首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A pre-denitrification activated sludge system (AS) without internal recycle was used in lab-scale studies of landfill leachate treatment. A bentonite supplement at a ratio of 1:4 (mineral : biomass) was used to ensure high sludge settling levels and to serve as a micro-organisms carrier. The system was operated within different parameters such as hydraulic retention time (HRT), ammonia loading rate (ALR) or external recycle ratio, which was adapted to treat varying leachate concentrations of COD and ammonia, ranging from 1020 to 2680 mgO(2)l(-1) and 400-890 mgNH(4)-Nl(-1) respectively. The nitrification was complete and ammonia oxidation reached 99%; this was obtained while the ALR did not exceed 0.09 g NH(4)(+)-Ng(-1)MLVSS d(-1) and HRT was not lower than 1 day (in the aeration reactor). The performance of denitrification was successfully improved by controlling the external recycle rate, when the BOD(5)/N ratio in the raw leachate was 4.1. Consequently, N-removal of up to 80% was achieved. A 10-fold decrease in the denitrification rate was obtained at a BOD(5)/N ratio of 0.5. The efficiency of COD removal varied significantly from 36% to 84%. The positive effect of bentonite addition was determined and is discussed based on preliminary studies. The experiments were carried out in fill-and-draw activated sludge with bentonite; the biomass ratio was 1:2. The activated sludge with bentonite was fed with a synthetic high ammonia and organic-free medium.  相似文献   

2.
Summary This study is carried out to propose an appropriate treatment technology for wastewater discharged from a flavor production factory. Industrial wastewater discharged from this factory ranges between 50–70 m3/d with an average value of 60 m3/d. The major source of pollution in this factory is due to cleaning of the vessels therefore the treatment has been carried out on the end-of pipe wastewater. The wastewater is characterized by high values of COD, BOD, TSS and Oil and grease 4646, 2298, 1790 and 626 mg/l respectively. Primary sedimentation of the wastewater for four hours reduced the COD, BOD, TSS and Oil and grease by 43, 47, 80 and 74%, respectively. For the treatment of the produced wastewater, the biological treatment process such as activated sludge, rotating biological contactor (RBC), up-flow anaerobic sludge bed reactor (UASB) have been selected. The results from each treatment process proved to be efficient for the treatment of such wastewater. The treated wastewater characteristics are in compliance with the Egyptian law which regulates the discharge of industrial wastewater to the sewerage system. The RBC was selected and installed by the factory as it has the advantage of low operating and maintenance costs. The factory RBC performance was monitored; characteristics of the treated effluent in terms of oil and grease, COD, BOD and TSS were 27, 362, 139 and 95 mg/l, respectively.  相似文献   

3.
Due to the toxic nature of chlorophenol compounds present in some chemical industry effluents, biological treatment of such wastewaters is usually realized with low treatment efficiencies. Para-chlorophenol (4-chlorophenol, 4-CP) containing synthetic wastewater was treated in an activated sludge unit at different hydraulic residence times (HRT) varying between 5 and 30 h while the feed COD (2500 mg l(-1)), 4-CP (500 mg l(-1)) and sludge age (SRT, 10 days) were constant. Effects of HRT variations on COD, 4-CP, toxicity removals and on settling characteristics of the sludge were investigated. Percent COD removals increased and the effluent COD concentrations decreased when HRT increased from 5 to 15 h and remained almost constant for larger HRT levels. Nearly, 91% COD and 99% 4-CP removals were obtained at HRT levels above 15 h. Because of the highly concentrated microbial population at HRT levels of above 15 h, low effluent (reactor) 4-CP concentrations and almost complete toxicity removals were obtained. High biomass concentrations obtained at HRT levels above 15 h were due to low 4-CP contents in the aeration tank yielding negligible inhibition effects and low maintenance requirements. The sludge volume index (SVI) decreased with increasing HRT up to 15 h due to high biomass concentrations at high HRT levels resulting in well settling sludge with low SVI values. Hydraulic residence times above 15 h resulted in more than 90% COD and complete 4-CP and toxicity removals along with well settling sludge.  相似文献   

