1.
A new airlift intermittent circulation integrated bioreactor was developed for simultaneous nitrogen and phosphorus removal of wastewater, in which, circulation of mixed liquid between mixing zone and aeration zone was realized by aeration power, alternately anaerobic/anoxic bio-environment in mixing zone was realized by intermittent circulation and simultaneous nitrogen and phosphorus removal was obtained through strengthened denitrifying phosphorus removal process. Removal performance of the reactor was investigated and pollutant removal and transfer mechanism in one operation circle was analyzed. The experiment results indicated that under the influent condition of chemical oxygen demand (COD) concentration of 642.1 mg/L, total nitrogen (TN) of 87.4 mg/L and PO43?-P of 12.1 mg/L, average removal efficiencies of COD, TN and PO43?-P reached 96.4%, 83.2% and 90.5%, respectively, with the hydraulic residence time of 22 hr and operation circle time of 185 min. Track studies indicated that the separation of aeration and mixing zones and intermittent circulation of mixed liquid between the two zones provided distinct biological environments spatially and temporally, which ensured the occurrence of multifunctional microbial reactions.  相似文献   

2.
吴鹏  程朝阳  沈耀良  赵诗惠  吕亮 《环境科学》2017,38(9):3781-3786
基于厌氧折流板反应器(ABR)微生物相分离及膜生物反应器(MBR)高效截留的特性,通过加设硝化液回流与污泥回流实现了ABR-MBR一体化反应器的循环联动,对连续流条件下调控进水COD浓度及COD/TN比条件下的反硝化除磷影响机制展开了研究.结果表明在5个不同进水C/N比下,ABR-MBR组合工艺最终出水溶解性PO_3-4-P平均浓度分别为0.22、0.34、0.39、0.42和2.45 mg·L~(-1),低C/N比可获得更好的除磷效果,而C/N为4.8~6.0时,工艺对COD、TN和溶解性PO_3-4-P去除率分别在87%、76%和93%以上.此外,在C/N为3.6~6.0时,ABR缺氧吸磷量与工艺对TN去除量呈良好的线性关系,提高进水C/N比有助于系统对TN的去除.最终获得进水C/N比为6时最有利于氮和磷的同步去除.  相似文献   

3.
间歇曝气连续流反应器同步硝化反硝化除磷   总被引:4,自引:4,他引:0  
采用连续流反应器处理生活污水,保持厌氧段格室为3格,将缺氧段格室从2格减少至0格,好氧段格室由5格逐渐增加至7格,Run1时对好氧段格室采用连续曝气,Run2~Run4时采用间歇曝气.曝/停比分别为:40 min/20 min、40 min/30min、40 min/40 min,硝化液回流比从150%逐渐减少至0%. Run4时,平均进水COD、NH+4-N、TN、PO_4~(3-)-P浓度分别为259. 34、60. 26、64. 42、6. 10 mg·L-1,出水COD、NH+4-N、TN、PO_4~(3-)-P分别为26. 40、1. 03、5. 84、0. 30 mg·L-1.反应器对氮素的去除量从Run1时的192. 30 mg·h-1逐渐增加至Run4时的244. 00 mg·h-1,相应地去除率从65. 40%逐渐增大至95. 30%;从Run1~Run4,反硝化聚磷菌和聚磷菌的活性分别从36. 05%和38. 20%增大至140. 50%和133. 40%;通过间歇曝气在连续流反应器中实现了同步硝化反硝化除磷脱氮,为污水处理厂提标改造提供参考.  相似文献   

4.
为了解同步短程硝化内源反硝化除磷(SPNDPR)系统的脱氮除磷特性,以低C/N城市污水为处理对象,采用延时厌氧(180 min)/好氧运行的SBR反应器,通过联合调控曝气量和好氧时间,考察了该系统启动与优化运行特性.结果表明,当系统好氧段曝气量为0. 8 L·min~(-1),好氧时间为150 min时,出水PO_4~(3-)-P浓度约为1. 5 mg·L~(-1)左右,出水NH_4~+-N和NO_3~--N浓度由10. 28 mg·L~(-1)和8. 14 mg·L~(-1)逐渐降低至0 mg·L~(-1)和2. 27 mg·L~(-1),出水NO_2~--N浓度逐渐升高至1. 81 mg·L~(-1);当曝气量提高至1. 0 L·min~(-1)且好氧时间缩短至120min后,系统除磷、短程硝化性能逐渐增强,但总氮(TN)去除性能先降低后逐渐升高,最终出水PO_4~(3-)-P、NH_4~+-N分别稳定低于0. 5 mg·L~(-1)和1. 0 mg·L~(-1),好氧段亚硝积累率和SND率分别达98. 65%和44. 20%,TN去除率达79. 78%. SPNDPR系统内好氧段好氧吸磷、反硝化除磷、短程硝化、内源反硝化同时进行保证了低C/N污水的同步脱氮除磷.  相似文献   

