Low‐Capacity Well Pairs for Treating Contaminated Groundwater in Homogeneous and Heterogeneous Aquifers |
| |
Authors: | Paul F. Hudak |
| |
Affiliation: | Department of Geography and Environmental Science, University of North Texas |
| |
Abstract: | Groundwater remediation alternatives were simulated for homogeneous and heterogeneous aquifers with a numerical mass transport model. Low‐energy alternatives involved an injection–extraction well pair positioned along a downgradient linear transect. This transect was located 5 m from the contaminant plume and oriented perpendicular to the regional hydraulic gradient. Through numerous trials, for one homogeneous and three heterogeneous settings, the model identified an optimal spacing and minimum pumping rate for a well pair: (1) centered on the downgradient tip of the plume (best centered), and (2) anywhere along the downgradient transect (best overall). Results suggest that low‐energy well pairs are an effective means for containing and removing some contaminant plumes, and best‐performing configurations are generally not centered on the downgradient tip of the initial contaminant plume. ©2015 Wiley Periodicals, Inc. |
| |
Keywords: | |
|
|