首页 | 本学科首页   官方微博 | 高级检索  
     检索      


The implosion of the Calgary General Hospital: ambient air quality issues
Authors:Stefani Dennis  Wardman Dennis  Lambert Timothy
Institution:Risk Assessment and Management Section, Environmental Health, Calgary Health Region, Alberta, Canada. dennis.stefani@calgaryhealthregion.ca
Abstract:This paper discusses the implosion of a large inner-city hospital in Calgary, Alberta, Canada, on October 4, 1998. Stationary and mobile air monitoring conducted after the implosion indicated there were several short-term air quality issues, including significant temporal increases in total suspended particles, particulate matter (PM) with aerodynamic diameter less than or equal to 10 microm (PM10), PM with aerodynamic diameter less than or equal to 2.5 microm (PM2.5), asbestos, and airborne and settled lead. In addition, the implosion created a dust cloud that traveled much further than expected, out to 20 km. The ability of an implosion to effectively aerosolize building materials requires the removal of all friable and nonfriable forms of asbestos and all Pb-containing painted surfaces during pre-implosion preparatory work. Public advisories to mitigate personal exposure and indoor migration of the implosion dust cloud constituents should extend to 10 or 20 km around an implosion site. These findings point to a number of complex and problematic issues regarding implosions and safeguarding human health and suggest that implosions in metropolitan areas should be prohibited. Further work to characterize the public health risks of conventional versus implosion demolition is recommended.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号