4.
A sequencing batch reactor biofilm (MSBR) system was modified from the conventional sequencing batch reactor (SBR) system by installing 2.7 m2 surface area of plastic media on the bottom of the reactor to increase the system efficiency and bio-sludge quality by increasing the bio-sludge in the system. The COD, BOD5, total kjeldahl nitrogen (TKN) and oil & grease removal efficiencies of the MSBR system, under a high organic loading of 1340 g BOD5/m3 d, were 89.3+/-0.1, 83.0+/-0.2, 59.4+/-0.8, and 82.4+/-0.4%, respectively, while they were only 87.0+/-0.2, 79.9+/-0.3, 48.7+/-1.7 and 79.3+/-10%, respectively, in the conventional SBR system. The amount of excess bio-sludge in the MSBR system was about 3 times lower than that in the conventional SBR system. The sludge volume index (SVI) of the MSBR system was lower than 100 ml/g under an organic loading of up to 1340 g BOD5/m3 d. However, the MSBR under an organic loading of 680 g BOD5/m3 d gave the highest COD, BOD5, TKN and oil & grease removal efficiencies of 97.9+/-0.0, 97.9+/-0.1, 79.3+/-1.0 and 94.8+/-0.5%, respectively, without any excess bio-sludge waste. The SVI of suspended bio-sludge in the MSBR system was only 44+/-3.4 ml/g under an organic loading of 680 g BOD5/m3 d.  相似文献   

5.
The operational parameter MRT%FE, representing the mean residence time of different ages fractions of effluent within a completely mixed reactor, was evaluated and integrated with first order kinetics. The parameter was used to model Escherichia coli concentrations in a municipal wastewater reservoir managed under different operating conditions (continuous and discontinuous). The study was conducted during 2004-2005 in a reservoir receiving effluents from the activated sludge treatment plant of Caltagirone (Eastern Sicily - Italy). The analytical approach is applied to the hydraulic state variables of the system (daily stored volumes, inlet and outlet flows), and the physical-chemical (pH, temperature, EC, TSS, BOD(5), COD) and bacteriological wastewater parameters (E. coli, FC, FS). In order to evaluate the reliability of the proposed approach, predicted E. coli concentrations within the reservoir were compared with measured ones by the correlation coefficient, F-test and Sperman's index. The study included the evaluation of die-off coefficient K(T) (d(-1)), light extinction coefficient K (m(-1)) and their relationships with climatic factors. Results of the study confirm that E. coli removal is related to the fractions of fresh effluent remaining each day within the reservoir with MRT%FE of about 5-8d, significantly lower than the nominal detention time (about 27d). The E. coli die-off coefficient (K(T)) was higher during system discontinuous operations and correlated with incident solar radiation and water temperature.  相似文献   

6.
The production of highly polluting palm oil mill effluent (POME) has resulted in serious environmental hazards. While anaerobic digestion is widely accepted as an effective method for the treatment of POME, anaerobic treatment of POME alone has difficulty meeting discharge limits due to the high organic strength of POME. Hence, subsequent post-treatment following aerobic treatment is vital to meet the discharge limits. The objective of the present study is to investigate the aerobic treatment of anaerobically digested POME by using a sequencing batch reactor (SBR). The SBR performance was assessed by measuring Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) removal as well as Sludge Volume Index (SVI). The operating pH and dissolved oxygen concentrations were found to be 8.25–9.14 and 1.5–6.4 mg/L, respectively, throughout the experiment. The experimental results demonstrate that MLVSS, OLR and sludge loading rate (SLR) play a significant role in the organic removal efficiency of SBR systems and therefore, further investigation on these parameters was conducted to attain optimum SBR performance. Maximum COD (95–96%), BOD (97–98%) and TSS (98–99%) removal efficiencies were achieved at optimum OLR, SLR and MLVSS concentration ranges of 1.8–4.2 kg COD/m3 day, 2.5–4.6 kg TSS/m3 day and 22,000–25,000 mg/L, respectively. The effluent quality remained stable and complied with the discharge limit. At the same time, the sludge showed good settling properties with average SVI of 65. It is envisaged that the SBR process could complement the anaerobic treatment to produce final treated effluent which meets the discharge limit.  相似文献   

