光离子检测器测定大气中溴甲烷
引用本文:钟晋贤,刘晔.光离子检测器测定大气中溴甲烷[J].环境科学,1996(2):64-65.
作者姓名:钟晋贤  刘晔
作者单位:中国科学院生态环境研究中心
摘    要:用Tenax作为吸附剂捕集大气中的痕量溴甲烷,用气相色谱法和光离子检测器,对其进行检测,相对偏差为0.0521,最小检测限为10pg。室内外大气中的浓度分别为24×10(-12)(V/V)和77.4×10(-12)(V/V),污染在10(-11)(V/V)水平。

关 键 词:溴甲烷,气相色谱,光离子检测器
收稿时间:1995/7/10 0:00:00

Determination of Atmospheric Methyl Bromide by Photoionization Detector
Zhong Jinxian and Liu Ye.Determination of Atmospheric Methyl Bromide by Photoionization Detector[J].Chinese Journal of Environmental Science,1996(2):64-65.
Authors:Zhong Jinxian and Liu Ye
Institution:Research Center for Eec-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085;Research Center for Eec-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085
Abstract:tmospheric CH3Br was trapped by Tenax adsorbent and was determined by gas chromatography with photoionization detector. The CH3Br concentrations in indoor and outdoor are 24 X 10-12 (V/V) and 77. 4 X 10-12 (V/V).The standard deviation and detection limit for the method are 0. 0521, 10 pg respectively. The level of CH3Br pollutions is 10--11 (V/V)
Keywords:ethyl bromide  GC  photoionization detector    
本文献已被 CNKI 等数据库收录!