首页 | 本学科首页   官方微博 | 高级检索  
     检索      

煤化工废水反渗透处理系统的运行效果及膜污染分析
引用本文:李晨璐,郭雅妮,李玉林,杨继广,康赛,郑利兵,魏源送.煤化工废水反渗透处理系统的运行效果及膜污染分析[J].环境科学学报,2021,41(9):3464-3477.
作者姓名:李晨璐  郭雅妮  李玉林  杨继广  康赛  郑利兵  魏源送
作者单位:西安工程大学环境与化学工程学院,西安710048;中国科学院生态环境研究中心,水污染控制实验室,北京100085;西安工程大学环境与化学工程学院,西安710048;国家能源集团神华新疆化工有限公司,乌鲁木齐831404;济宁波塞顿环保技术有限公司,济宁272400;中国科学院生态环境研究中心,水污染控制实验室,北京100085
基金项目:中国-斯里兰卡基金委联合基金(No.21861142020);中国-斯里兰卡水技术研究与示范联合中心项目
摘    要:针对煤化工废水反渗透(RO)膜处理系统夏季严重污堵的问题,本研究以实际某煤化工污水处理厂一级两段式RO系统为考察对象,分析了系统运行效能及膜污染特征.研究发现,生化段稳定地实现了有机物的削减,离子交换树脂进一步保障了产水的脱盐率,促进实现高水回收率,是煤化工废水零排放的重要保障.但对膜系统而言,脱盐及有机物去除的主要负荷集中在RO过程,一段/二段RO脱盐率分别为94.16%和96.16%,COD去除率分别为68.12%和87.4%;相对进水,一段RO有机物浓缩了9倍,二段RO盐浓缩了5倍.因此,两段膜过程都出现显著的膜污染,一段RO以有机-微生物-硅污染为主,形成致密的污染层,由进口到出口逐渐增厚,主要为蛋白质、多糖、腐殖酸;二段RO以Ca、Mg等的无机结垢为主,污染层结构相对松散,由进口到出口片状结晶逐渐增大.因此,预处理工艺的稳定运行及对污染物的去除以减轻RO过程的污染负荷是膜污染控制的关键;同时,针对RO系统中膜污染分布特征,制定杀菌、阻垢和化学清洗等膜污染控制策略以防止形成微生物抗性及"清洗剂抗性"具有重要意义.

关 键 词:膜污染  反渗透  煤化工废水  复合污染  预处理
收稿时间:2020/12/17 0:00:00
修稿时间:2021/1/14 0:00:00

Study of the operating efficiency and membrane fouling of reverse osmosis process in coal chemical wastewater treatment
LI Chenlu,GUO Yani,LI Yulin,YANG Jiguang,KANG Sai,ZHENG Libing,WEI Yuansong.Study of the operating efficiency and membrane fouling of reverse osmosis process in coal chemical wastewater treatment[J].Acta Scientiae Circumstantiae,2021,41(9):3464-3477.
Authors:LI Chenlu  GUO Yani  LI Yulin  YANG Jiguang  KANG Sai  ZHENG Libing  WEI Yuansong
Institution:1. College of Environmental and Chemical Engineering, Xi''an Polytechnic University, Xi''an 710048;2. Department of Water Pollution Control Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085;Shenhua Xinjiang Chemical Co., Ltd., Urumqi 831404;Jining Poseidon Environmental Protection Technology Co., Ltd., Jining 272400
Abstract:Membrane fouling is a key issue of reverse osmosis (RO) in treating coal chemical industry wastewater. Therefore, a full-scale two-stage RO process was systematically analyzed in terms of operation efficiency and the membrane fouling in a coal chemical wastewater treatment plant in China. It was found that the A/O process had stable pretreatment performance for organic matters (OMs) removal; the ion exchange processes guaranteed the removal of ions, which promoted the higher water reuse rate. They ware key processes for zero liquid discharge (ZLD) of coal chemical wastewater. However, most of the OMs and salt removal load were happened in RO in membrane process, which offer salt rejection and COD removal rate of 94.16%, 96.16% and 68.12%, 87.4% in the first-stage RO and second-stage RO, respectively. Meanwhile, compared to the feedwater, the OMs were 9 times concentrated in the first-stage RO, whereas the salts were 5 times concentrated in the second-stage RO, respectively. Therefore, membrane fouling appeared in both two stage membrane processes. Organic fouling, biofouling, combined with Si fouling were the main mechanism for the first-stage RO with a formation of dense foulants layer, which became gradually thicker from inlet to outlet. The main organic components were identified as protein, polysaccharide and humic acid. However, mineral scaling was the main mechanism for the second-stage RO process with a main component of Ca and Mg. The foulants layer was relatively loose, and crystal size increased along with the flow direction. Therefore, the selection of pretreatment process and its stable performance was essential to alleviate the pollutants load of RO. And it is recommended to improve the sterilization, scale inhibition and chemical cleaning strategies in consider of the distribution of fouling in RO to avoid the appearance of microbial resistance and cleaning tolerance.
Keywords:membrane fouling  reverse osmosis  coal chemical wastewater  combined fouling  pretreatment
本文献已被 万方数据 等数据库收录!
点击此处可从《环境科学学报》浏览原始摘要信息
点击此处可从《环境科学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号