7.
A conventional activated sludge treatment facility was the subject of this study. The assessment was directed at determining the characteristics of the raw wastewater, the quality of the treated effluent and the efficiency of the various treatment units. Furthermore, the water quality along the effluent irrigation canal was monitored. The assessment of the quality of the treated effluent for irrigation is based on the guidelines established by the World Health Organization and the Egyptian decree 9/89 for the use of wastewater in agriculture. The results of the study indicated that the concentration of the raw wastewater was considered moderate. The mean values of the COD (Chemical Oxygen Demand), BOD (Biological Oxygen Demand) and total suspended solids (TSS) were around 250, 102 and 142 mg l–1, respectively. This was attributed to the high quantities of wastewater from industrial sources. The overall efficiency of the treatment facility was good. The mean residual COD, BOD and TSS were 25, 8 and 21 mg l–1 and the corresponding percentage removal values were 90, 92 and 85%, respectively. The maximum percentage removal of oil and grease was 84% with a mean residual concentration of 24 mg l–1. The total viable count (22°C and 37°C), faecal coliform and aecal streptococci were reduced by 99.9% compared to only 99.5% for Salmonella. Bacteriological examination of the dried sludge indicated a reduction of nine logs of faecal coliform and faecal streptococci, as compared to thickened sludge. Analysis of the Ni, Cu, Pb and Cr in the dried sludge indicated that their concentrations are within the permissible limits. Zinc exceeded the consent standards by 50%. The results of the analyses of samples collected at the beginning of the irrigation canal indicated insignificant changes from the characteristics of the final effluent. Samples collected at a distance of 2km along the irrigation canal showed mean reductions in the COD and BOD of 28.6 and 47%, respectively, which could be attributed to sedimentation and/or a self-purification effect. An increase in the total nitrogen, total phosphorus and total viable count was also recorded, which could be due to seepage from the agricultural land. From the data available it is evident that the treated wastewater could be used for restricted irrigation. The design and implementation of a monitoring programme is recommended.  相似文献   

8.
对常规活性污泥法和一体化氧化沟工艺在中原油田基地污水厂的应用效果进行了对比分析。月度抽查对比监测发现,两种生物处理法对有机物均有较好的去除效果。一体化氧化沟工艺是一种新型的生活污水处理技术,它对SS、NH3-N的去除效果优于常规法。连续三天的日均值监测结果表明,新工艺对各种污染物的去除效果达到91%以上。这种工艺集通氧、沉淀、废渣分离和回收为一体,占地面积小,操作简单,在中原油田污水站取得了较好的应用效果。  相似文献   

9.
厌氧水解—高负荷生物滤池处理城镇污水的试验研究   总被引:3,自引:0,他引:3  
厌氧水解-高负荷生物滤池是一种利用附着在塑料模块填料上的微生物系统对城镇污水中的污染物质进行降解处理的绿色环保技术。厌氧水解池和高负荷生物滤池采用的塑料模块填料具有高空隙率、高附着面积、高布水性能和抗堵塞的优异性能,并无须回流。当厌氧水解池水力停留时间为4小时,生物滤池水力负荷为30米^3/米^2。日,该系统处理城镇污水的CODCr去除率达80-86%,BOD5去除率达85%-95%。SS去除率达85-95%,处理后出水上述各项指标均可满足国家二级生物处理排放标准的要求。与广泛运用的活性法处理系统相比,该技术可节约基建投资20%以上,节约能耗50%以上,同时还具有流程简单、管理方便、耐冲击负荷、剩余污泥少等特点。  相似文献   

