首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Estimates of AOT ozone indices from time-integrated ozone data and hourly air temperature measurements in southwest Sweden
Authors:K Piikki  J Klingberg  G Pihl Karlsson  PE Karlsson  H Pleijel  
Institution:aUniversity of Skövde, School of Life Sciences, P.O. Box 408, SE-541 28 Skövde, Sweden;bUniversity of Gothenburg, Department of Plant and Environmental Sciences, P.O. Box 461, SE-405 30 Göteborg, Sweden;cIVL Swedish Environmental Research Institute Ltd., P.O. Box 5302, SE-400 14 Göteborg, Sweden
Abstract:Surface ozone concentration and surface air temperature was measured hourly at three coastal sites, four low elevation inland sites and two high elevation inland sites in southwestern Sweden. Diurnal ozone concentration range (DOR) and diurnal temperature range (DTR) were strongly correlated, both spatially and temporally, most likely because both depended on atmospheric stability. Accumulated ozone exposure above a threshold concentration of x nmol mol1 (AOTx) was estimated from time-integrated ozone concentration (as from diffusive sampling) and measures of ozone concentration variability. Two methods both estimated 24-h AOTx with high accuracy (modelling efficiencies >90% for x ≤ 40 nmol mol−1). Daytime (08:00–20:00) AOTx could not be equally well estimated. Estimates were better for lower AOT thresholds. Diffusive ozone concentration sampling, combined with hourly temperature monitoring, could be a valuable complement to ozone concentration monitoring with continuous instruments.
Keywords:AOT40  Ozone  Ozone index  Diffusive sampler  Temperature
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