5.
基于优质碳源提供的CAMBR复合工艺短程硝化-反硝化除磷研究   总被引:10,自引:10,他引:0  
程继辉  吴鹏  程朝阳  沈耀良 《环境科学》2015,36(12):4539-4545
挥发性脂肪酸(VFA)是反硝化除磷过程可以利用的优质碳源,为此本研究结合厌氧折流板反应器(ABR)微生物相分离和膜生物反应器(MBR)出水水质优良的特性,构建了CAMBR复合工艺,并通过优化ABR水力停留时间(HRT)等运行条件以提供优质碳源,实现高效反硝化除磷.研究表明,当ABR的HRT为4.8 h时,可获得充足的VFA作为优质碳源,并实现消耗VFA的量为56.1 mg·L~(-1)的同时获得10.43 mg·L~(-1)的释磷,即释放1 mg磷需要的VFA量为5.38 mg,同时实现12.35 mg·L~(-1)的吸磷,而MBR池的吸磷为1.33 mg·L~(-1).短程硝化除磷过程中,缺氧消耗1 mg PO_4~(3-)-P需要0.62 mg的NO-x-N,吸收1 mg PO_4~(3-)-P所需NO_2~--N的量为1.67~2.04 mg.系统出水水质稳定,COD、TN和溶解性PO_4~(3-)-P的平均去除率分别为91%、84%和93%,出水平均浓度分别为30、7.15和0.55 mg·L~(-1),表明CAMBR复合工艺生在处理生活污水过程中可获得稳定高效的反硝化除磷效果.  相似文献   

6.
为了解厌氧/好氧/缺氧(A/O/A)运行的序批式反应器(SBR)中,强化生物除磷(EBPR)与同步短程硝化反硝化(SPND)耦合,并后置短程反硝化的脱氮除磷特性,以低C/N(≤4)城市污水为处理对象,通过优化曝气量和缺氧时间,实现了低C/N城市污水的深度脱氮除磷.结果表明,当好氧段曝气量由1.0 L·min-1降至0.6 L·min-1,缺氧时间为180 min时,出水PO3-4-P浓度由0.06 mg·L~(-1)降至0,出水NH+4-N、NO-2-N和NO-3-N浓度分别由0.18、18.79和0.08 mg·L~(-1)逐渐降低至0、16.46和0.05 mg·L~(-1),TN去除率由72.69%提高至77.97%;随着曝气量的降低,SPND现象愈加明显,SND率由19.18%提高至31.20%;此后,当缺氧段时间由180 min逐渐延长至420 min,出水PO3-4-P、NH+4-N和NO-3-N浓度分别维持在0、0和0.03 mg·L~(-1)左右,出水NO-2-N低至3.06 mg·L~(-1),SND率达32.21%,TN去除性能逐渐提高,TN去除率高达99.42%,实现了系统的深度脱氮除磷.  相似文献   

7.
生物滞留对城市地表径流磷的去除途径   总被引:3,自引:1,他引:2  
李立青  刘雨情  杨佳敏  王娟 《环境科学》2018,39(7):3150-3157
根据武汉城市地表径流水文变化以及磷污染特征,通过1 a模拟运行监测,研究了生物滞留种植植物(狼尾草)、设置饱和带对城市地表径流溶解性磷(PO3-4-P)去除的影响及去除途径.结果表明,生物滞留采用75%河砂与25%当地黄棕壤混合基质,对地表径流PO3-4-P的平均去除率可达到90%以上.生物滞留种植狼尾草可显著降低出水PO3-4-P浓度.生物滞留设置饱和带可进一步提高对PO3-4-P的去除,不影响出水TP浓度.生物滞留通过基质吸附去除地表径流中的磷,表现为0~22.5 cm基质剖面中植物有效磷的增加,约占试验期间进水磷负荷的50%.从生物滞留系统磷输入(进水)与输出(出水与植物地上部分)角度分析,种植狼尾草一个生长周期地上部分吸收的磷可占进水磷负荷57.1%~76.1%,定期收割植物地上部分可作为城市地表径流磷可持续管理的主要途径.  相似文献   