10.
A study was conducted to examine N and P removal by a laboratory-scale extended aeration treatment system employing oxidation-reduction potential (ORP) controlled aeration. The system was provided with a 90-L aeration tank. When ORP controlled aeration was applied, the aeration tank was divided into three zones, namely the ORP zone (45 L), the anaerobic zone (27 L) and the aerobic zone (18 L). An external anoxic selector of 3.8 L in volume was also added. An ORP set point of 70 mV was used for the ORP zone. The extended aeration treatment system operating without the ORP controlled aeration was used as the control.COD removal (97%) was not affected, but both N and P removal were enhanced significantly in the ORP reactor. Total N removal efficiency was increased from 49.1% (control) to 83.5%. Almost all P was captured (99%), leaving an average of 0.09 mg L−1 P in the effluent. The ORP reactor yielded a sludge P content of 3.1%, compared to only 1.8% for the control. This indicated luxury P uptake in ORP reactor. Very significant P release and denitrification were found in the anoxic selector. Fairly good simultaneous nitrification and denitrification had occurred in the ORP zone. However, P release was very limited in the anoxic zone. However, anoxic P uptake and nitrification were found in this zone.Low F/M bulking was observed in both the control and ORP operation before the installation of a selector. Bacterial Type 0041 was identified as the predominant bulking organism. For the Control, an aerobic selector cured the bulking problem in one sludge age while an anoxic selector fixed up the problem during the ORP operation.  相似文献   

11.
针对污泥处理处置过程中的环境问题和经济问题,将传统的活性污泥工艺(CAS)与好氧—沉淀—厌氧工艺(OSA)对比,研究了两种工艺对污泥减量化的影响,分析了两种工艺对废水中COD浓度、COD去除效率、氨氮浓度及SVI值的影响,并指出OSA工艺运行稳定,抗冲击能力强,其引起的解偶联代谢能促进污泥产率下降。  相似文献   

12.
In this study treatment of palm oil mill effluent (POME) was investigated using aerobic oxidation based on an activated sludge process. The effects of sludge volume index, scum index and mixed liquor suspended solids during the acclimatizing phase and biomass build-up phase were investigated in order to ascertain the reactor stability. The efficiency of the activated sludge process was evaluated by treating anaerobically digested and diluted raw POME obtained from Golden Hope Plantations, Malaysia. The treatment of POME was carried out at a fixed biomass concentration of 3900+/-200mg/L, whereas the corresponding sludge volume index was found to be around 105+/-5mL/g. The initial studies on the efficiency of the activated sludge reactor were carried out using diluted raw POME for varying the hydraulic retention time, viz: 18, 24, 30 and 36h and influent COD concentration, viz: 1000, 2000, 3000, 4000 and 5000mg/L, respectively. The results showed that at the end of 36h of hydraulic retention time for the above said influent COD, the COD removal efficiencies were found to be 83%, 72%, 64%, 54% and 42% whereas at 24h hydraulic retention time they were 57%, 45%, 38%, 30% and 27%, respectively. The effectiveness of aerobic oxidation was also compared between anaerobically digested and diluted raw POME having corresponding CODs of 3908 and 3925mg/L, for varying hydraulic retention time, viz: 18, 24, 30, 36, 42, 48, 54 and 60h. The dissolved oxygen concentration and pH in the activated sludge reactor were found to be 1.8-2.2mg/L and 7-8.5, respectively. The scum index was found to rise from 0.5% to 1.9% during the acclimatizing phase and biomass build-up phase.  相似文献   

13.
In this study, two pilot-scale aerobic landfill reactors with (A1) and without (A2) leachate recirculation are used to obtain detailed information on the quantity and quality of leachate in aerobic landfills. The observed parameters of leachate quality are pH, chloride (Cl), chemical oxygen demand (COD), biological oxygen demand (BOD), total Kjeldahl nitrogen (TKN), ammonia nitrogen (NH3-N), and nitrate (NO3-N). pH values of the leachate increased to 7 after 50 days in reactor A1 and after 70 days in reactor A2. Cl concentrations increased rapidly to 6100 (A1) and 6900 (A2) mg/L after 80 days, from initial values of 3000 and 2800 mg/L, respectively. COD and BOD values decreased rapidly in the A1 landfill reactor, indicating the rapid oxidation of organic matter. The BOD/COD ratio indicates that leachate recirculation slightly increases the degradation of solid waste in aerobic landfills. NH3-N concentrations decreased as a result of the nitrification process. Denitrification occurred in parts of the reactors as a result of intermittent aeration; this process causes a decrease in NO3 concentrations. There is a marked difference between the A1 and A2 reactors in terms of leachate quantity. Recirculated leachate made up 53.3% of the leachate generated from the A1 reactor during the experiment, while leachate quantity decreased by 47.3% with recirculation when compared with the aerobic dry landfill reactor.  相似文献   

