接种稀释水的空白对BOD_5测定的影响
引用本文:谢美云.接种稀释水的空白对BOD_5测定的影响[J].环境污染与防治,2000(5).
作者姓名:谢美云
作者单位:福建省三明环境监测站!福建三明365000
摘    要:从接种液种类、空白 BOD5大小、接种液最佳添加范围等方面对 BOD5测定进行探讨 ,提出以接纳工业废水的河水作为最佳接种液 ,雨季时以土壤浸取液更适合。探讨了接种液空白值对 BOD5标液和工业废水的影响。结果表明 ,河水空白应控制在 0 .1~0 .8mg/ L,土壤浸取液空白控制在 0 .0 1~ 0 .1 0 mg/ L为宜。

关 键 词:接种稀释水  BOD_5  测定

Influences of inoculated diluting water on BOD_5 determination
Xie Meiyun,Sanming Environmental Monitoring Station,Fujian Sanming.Influences of inoculated diluting water on BOD_5 determination[J].Environmental Pollution & Control,2000(5).
Authors:Xie Meiyun  Sanming Environmental Monitoring Station  Fujian Sanming
Institution:Xie Meiyun,Sanming Environmental Monitoring Station,Fujian Sanming 365000
Abstract:s:Effects of the inoculated solution type,the BOD 5 blank and the inoculated solution volume on BOD 5 determination was studied.The results showed that the river water,which took in industrial wastewater,was suitable inoculated solution in general,while the soil extraction was much better in raining time.The influences of inoculated solution blank on the BOD 5 standard solution and industrial wastewater were studied also.The data obtained indicated that the blank of river water and soil extraction should be controlled within 0 1~0 8 mg/L and 0 01~0 10 mg/L respectively.
Keywords:Inoculated diluting water    BOD  5    Determination