燃煤锅炉烟气中一氧化氮排放浓度测量的不确定度评定
引用本文:李健,李永亮,牟学军,邵茂华.燃煤锅炉烟气中一氧化氮排放浓度测量的不确定度评定[J].内蒙古环境科学,2011(9):183-184.
作者姓名:李健  李永亮  牟学军  邵茂华
作者单位:佳木斯市环境保护监测站,黑龙江154004
摘    要:根据《测量不确定度评定与表示》(JJF1059-1999),对燃煤锅炉烟气中一氧化氮排放浓度的测量不确定度进行评定。对废气监测领域不确定度评定具有现实意义。

关 键 词:一氧化氮  测量  不确定度

Uncertainty Assessment for the Measure of Nitric Oxide in Coal-fired Boiler Flue Gas
Li Jian,Li Yongliang,Mou Xuejun,Shao Maohua.Uncertainty Assessment for the Measure of Nitric Oxide in Coal-fired Boiler Flue Gas[J].Inner Mongolia Environmental Protection,2011(9):183-184.
Authors:Li Jian  Li Yongliang  Mou Xuejun  Shao Maohua
Institution:(Jiamusi Environmental Monitoring Station,Hei Longjiang 154004)
Abstract:Analysis of the uncertainty in measure of Nitric Oxide in Coal-fired boiler flue gas is according to the 'Evaluation and Expression of Uncertainty in Measurement'(JJF1059-1997).And is instructive to assess for waste gas monitoring.
Keywords:nitric oxide  measure  uncertainty