14.
A pilot plant was set up to treat dye waste water. The flow of the plant begins with a chemical pretreatment step following by an immobilized decolorizing bacteria reactor and an ordinary activated sludge reactor at the end. Results from the seven months' operation show that the decolorization effect of the immobilized cell reactor worked satisfactorily. The effluent colour always remained below 100 with the influent colour as high as 4000 or more. The COD of the effluent could also meet the discharge standard, around 60 mg L−1. The immobilized cell reactor has an ability to reduce the BOD/COD ratio of the waste, suggesting that it can degrade the recalcitrant pollutants easily. The results show that it is a high-efficiency and low-cost process suitable to be developed into full-scale application.  相似文献   

15.
This paper investigates the removal of coliforms in full-scale activated sludge plants (ASP) operating in northern regions of India. Log2.2 and log2.4 removal were observed for total coliforms (TC) and fecal coliforms (FC), respectively. However, the effluent still contained a significant number of TC and FC which was greater than the permissible limit for unrestricted irrigation as prescribed by WHO. The observations also suggest that extended aeration (EA) process operating under high mixed liquor suspended solids (MLSS) and sludge retention time (SRT) is more efficient in the removal of coliforms. Further attempts have been made to establish the relationship between two key wastewater parameters, i.e. biochemical oxygen demand (BOD) and suspended solids (SS) with respect to fecal and TC. The relationships were observed to be linear with a good coefficient of correlation. The interrelationship of BOD and SS with coliforms manifest that improvement of the microbiological quality of wastewater could be linked with the removal of SS. Therefore, SS can serve as a regulatory tool in lieu of an explicit coliforms standard.  相似文献   

16.
微生物菌剂在酿酒废水处理中的应用研究   总被引:6,自引:1,他引:5  
采用厌氧-好氧工艺,结合微生物菌剂对酿酒废水进行了处理研究。进水CODCr浓度可达到8,456.3-22,442.0mg/L,BOD55,040.0-9.557.1mg/L,pH3-4,可不调pH,采用微生物菌剂接种可启动厌氧反应器,COD有机负荷最高达到10.2gCOD/Ld,COD去除率稳定在91-95%,BOD去除率90-94%,出水pH6.6-7.1,出水CODCr在2,000mg/L以下,BOD5800mg/L以下。厌氧污泥可全部颗粒化。好氧处理系统中接种微生物菌剂,曝气10-12小时,可保证出水中CODCr在230mg/L以下,甚至直接达到国家一级排放标准。微生物菌剂的应用是取得该处理效果的关键。  相似文献   

17.
水解酸化对感光胶片废水生化反应动力学系数的影响   总被引:1,自引:1,他引:0  
采用水解酸化工艺可有效地提高工业废水中难生物降解有机物的可生化性,为后续好氧生化处理创造有利条件。本试验在对感光胶片废水采用水解酸化-活性污泥法工艺和常规活性污泥法进行平行对照试验的基础上,从生化反应动力学系数的角度研究水解酸化过程对好氧生化反应的影响。研究结果表明:经水解酸化处理后,在该废水的BOD5/CODCr比值从046-048提高至054-056的同时,后续活性污泥系统的动力学半速度数Ks从常规活性污泥法的459毫克/升下降至103毫克/升,最大比降解速度K从30/日上升至50/日,可用于表征该工业废水可生化性和后续好氧化物处理效果改善和提高的程度。  相似文献   

