首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of 27 pharmaceuticals and personal care products (PPCPs) in water: The benefit of isotope dilution
Authors:Xueqi Fan  Jie Gao  Wenchao Li  Jun Huang  Gang Yu
Institution:1. State Key Joint Laboratory of Environment Simulation and Pollution Control (SKJLESPC), Beijing Key Laboratory for Emerging Organic Contaminants Control (BKLEOC), School of Environment, Tsinghua University, Beijing 100084, China2. CSD IDEA (Beijing) Environment Test & Analysis Co., Ltd., Beijing 100192, China
Abstract: ? Isotope dilution method was developed for the determination of 27 PPCPs in water. ? The established method was successfully applied to different types of water samples. ? The correction effect of corresponding 27 ILSs over 70 d was investigated. ? Benefit of isotopic dilution method was illustrated for three examples. Pharmaceuticals and personal care products (PPCPs) are a unique group of emerging and non-persistent contaminants. In this study, 27 PPCPs in various water samples were extracted by solid phase extraction (SPE), and determined by isotope dilution method using liquid chromatography coupled to tandem triple quadruple mass spectrometer (LC-MS/MS). A total of 27 isotopically labeled standards (ILSs) were applied to correct the concentration of PPCPs in spiked ultrapure water, drinking water, river, effluent and influent sewage. The corrected recoveries were 73%–122% with the relative standard deviation (RSD)<16%, except for acetaminophen. The matrix effect for all kinds of water samples was<22% and the method quantitation limits (MQLs) were 0.45–8.6 ng/L. The developed method was successfully applied on environmental water samples. The SPE extracts of spiked ultrapure water, drinking water, river and wastewater effluent were stored for 70 days, and the ILSs-corrected recoveries of 27 PPCPs were obtained to evaluate the correction ability of ILSs in the presence of variety interferences. The recoveries of 27 PPCPs over 70 days were within the scope of 72%–140% with the recovery variation<37% in all cases. The isotope dilution method seems to be of benefit when the extract has to be stored for long time before the instrument analysis.
Keywords:Pharmaceuticals and personal care products (PPCPs)  Isotopically labeled standard (ILSs)  Water  Solid-phase extraction (SPE)  LC-MS/MS  
点击此处可从《Frontiers of Environmental Science & Engineering》浏览原始摘要信息
点击此处可从《Frontiers of Environmental Science & Engineering》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号