首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Within-room and within-building temporal and spatial variations in concentrations of polybrominated diphenyl ethers (PBDEs) in indoor dust
Institution:1. State Key Laboratory of Organic Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, 510640, China;2. University of Chinese Academy of Sciences, Beijing, 100049, China;3. College of Chemical Engineering, Guangdong University of Petrochemical Technology, Maoming, 525000, China;4. Key Laboratory of Reservoir Aquatic Environment of CAS, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, 400714, China;1. Department of the Built Environment, Aalborg University, A. C. Meyers Vænge 15, København SV, DK-2450, Denmark;2. National Research Centre for the Working Environment, Lersø Parkalle 105, København Ø, DK-2100, Denmark;1. Department of Fisheries and Environmental Sciences,, Faculty of Natural Resource, University of Tehran, Karaj, Iran;2. Department of Biology & Centre for Advanced Research in Environmental Genomics, University of Ottawa, Ottawa, Ontario, Canada;3. Department of Biology, Islamic Azad University, Karaj Branch, Karaj, Iran;4. Department of Biology, Islamic Azad University, Borujerd Branch, Borujerd, Iran;1. State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China;2. University of Chinese Academy of Sciences, Beijing 100049, China;3. Shenzhen Center for Disease Control and Prevention, Shenzhen 518055, China;4. Institute of Environment and Health, Jianghan University, Wuhan 430056, China
Abstract:Within-house and within-room spatial temporal variability in PBDE contamination of indoor dust may influence substantially the reliability of human exposure assessments based on single point samples, but have hitherto been little studied. This paper reports concentrations of PBDEs 17, 28, 47, 49, 66, 85, 99, 100, 153, and 154 in indoor dust samples (n = 112) from two houses in Birmingham, UK. To evaluate within-house spatial variability, four separate rooms were sampled in house 1 and two separate rooms sampled in house 2. Up to four different 1 m2 areas in the same room were sampled to evaluate within-room spatial variability, and for all studied areas, samples were taken for eight consecutive months to evaluate temporal and seasonal variability. Concentrations of ΣPBDEs in individual samples from house 1 varied between 21 and 280 ng g 1; while the range of concentrations in house 2 was 20–1000 ng g 1. This indicates that where and when a sample is taken in a house can influence substantially the contamination detected. In one room, concentrations of PBDEs in an area located close to putative PBDE sources exceeded substantially those in an area 2 m away, with marked differences also observed between two areas in another room. Substantial within-room spatial differences in PBDE concentrations were not discernible in the other rooms studied. Concentrations of PBDEs in the majority of rooms within the same houses were not markedly different between rooms. Nevertheless, large differences were observed between PBDE concentrations detected in two rooms in the same house in both houses studied. In one instance, this is hypothesised to be attributable to the presence of a carpet in one room and bare wooden floor in another, but firm conclusions cannot be drawn. Within-room temporal (month-to-month) variability was substantial (relative standard deviations for ΣPBDEs = 15–200%). In some rooms, the introduction and removal of putative sources like a TV and a bed, appeared to exert a discernible influence on PBDE concentrations. PBDE concentrations in spring and summer were not markedly different from those observed in autumn and winter. Possible dilution of PBDE concentrations in dust at higher dust loadings (g dust per m2 floor surface) was investigated in a small number of rooms, but no firm evidence of such dilution was evident.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号