首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Performance evaluation of a bipolar electrolysis/electrocoagulation (EL/EC) reactor to enhance the sludge dewaterability
Authors:Hamed Gharibi  Mohammad Hossein Sowlat  Amir Hossein Mahvi  Morteza Keshavarz  Mohammad Hossein Safari  Saeedeh Lotfi  Mahnaz Bahram Abadi  Azim Alijanzadeh
Institution:1. Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Enghelab Street, Tehran, Iran;2. Students’ Scientific Research Center (SSRC), Tehran University of Medical Sciences, Tehran, Iran;3. Young Researchers Club, Medical Branch, Islamic Azad University, Tehran, Iran;4. National Institute of Health Research, Tehran University of Medical Sciences, Tehran, Iran;7. Center for Solid Waste Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran;8. Department of Environment and Energy, Science and Research Branch, Islamic Azad University, Tehran, Iran;9. Department of Environmental Health Engineering, Faculty of Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract:The present study aimed to evaluate the performance of a bipolar electrolysis/electrocoagulation reactor designed to enhance the sludge dewaterability. The reactor was 15 L in volume, with two series of plates used in it; Ti/RuO2 plates for the electrolysis of the sludge, and also aluminum and iron plates for electrocoagulation process. The dewaterability of the sludge was determined in terms of its capillary suction time (CST) and specific resistance to filtration (SRF), while the degree of sludge disintegration was determined based on the value of degree of sludge disintegration (DDSCOD). The maximum reduction in CST and SRF was observed at a detention time of 20 min and a voltage of 30 V. However, increasing of both detention time and voltage significantly increased the values of CST and SRF even to an extent that they both exceeded those of the untreated sludge. The optimal degree of sludge disintegration achieved by the present study was 2.5%, which was also achieved at a detention time of 20 min and a voltage of 30 V. As reported previously, increased DDSCOD values led to increasing CST and SRF values, due primarily to the disruption of the sludge flocs. According to the results from the present study, it can be concluded that simultaneous application of electrocoagulation and electrolysis is effective in enhancing the sludge dewaterability, because electrocoagulation helps to achieve a higher degree of sludge disintegration while maintaining the desired sludge dewaterability.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号