离子色谱法测定废水中硫化物
引用本文:付友生,姜秋俚.离子色谱法测定废水中硫化物[J].环境保护科学,2013,39(5):51-53,66.
作者姓名:付友生  姜秋俚
作者单位:辽宁省环境监测实验中心,辽宁沈阳,110031
基金项目:辽河流域水环境安全监控与监测体系建设
摘    要:用蒸馏法对废水进行预处理,磷酸对样品进行酸化使其释放硫化氢,氢氧化钠溶液进行吸收,离子色谱法进行测定。该方法检出限为0.003mg/L,在0.03~10mg/L浓度范围内线性良好,相对标准偏差分别为7.40%、4.31%,实际样品加标回收率在92.0%~117.4%之间。离子色谱法与化学法间相对偏差为4.58%~13.3%。该方法操作简便,灵敏度高,精确度和准确度高,便于推广,适合废水中硫化物的测定。

关 键 词:离子色谱法  废水  硫化物

Determination of Sulfide in Wastewater by Ion Chromatography
Abstract:Based on determination of sulfides in wastewater by ion chromatography,wastewater was pretreated by using distillation of which wastewater samples were acidified with phosphoric acid to release hydrogen sulfide,absorbed with sodium hydroxide solution,then determined by ion chromatography.The method detection limit is 0.003 mg/L,the good linear relationship is in the range of 0.03~10 mg/L,the relative standard deviation is 7.40% and 4.31%,respectively,the addition standard recovery of actual sample is 92.0%~117.4%.Relative deviation of ion chromatography method and chemical method is 4.58%~13.3%.This method is easy to spread for determination of sulfide in the wastewater owe to its easy operation,high sensitivity,precision and accuracy.
Keywords:Ion Chromatography  Wastewater  Sulfide