Application of an ELISA for PCB 118 to the screening of dioxin-like PCBs in retail fish |
| |
Authors: | Tsutsumi Tomoaki Amakura Yoshiaki Okuyama Akira Tanioka Youhei Sakata Kazuto Sasaki Kumiko Maitani Tamio |
| |
Institution: | Division of Foods, National Institute of Health Sciences, Kamiyoga 1-18-1, Setagaya-ku, Tokyo 158-8501, Japan. tutumi@nihs.go.jp |
| |
Abstract: | A commercially available enzyme-linked immunosorbent assay (ELISA) kit was evaluated for the determination of toxic equivalents (TEQs) of dioxin-like polychlorinated biphenyls (PCBs) in retail fish. The ELISA was highly specific for 2,3',4,4',5-pentachlorobiphenyl (PCB 118), which is generally the most abundant dioxin-like PCB isomer found in fish. The quantitative limit of the ELISA (using 3,3',4'-trichloro-4-methoxybiphenyl as a surrogate standard for PCB 118) was 10 ng ml(-1) (125 pg assay(-1)) in the standard curve, corresponding to 50 pg PCB 118 g(-1) in the tested sample. Good recoveries of PCB 118 (78.7-112.3%) were obtained for spiked purified fish extracts according to the ELISA. Good linearity was also obtained in dilution tests using purified fish extracts. No significant interference of the matrix was observed in the ELISA when this purification procedure was used. Recovery tests in which PCB 118 was added to fish samples also resulted in acceptable recoveries (60.2-82.3%) in the ELISA following purification. The ELISA results for fish samples correlated well with the TEQ concentrations of dioxin-like PCBs obtained by high-resolution gas chromatography/high-resolution mass spectrometry (r = 0.92, n = 26). These data indicate that the ELISA kit is suitable for screening retail fish for the TEQs of dioxin-like PCBs. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|