烟塔合一排放参数试验及特征
引用本文:陈义珍,赵 丹,柴发合,史晓红,王振奎,王慧婷.烟塔合一排放参数试验及特征[J].环境科学研究,2010,23(5):543-547.
作者姓名:陈义珍  赵 丹  柴发合  史晓红  王振奎  王慧婷
作者单位:1.中国环境科学研究院, 北京 100012
基金项目:中央级公益性科研院所基本科研业务专项,国家高技术研究发展计划(863计划) 
摘    要:在电厂典型工况条件下,测试烟塔排放口及塔体内部混合烟气的流速、温度、气压和相对湿度等参数的分布. 结果表明:在烟塔排放口和塔体内部,混合烟气各参数的分布均是非均匀的. 烟塔排放口处各参数水平分布均为中心处高、边缘处低;2月17,21和22日烟塔排放口处混合烟气的平均流速分别为2.8,3.1和2.9 m/s,总平均流速为2.9 m/s;3 d平均温度分别为13.1,13.4和13.2 ℃,总平均温度为13.2 ℃;3 d平均相对湿度分别为94.1%,87.8%和90.3%,总平均相对湿度为90.7%. 塔体内部混合烟气各参数垂直分布规律为:温度、气压和相对湿度均为烟塔中心处高、边缘处低,但流速分布不同,在塔体上部流速分布呈中心处高、边缘处低,而下部则相反. 

关 键 词:火电厂    烟塔合一    排放参数    特征
收稿时间:2010/1/11 0:00:00
修稿时间:2010/2/22 0:00:00

Emission Parameters Experimentation and Characteristics of Cooling Towers with Flue Gas Injection
CHEN Yi-zhen,ZHAO Dan,CHAI Fa-he,SHI Xiao-hong,WANG Zhen-kui and WANG Hui-ting.Emission Parameters Experimentation and Characteristics of Cooling Towers with Flue Gas Injection[J].Research of Environmental Sciences,2010,23(5):543-547.
Authors:CHEN Yi-zhen  ZHAO Dan  CHAI Fa-he  SHI Xiao-hong  WANG Zhen-kui and WANG Hui-ting
Institution:1.Chinese Research Academy of Environmental Sciences, Bejing 100012, China2.College of Population Resource and Environment, Shandong Normal University, Jinan 250014, China3.Guohua Sanhe Power Plant, Sanhe 065201, China
Abstract:The distribution of emission parameters such as velocity, temperature, atmospheric pressure and humidity in the inside and outlet of a cooling tower under typical working conditions in a thermal power plant were measured. The results show that the distributions are non-uniform. At the outlet of the cooling tower, all the emission parameters at the edge were low, while the parameter values at the center were high. During three experiments, the average velocities were 2.8, 3.1, and 2.9 m/s respectively, while the overall average was 2.9 m/s. The average temperatures were 13.1, 13.4, and 13.2 ℃ respectively, while the overall average was 13.2 ℃. The average humidities were 94.1%, 87.8%, and 90.3% respectively, while the overall average was 90.7%. Generally speaking, on the upside of the cooling tower, all the emission parameters at the edge were low, while the parameter values of the center were high. On the downside of the cooling tower, the temperature, atmospheric pressure and humidity at the edge were low, while the velocity at the edge was high. 
Keywords:thermal power plant  cooling towers with flue gas injection  emission parameters  characteristics
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《环境科学研究》浏览原始摘要信息
点击此处可从《环境科学研究》下载免费的PDF全文