Effect of spectral resolution on the measurement of monoaromatic
hydrocarbons by DOAS |
| |
Authors: | PENG Fumin XIE Pinhu ZHANG Yinghu ZHU Yanwu SI Fuqi LIU Wenqing and WANG Junde |
| |
Institution: | 1. Key Laboratory of Environmental Optical and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China;College of Chemistry and Chemical Engineering, Anhui University, Hefei 230039, China 2. Key Laboratory of Environmental Optical and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China 3. Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China |
| |
Abstract: | The excellent response characteristics and detection sensitivity with much lower operational cost and the capability to discriminate between the isomer of some monoaromatic hydrocarbons (MAHCs) make differential optical absorption spectroscopy (DOAS) a powerful tool to trace concentration variation of MAHCs. But due to the similarity in chemical structure, those MAHCs have the similar overlapped characteristic absorption structures, which make the selection of instrumental parameter critical to the accurate detection of MAHCs. Firstly, the spectral resolution used in DOAS system determines the nonlinear absorption of O2 and the mass dependence of characteristic absorption structure; thereby it determines the effect of elimination error of O2 absorption in the atmospheric spectra for the detection of MAHCs. Secondly, spectral resolution determines the differential absorption characteristics of twelve MAHCs representing major constituents in technical solvents used in the automobile industry and the interference of spectral overlapping. Thirdly, the spectral resolution determines the sensitivity, time resolution and linear range. So the spectral resolution range with the best ratio of signal to noise is used to determine the most suitable spectral resolution range, as well as the spectral resolution range that ensure the characteristic absorption structure of MAHCs and the minimization of O2 absorption interference. Finally, 0. 15-0. 16 nm (FWHM: full width at half maximum) is assumed to be closest to the optimum spectral resolution and it is confirmed by the results of practical measurement of MAHCs by DOAS. |
| |
Keywords: | differential optical absorption spectroscopy (DOAS) monoaromatic hydrocarbons (MAHCs) spectral resolution characteristic absorption structure |
本文献已被 维普 万方数据 ScienceDirect PubMed 等数据库收录! |
| 点击此处可从《环境科学学报(英文版)》浏览原始摘要信息 |
| 点击此处可从《环境科学学报(英文版)》下载免费的PDF全文 |
|