摘    要:建立了电感耦合等离子体质谱法(ICP-MS)测定饮料中的铀.对不同基质的饮料进行了前处理方法的摸索,从精密度和回收率考察了方法的准确性,相对标准偏差(RSD)为1.67%-8.21%(n=6),加标回收率为96.0%-109.0%,方法检出限为0.010μg·l~(-1),方法准确可靠.

关 键 词:电感耦合等离子体质谱(ICP-MS)    饮料.

DETERMINATION OF URANIUM IN SOFT DRINK BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
YANG Yan-li,ZHOU An-fei,CHEN Guang.DETERMINATION OF URANIUM IN SOFT DRINK BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY[J].Environmental Chemistry,2009,28(6).
Authors:YANG Yan-li  ZHOU An-fei  CHEN Guang
Abstract:The method for determination of uranium in soft drinking by inductively coupled plasma mass spectrometry (ICP-MS) was established. Sample preparation for different soft drink was investigated and precision and recovery results were evaluated. The relative standard deviations (RSDs) were 1.67%-8.21% (n =6), the spiked recovery were 96.0%-109.0% and the detection limit was 0.010μg ·l~(-1). The method was accurate and reliable.
Keywords:ICP-MS  uranium  soft drink  