8.
为了解同步硝化内源反硝化系统(SNEDPR)脱氮除磷性能,采用延时厌氧(180 min)/低氧(溶解氧0. 5~2. 0 mg·L~(-1))运行的SBR反应器,以人工配置的模拟废水为处理对象,先采用恒定进水C/N(为10),以实现SNEDPR的启动和聚磷菌(PAOs)的富集培养,再调控进水C/N值(分别为10、7. 5、5和2. 5),考察不同C/N对系统的脱氮除磷性能的影响.结果表明,当进水C/N为10,可实现SNEDPR的启动与深度脱氮除磷,出水PO3-4-P和总氮(TN)浓度分别平均为0. 1 mg·L~(-1)和8. 1mg·L~(-1),PO3-4-P去除率、TN去除率和SNED率平均值分别为99. 79%、89. 38%和58. 0%.当进水C/N由5提高至10时,系统维持良好的脱氮除磷性能,释磷量(PRA)和SNED率分别由16. 0 mg·L~(-1)和48. 0%提高至24. 4 mg·L~(-1)和69. 2%;当C/N为10时,TN和PO3-4-P去除率最高达94. 5%和100%;当C/N为2. 5时,系统失去脱氮、除磷性能,PRA和SNED率仅为1. 36 mg·L~(-1)和10%.在系统稳定运行阶段(C/N为10、7. 5和5),SNED率达85. 9%,出水NH_4~+-N、NO-x-N和PO3-4-P浓度平均为0、8. 1和0. 1 mg·L~(-1).  相似文献   

9.
间歇曝气对垂直潜流人工湿地脱氮效果的影响   总被引:4,自引:2,他引:2  
采用单级垂直潜流湿地处理城镇污水厂沉砂池出水,通过提高湿地出水水位控制淹没水深作为缺氧区;并在湿地反应柱下部安装穿孔曝气管,从而在湿地上部创造好氧环境.通过优化间歇曝气的曝气时间与间歇时间比例(间歇曝气比例)以及间歇曝气周期两个参数来提高湿地脱氮效率.结果表明,随着间歇曝气比例增大,湿地对COD和NH~+_4-N的去除率逐渐升高,而TN去除率有先升高后下降的趋势,当曝气比例为3∶1时,缺氧段污水碳氮比(C/N)值达到4.8,TN去除率达到最高为62.1%,较连续曝气提高了12.7%,出水质量浓度为15.8 mg·L~(-1).随着间歇曝气周期的延长,出水DO质量浓度逐渐降低,COD和NH~+_4-N去除率也逐渐降低,TN去除率在周期为6 h时达到最大为65.5%,当曝气周期超过湿地缺氧段水力停留时间时,TN去除率迅速下降.  相似文献   

10.
对比考察了不同曝气强度下序批式活性污泥反应器(SBR)和序批式移动床生物膜反应器(SBMBBR)的脱氮除磷效果,并分析了反应器单个周期内有机物、氮和磷的转化过程.实验结果表明,SBMBBR和SBR脱氮主要是基于好氧段发生的同步硝化反硝化(SND)及进水、搅拌阶段发生的缺氧反硝化途径实现的,而除磷是基于常规生物除磷和反硝化除磷过程而完成.曝气强度会影响SBR和SBMBBR好氧阶段SND发生的程度,最佳曝气强度下两者通过SND作用去除的TN量分别达到去除总量的47.7%和79.0%.在采用先行厌氧的运行方式,保持系统内高浓度微生物,使反应器在进水C/N比只有2.2~3.5的条件下均取得了良好的脱氮除磷效果.两者相比,SBMBBR和SBR在COD和NH4-N去+除方面没有差异,而SBMBBR的反硝化、除磷效果更优,TN、TP去除率分别达到95.4%和93.5%,较SBR分别高出10.9%和4.1%.  相似文献   

11.
除磷颗粒诱导的同步短程硝化反硝化除磷颗粒污泥工艺   总被引:6,自引:6,他引:0  
李冬  刘博  王文琪  张杰 《环境科学》2020,41(2):867-875
以低C/N比生活污水为研究对象,接种成熟除磷颗粒污泥,通过联合调控好氧时间及曝气强度成功将其诱导成具有同步短程硝化反硝化除磷功能的颗粒污泥,并分析了此过程中系统脱氮除磷特性变化.结果表明,好氧段曝气强度为5L·(h·L)~(-1),在较短曝气时间下(140 min)可实现AOB的富集,但同步硝化反硝化能力难以提高;降低曝气强度为3. 5L·(h·L)~(-1),延长曝气时间(200 min),好氧段氮损增加.根据pH及DO曲线进一步优化曝气时长抑制NO_2~-向NO_3~-转化,优化后系统出水TP 0. 5 mg·L~(-1)和TN 15 mg·L~(-1),可实现氮磷的同步去除.在系统功能由单纯的除磷向同步脱氮除磷转化的过程中,释磷量下降,PAOs在内碳源储存过程中的贡献比例有所下降,但仍占主体地位(60%).批次实验表明,颗粒中可利用NO_2~-为电子受体的DPAOs占绝大部分达52. 43%,其富集减轻了系统的碳源压力,从而改善脱氮除磷效果.  相似文献   

