Results of Field Measurements of Industrial Particulate Sources and Electrostatic Precipitator Performance
Authors:Joseph D McCain  John P Gooch  Wallace B Smith
Institution:Southern Research Institute , Birmingham , Alabama , USA
Abstract:This paper presents results of source size distribution measurements over the size range from 0.1 μm to 5 μm for six classes of particulate sources and fractional efficiency measurements on five full scale electrostatic precipitators and one pilot scale precipitator. The precipitators all showed moderately high to high particulate collection efficiencies for particles having diameters larger than a few micrometers or smaller than a few hundredths of a micrometer and a minimum in collection efficiency for particles having diameters of a few tenths of a micrometer.