首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A New Audit Technique for EPA Method 25
Authors:R K M Jayanty  J A Sokash  G B Howe  R G Fuerst  T J Logan  M R Midgett
Institution:1. Research Triangle Institute , Research Triangle Park , North Carolina , USA;2. U.S. Environmental Protection Agency , Research Triangle Park , North Carolina , USA
Abstract:A simple, inexpensive, and accurate technique for evaluating or auditing the sampling, recovery, and analytical phases of EPA Source Reference Method 25 has been developed. The technique involves spiking a U-shaped stainless steel cartridge containing Tenax® with known quantities of selected organic compounds and thermally desorbing them at temperatures from 160°C to 180°C to generate organic vapors quantitatively. The major advantages of this technique are that no other measurement methods can be used to determine the generated organic concentrations in lieu of Method 25; and that the cartridge can easily be taken to the field for evaluation. The organic compounds generated in test runs are collected and analyzed using the Method 25 procedure. The generation of organics is quantitative and recoveries were found to be 100 ± 10%. The time required for desorption of the majority of organics is generally less than forty-five minutes at a flow rate of 100 mL/min; however, based on laboratory experience the recommended sampling time is sixty minutes. These spiked cartridges are stable at room temperature over a two-month period. Results of interlaboratory studies showed close agreement with the expected concentrations based on calculations from the mass loadings and sample volumes.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号