12.
以低C/N城市污水为处理对象,采用延时厌氧(180min)/好氧运行的SBR反应器,通过调控曝气量[单位体积的反应器在单位时间内通过的气体的体积,单位为L·(min·L)~(-1).由0. 125 L·(min·L)~(-1)逐渐降低至0. 025 L·(min·L)~(-1)]和好氧时间(由3 h逐渐延长至6 h),考察了SPNDPR系统的深度脱氮除磷性能.结果表明,当曝气量为0. 025 L·(min·L)~(-1)、好氧时间为6 h时,SPNDPR系统出水NH_4~+-N、NO_2~--N、NO_3~--N和PO_4~(3-)-P浓度分别为0、8. 62、0. 06和0. 03 mg·L~(-1);出水TN浓度约为9. 22 mg·L~(-1),TN去除率高达87. 08%.当曝气量分别由0. 125 L·(min·L)~(-1)降至0. 100 L·(min·L)~(-1)和由0. 100L·(min·L)~(-1)降至0. 075 L·(min·L)~(-1)时,系统硝化速率均能恢复并稳定维持在0. 16 mg·(L·min)~(-1)左右.但曝气量继续降至0. 050 L·(min·L)~(-1)和0. 025 L·(min·L)~(-1)后,硝化速率分别降至0. 09 mg·(L·min)~(-1)和0. 06 mg·(L·min)~(-1)左右.随着曝气量的降低[由0. 125 L·(min·L)~(-1)依次降至0. 100、0. 075、0. 050、0. 025 L·(min·L)~(-1)]和好氧时间的延长(由3 h延长至6h),SPND脱氮性能逐渐增强,SND率由19. 57%升高至72. 11%,TN去除率逐渐升高(由62. 82%升高至87. 08%).降低曝气量和延长好氧时间后的SPNDPR系统,强化了厌氧段内碳源贮存与好氧段好氧吸磷、反硝化除磷、短程硝化、内源反硝化等过程的进行,实现了低C/N城市污水的深度脱氮除磷.  相似文献   

13.
李如忠  李峰  周爱佳 《环境科学》2012,33(9):3014-3023
为揭示十五里河水生植物(水花生)生长区沉积物及间隙水营养盐的基本特征,在河道上选择3个具有代表性的采样点位(SP1、SP2和SP3)和1个对照点位(SP4),采集15根沉积物柱状样,并按2 cm厚度现场分层,得到样品80个.在对沉积物TN、TP、NH4+-N、NO3--N、Fe/Al-P、Ca-P、有机质含量及间隙水TN、TP、NH4+-N、NO3--N、PO34--P浓度分析测试基础上,解析沉积物及间隙水的氮磷垂直剖面分布特征,并进行氮磷相关性分析.由间隙水氮磷剖面分布发现,水花生生长区孔隙水氮磷浓度具有大致相似的垂直变化特性;除PO34--P浓度存在差异外,不同采样点位表层沉积物-上覆水界面的营养盐源汇关系,也具有很好的一致性.研究表明,在沉积深度0~18 cm内,水花生生长区的间隙水NH4+-N和NO3--N垂直浓度剖面,基本上都可以由Origin软件提供的Exp2PMod2或Exp3P2指数函数拟合,而PO34--P则不具备这一特点,暗示着间隙水PO34--P扩散的规律性弱于NH4+-N和NO3--N.  相似文献   

14.
A bench-scale cyclic activated sludge technology (CAST) was operated to study the biological phosphorus removal performance and a series of batch tests was carried out to demonstrate the accumulation of denitrifying polyphosphate-accumulating organisms (DNPAOs) in CAST system. Under all operating conditions, step-feed CAST with enough carbon sources in influent had the highest nitrogen and phosphorus removal efficiency as well as good sludge settling performance. The average removal rate of COD, NH4+-N, PO43− -P and total nitrogen (TN) was 88.2%, 98.7%, 97.5% and 92.1%, respectively. The average sludge volume index (SVI) was 133 mL/g. The optimum anaerobic/aerobic/anoxic (AOA) conditions for the cultivation of DNPAOs could be achieved by alternating anoxic/oxic operational strategy, thus a significant denitrifying phosphorus removal occurred in step-feed CAST. The denitrification of NOx− -N completed quickly due to step-feed operation and enough carbon sources, which could enhance phosphorus release and further phosphorus uptake capability of the system. Batch tests also proved that polyphosphate-accumulating organisms (PAOs) in the step-feed process had strong denitrifying phosphorus removal capacity. Both nitrate and nitrite could be used as electron acceptors in denitrifying phosphorus removal. Low COD supply with step-feed operation strategy would favor DNPAOs accumulation.  相似文献   

