首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Factors influencing on the bioaccessibility of polybrominated diphenyl ethers in size-specific dust from air conditioner filters
Authors:Yingxin Yu  Dan Yang  Xinxin Wang  Ningbao Huang  Xinyu Zhang  Dongping Zhang  Jiamo Fu
Institution:1. Institute of Environmental Pollution and Health, School of Environmental and Contaminant Engineering, Shanghai University, Shanghai 200444, PR China;2. State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, PR China
Abstract:Size-specific concentrations and bioaccessibility of polybrominated diphenyl ethers (PBDEs) in dust from air conditioner filters were measured, and the factors influencing the PBDE bioaccessibility were determined. Generally, the PBDE concentrations increased with decreasing dust particle size, and BDE209 (deca-BDE) was generally the predominant congener. The bioaccessibility ranged from 20.3% to 50.8% for tri- to hepta-BDEs, and from 5.1% to 13.9% for BDE209 in dust fractions of varied particle size. The bioaccessibility of most PBDE congeners decreased with increasing dust particle size. The way of being of PBDE (adsorbed to dust surface or incorporated into polymers) in dust significantly influenced the bioaccessibility. There was a significant negative correlation between the tri- to hepta-BDE bioaccessibility and organic matter (OM) contents in dust. Furthermore, tri- to hepta-BDE bioaccessibility increased with increasing polarity of OMs, while with decreasing aromaticity of OMs. The tri- to hepta-BDE bioaccessibility significantly positively correlated with the surface areas and pore volumes of dust. Using multiple linear regression analysis, it was found that the OM contents and pore volumes of dust were the most important factors to influence the tri- to hepta-BDE bioaccessibility and they could be used to estimate the bioaccessibility of tri- to hepta-BDEs according to the following equation: bioaccessibility (%) = 45.05 − 0.49 × OM% + 1.79 × pore volume. However, BDE209 bioaccessibility did not correlate to any of these factors.
Keywords:GC/MS  gas chromatography/mass spectrometry  HOCs  hydrophobic organic compounds  NCI  negative chemical ionization  OMs  organic matters  POPs  persistent organic pollutants  PBDEs  polybrominated diphenyl ethers  PAHs  polycyclic aromatic hydrocarbons  SEM  scanning electron microscope
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号