厌氧复合床内培养出颗粒污泥,处理效果明显提高,本酚去除率达98.7%,COD去除率达98.3%。此时后接一个好氧接触氧化柱,最终出水中检不出酚。

关 键 词:厌氧  好氧  厌氧复合床  含酚废水  废水处理

Treatment of Phenolic Wastewater with Anaerobic-aerobic Combination System
Qiang Zhimin.Treatment of Phenolic Wastewater with Anaerobic-aerobic Combination System[J].Environmental Pollution & Control,1997,19(2):1-4,38.
Authors:Qiang Zhimin
Abstract:A lab-scale experiment for treating phenolic wastewater of about 1000 mg/L was conducted oy a combined anaerobic bed. The results indicated that aerobic sludge was seeded and cultivated in an anaerobic bed for a period, the granular sludge formed gradually and treatment effeciency was enhanced. Wheh the reactor reached volumetric loading rate of 1.06 kg phenol/m3. d and hydraulic retention time of 1.0 d, the phenol and COD removal could reach 98. 7 % and 98. 3 % respectively. The effluent from anaerobic bed was treated with aerobic contact reactor, and phenol in the final effluent could not be detected.
Keywords:Anaerobic-aerobic combination system Combined anaerobic bed reactor Phenolic wastewater  