4-氨基安替比林直接分光光度法测定废水中挥发酚方法改进
引用本文:杨佳艳.4-氨基安替比林直接分光光度法测定废水中挥发酚方法改进[J].环境科学与管理,2011,36(8):143-146.
作者姓名:杨佳艳
作者单位:上海市普陀区环境监测站,上海,200062
摘    要:对4-氨基安提比林直接分光光度法测定废水中挥发酚方法提出改进,用过硫酸钾取代铁氰化钾作为氧化剂使反应进行完全,显色反应的稳定性、重现性和准确性均较好。方法的最低检出限浓度为0.006 mg/L,测定下限为0.024 mg/L符合标准方法的要求。

关 键 词:过硫酸钾  4-氨基安提比林  挥发酚

Improvement of Determining Volatile Phenol in Wastewater by Using 4 -Aminoantioyrine Direct Colorimetric Method
Yang Jiayan.Improvement of Determining Volatile Phenol in Wastewater by Using 4 -Aminoantioyrine Direct Colorimetric Method[J].Environmental Science and Management,2011,36(8):143-146.
Authors:Yang Jiayan
Institution:Yang Jiayan(Shanghai Putuo Environmental Monitoring Station,Shanghai 200062,China)
Abstract:This study improves the 4 -Aminoantipyrine direct spectrometric method to measure volatile phenol in'wastewater by using potassium persulfate instead of potassium ferricyanide as oxidant. The color reaction become more complete for the stabil-ity, reprodu
Keywords:potassium persulfate  4 - aminoantipyrine  volatile phenol