High-performance size exclusion chromatography with a multi-wavelength absorbance detector study on dissolved organic matter characterisation along a water distribution system
Authors:Huiping Huang  Emma Sawade  David Cook  Christopher WK Chow  Mary Drikas  Bo Jin
Institution:1 School of Chemical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia;2 School of Earth and Environmental Sciences, The University of Adelaide, Adelaide, SA 5005, Australia;3 Australian Water Quality Centre, SA Water Corporation, 250 Victoria Square, Adelaide, SA 5100, Australia
Abstract:This study examined the associations between dissolved organic matter (DOM) characteristics and potential nitrification occurrence in the presence of chloramine along a drinking water distribution system. High-performance size exclusion chromatography (HPSEC) coupled with a multiple wavelength detector (200–280 nm) was employed to characterise DOM by molecular weight distribution, bacterial activity was analysed using flow cytometry, and a package of simple analytical tools, such as dissolved organic carbon, absorbance at 254 nm, nitrate, nitrite, ammonia and total disinfectant residual were also applied and their applicability to indicate water quality changes in distribution systems were also evaluated. Results showed that multi-wavelength HPSEC analysis was useful to provide information about DOM character while changes in molecule weight profiles at wavelengths less than 230 nm were also able to be related to other water quality parameters. Correct selection of the UV wavelengths can be an important factor for providing appropriate indicators associated with different DOM compositions. DOM molecular weight in the range of 0.2–0.5 kDa measured at 210 nm correlated positively with oxidised nitrogen concentration (r = 0.99), and the concentrations of active bacterial cells in the distribution system (r = 0.85). Our study also showed that the changes of DOM character and bacterial cells were significant in those sampling points that had decreases in total disinfectant residual. HPSEC-UV measured at 210 nm and flow cytometry can detect the changes of low molecular weight of DOM and bacterial levels, respectively, when nitrification occurred within the chloraminated distribution system.
Keywords:HPSEC-UV  Distribution system  DOM  Sum of nitrate and nitrite concentration
本文献已被 CNKI 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号