18.
To gain more insight into the interactions between anaerobic bacteria and reactor performances (chemical oxygen demand-COD, 2,4 dichlorophenol-2,4 DCP removals, volatile fatty acid-VFA, and methane gas productions) and how they depended on operational conditions the microbial variations in the anaerobic granular sludge from an upflow anaerobic sludge blanket (UASB) reactor treating 2,4 DCP was studied. The study was composed of two parts. In the first part, the numbers of methanogens and acedogens in the anaerobic granular sludge were counted at different COD removal efficiencies. The relationships between the numbers of methanogens, the methane gas production and VFA production were investigated. The COD removal efficiencies increased to 74% from 30% while the number of total acedogens decreased to 10 from 30 cfu ml(-1). The number of total methanogens and acedogens varied between 11 x 10(3) and 10 x 10(9)MPN g(-1) and 10 and 30 cfu ml(-1) as the 2,4 DCP removal efficiencies were obtained between 60% and 99%, respectively. It was seen that, as the number of total acedogens decreased, the COD removal efficiencies increased. However, the number of total methanogens increased as the COD removal efficiencies increased. Correlations between the bacterial number and with the removal efficiencies obtained in different operational conditions were investigated. From the results presented in this paper a high correlation between the number of bacteria, COD removals, methane gas percentage, 2,4 DCP removals and VFA was observed. In the second part, methanogen bacteria in the anaerobic granular sludge were identified. Microbial observations and biochemical tests were applied to identify the anaerobic microorganisms from the anaerobic granular sludge. In the reactor treating 2,4 DCP, Methanobacterium bryantii, Methanobacterium formicicum, Methanobrevibacter smithii, Methanococcus voltae, Methanosarcina mazei, Methanosarcina acetivorans, Methanogenium bourgense and Methanospirillum hungatei were identified.  相似文献   

19.
In order to improve the process performance regarding the removal of organics, nitrogen, and an odor-causing compound (sulfide) contained in domestic wastewater, an entrapped-mixed-microbial cell (EMMC) with and without humic substances for both fixed and moving carrier reactors and conventional suspended growth culture (i.e. conventional activated sludge process) were investigated simultaneously. Both synthetic (simulated to the organics concentration of general domestic sewage) and actual domestic wastewater were investigated under operational conditions of 12 h of hydraulic retention time (HRT) with 1 h of aeration and 1 h of non-aeration, and 6 h of HRT with continuous aeration, at a room temperature of 25 +/- 2 degrees C. It was found that entrapping humic substances in the EMMC carriers had no impact on the removal of organics, nitrogen, and the odor-producing compound. Additionally, the performance of the EMMC moving carrier system for the removal of these pollutants is similar to that of the EMMC fixed carrier system. In general, the EMMC associated systems which provide high solids retention time achieve a better removal of chemical oxygen demand (COD), nitrogen, and the odor-producing substance than the suspended growth system for both HRTs of 6 h (continuous aeration) and 12 h (1 h of aeration and 1 h of non-aeration). Both the fixed and moving carrier EMMC processes, therefore, have the potential for improvement or replacement of the existing conventional activated sludge process with regard to improving the effluent qualities (such as COD, nitrogen and odor-producing compound) for reuse/disposal.  相似文献   

20.
The effectiveness of sewage purification by aquatic plants, such as water hyacinth (Eichhornia crassipes) and water lettuce (Pistia stratiotes), was tested on laboratory and pilot scales. Cascade and semi-continuous pilot experiments verified that the plants are capable of decreasing all tested indicators of water quality to levels that permit the use of the purified water for irrigation of tree crops. This applies to biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), and turbidity. The laboratory-scale tests confirm the capacity of the plants to reach and hold reasonably low levels of BOD (5-7 mg L(-1)) and COD (40-50 mg L(-1)) and very low levels of TSS (3-5 mg L(-1)) and turbidity (1-2 NTU). In the experimental pilot setup, with circulation, COD decreased from 460 to 100 mg L(-1) after 2.5-4 days of treatment, while 6-7 days were required to this end without circulation. This doubled the active pond area and provided a two-level hydraulic loading (8 and 12 L min(-1)) with circulation that proved to be effective during the summer as well as the winter season. The outflow concentrations were 50-85 mg L(-1) of COD and 4-6 mg L(-1) of BOD. The results show that the use of this free water surface flow system (FWS) and its low maintenance system for treatment of urban and agricultural sewage is a viable option.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号