Iron stability in drinking water distribution systems in a city of China
作者姓名:NIU Zhang-bin  WANG Yang  ZHANG Xiao-jian  HE Wen-jie  HAN Hong-  YIN Pei-jun
作者单位:[1]Department of Environment Science and Technology, Tsinghua University, Beijing 100084, China [2]Tianjin Water Works Limited Company, Tianjin 300000, China
基金项目:中国科学院资助项目;国家科技攻关项目
摘    要:A field study on the estimation and analysis of iron stability in drinking water distribution system was carried out in a city of China. The stability of iron ion was estimated by pC-pH figure. It was found that iron ion was unstable, with a high Fe (OH)3 precipitation tendency and obvious increase in turbidity. The outer layer of the corrosion scale was compact, while the inner core was porous. The main composition of the scale was iron, and the possible compound constitutes of the outer scale were α-FeOH, γ-FeOOH, α-Fe2O3, γ-F2O3, FeCl3, while the inner were Fe3O4, FeCl2, FeCO3. According to the characteristics of the corrosion scale, it was thought that the main reason for iron instability was iron release from corrosion scale. Many factors such as pipe materials, dissolved oxygen and chlorine residual affect iron release. Generally, higher iron release occurred with lower dissolved oxygen or chlorine residual concentration, while lower iron release occurred with higher dissolved oxygen or chlorine residual concentration. The reason was considered that the passivated out layer of scale of ferric oxide was broken down by reductive reaction in a condition of low oxidants concentration, which would result more rapid corrosion of the nine and red water phenomenon.

关 键 词:中国  离子稳定性  水资源  水分布系统  饮用水  溶解氧
文章编号:1001-0742(2006)01-0040-07
收稿时间:2005-05-16
修稿时间:2005-08-23

Iron stability in drinking water distribution systems in a city of China
NIU Zhang-bin,WANG Yang,ZHANG Xiao-jian,HE Wen-jie,HAN Hong-,YIN Pei-jun.Iron stability in drinking water distribution systems in a city of China[J].Journal of Environmental Sciences,2006,18(1):40-46.
Authors:NIU Zhang-bin  WANG Yang  ZHANG Xiao-jian  HE Wen-jie  HAN Hong-da and YIN Pei-jun
Institution:1. Department of Environment Science and Technology, Tsinghua University, Beijing 100084, China
2. Tianjin Water Works Limited Company, Tianjin 300000, China
Abstract:A field study on the estimation and analysis of iron stability in drinking water distribution system was carried out in a city of China. The stability of iron ion was estimated by pC-pH figure. It was found that iron ion was unstable, with a high Fe(OH)
Keywords:chlorine residual  corrosion scale  dissolved oxygen  drinking water distribution systems  iron release  iron stability