天津市夏季蜂窝状溶蚀器涂层溶液浓度确定的实验研究
引用本文:张诗建,姬亚芹,张雷波,赵雪艳,朱振宇,杨文.天津市夏季蜂窝状溶蚀器涂层溶液浓度确定的实验研究[J].环境科学,2014,35(8):2878-2882.
作者姓名:张诗建  姬亚芹  张雷波  赵雪艳  朱振宇  杨文
作者单位:南开大学环境科学与工程学院, 天津 300071;南开大学环境科学与工程学院, 天津 300071;南开大学环境科学与工程学院, 天津 300071;中国环境科学研究院, 北京 100012;南开大学环境科学与工程学院, 天津 300071;中国环境科学研究院, 北京 100012
基金项目:环境保护公益性行业科研专项(201009007)
摘    要:于2013年7月1日~8月31日,在天津市南开大学理化楼楼顶,采用蜂窝状溶蚀器进行了溶蚀器涂层溶液最适浓度的探究实验.结果表明,在天津夏季,蜂窝状溶蚀器的碳酸钠涂层溶液最适浓度为3%,柠檬酸涂层溶液最适浓度为6%.含有溶蚀器系统的颗粒物采样法与传统采样法对比发现,含蜂窝状溶蚀器的采样系统所得到的PM2.5样品浓度有86%低于传统方法所得到的PM2.5样品浓度,其原因主要为1酸/碱性气体被去除,使其无法与富集在采样膜上的颗粒物发生反应,也无法吸附到颗粒物上;2溶蚀器系统采样过程中,部分颗粒物被捕集到溶蚀器上;3酸/碱性气体被去除,导致气-粒平衡被打破,部分颗粒物组分向气态转化.

关 键 词:细颗粒物(PM2.5)  蜂窝状溶蚀器  涂层溶液  酸/碱性气体  最适浓度
收稿时间:1/2/2014 12:00:00 AM
修稿时间:2014/2/27 0:00:00

Determining the Concentration of Coating Solution Attaching to Honeycomb Denuder in Summer in Tianjin
ZHANG Shi-jian,JI Ya-qin,ZHANG Lei-bo,ZHAO Xue-yan,ZHU Zhen-yu and YANG Wen.Determining the Concentration of Coating Solution Attaching to Honeycomb Denuder in Summer in Tianjin[J].Chinese Journal of Environmental Science,2014,35(8):2878-2882.
Authors:ZHANG Shi-jian  JI Ya-qin  ZHANG Lei-bo  ZHAO Xue-yan  ZHU Zhen-yu and YANG Wen
Institution:College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China;College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China;College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China;Chinese Research Academy of Environmental Sciences, Beijing 100012, China;College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China;Chinese Research Academy of Environmental Sciences, Beijing 100012, China
Abstract:The study on determining the concentration of coating solution attaching to honeycomb denuder was conducted, from 1 July to 31 August, 2013, at the roof of Lihua building at Nankai University in Tianjin. The results of experiment showed that the optimized concentration of sodium carbonate coated on the honeycomb denuder was 3%, and the optimized concentration of citric acid was 6%. The contrast sampling results of PM2.5 between honeycomb denuder system and conventional method showed that 86% of the concentration of PM2.5 samples obtained by honeycomb denuder system were less than those obtained by conventional method, the main reasons may include that: 1 the majority of acid/alkaline gases were removed, so they could neither react with the enriched particles on the sampling membrane nor be adsorbed on particles; 2 parts of the particles were captured by the denuder during sampling; 3 the removal of acid/alkaline gases disturbed the state of equilibrium between gas- and particle-phases which may lead to the volatilization of some particles.
Keywords:PM2  5  honeycomb denuder  coating solution  acid/alkaline gases  optimal concentration