15.
氧化沟不同曝气模式对氮磷去除性能的优化与比较   总被引:2,自引:1,他引:1  
采用轮流搅拌-曝气SBR系统模拟氧化沟的运行方式,探讨分点曝气和分段曝气对氮磷的去除效果.结果表明,在供气量相同的条件下,分点曝气系统溶氧效率高,一个循环的好氧区比分段曝气系统长,但是分段曝气溶解氧(DO)的有效利用率(用于除氮除磷)高,二者硝化能力相当,氨氮(NH4+-N)去除率分别为96.68%和97.03%,硝化菌活性(以NH4+-N/MLVSS计)分别为4.65和4.66 mg.(g.h)-1.在缺氧区和好氧区比例皆为1时,分点曝气在2、4、7个分区时总氮(TN)去除率分别为60.14%、47.93%和33.7%;总磷(TP)去除率分别为28.96%、23.75%和24.31%,即分区越少,对TN和TP的去除皆有利,但是更利于TN的去除;而分段曝气只有1个分区,其TN和TP的去除率分别为64.21%和49.09%,分段曝气对氮磷的去除效果优于分点曝气,但对提高TP的去除率更有利.对于分段曝气,在满足硝化效果的前提下,增大缺氧区与好氧区的比例,氮磷的去除效率增加.当缺氧区与好氧区的比例由1∶1增大至1.8∶1,其TN和TP的去除率分别提高到73.94%和54.18%.继续增加缺氧区的比例,将影响硝化和运行的稳定,从而影响氮磷的去除效果.  相似文献   

16.
为实现低C/N城市污水与含硝酸盐废水的同步处理,采用SBR接种活性污泥,通过合理控制厌氧/缺氧/低氧时间和溶解氧(DO)浓度,实现了反硝化除磷耦合同步硝化内源反硝化(DPR-SNED)系统的启动,并对启动过程中系统的脱氮除磷特性进行了研究.结果表明采用厌氧/低氧的运行方式,控制厌氧时间为3 h,好氧段DO浓度为0. 5~1. 0 mg·L-1,60 d可实现同步硝化内源反硝化除磷(SNEDPR)系统的启动,出水PO_4~(3-)-P浓度0. 5 mg·L-1,系统氮磷去除率维持在90%以上,COD的去除率维持在80%以上,系统SNED率和CODins率分别维持在70%和95%左右;随后改变运行方式,采用厌氧/缺氧/低氧的方式运行,缺氧段前进含硝酸盐废水,45 d可实现DPR-SNED系统的启动,缺氧末PO_4~(3-)-P浓度1. 1 mg·L-1,出水PO_4~(3-)-P浓度0. 5 mg·L-1,系统磷、COD去除率均维持在90%以上,氮去除率维持在88%以上,系统SNED率和CODins率分别维持在62%和90%左右. DPR-SNED系统的成功启动后,厌氧段聚糖菌和聚磷菌对城市污水有限碳源的充分利用和强化储存,可为后续缺氧段及好氧段的脱氮除磷提供充足的内碳源.此外,DPR-SNED系统缺氧段内源短程反硝化的进行保障了系统在低C/N(4)条件下的高效脱氮.  相似文献   

17.
间歇式曝气生物滤池对焚烧垃圾渗滤液深度脱氮的研究   总被引:2,自引:1,他引:1  
为了提高焚烧垃圾渗滤液深度处理的脱氮效率,构建并启动了间歇式曝气生物滤池(IABF).在曝气阶段停止进水、停曝阶段进水的运行方式下,考察了曝气停曝时间比、运行周期、水力停留时间、碳氮比和气水比对反应器脱氮效率的影响.结果表明,在曝气停曝时间比为1:1,运行周期为1h,水力停留时间8h,COD/TN为4:1,气水比5:1的条件下,IABF取得最佳脱氮效率,平均出水TN可达到19.39 mg·L-1,NH4+-N为9.48 mg·L-1.TN和NH4+-N的平均去除率分别为87.5%和84.1%,出水水质达到《生活垃圾填埋场污染控制标准(GB16889-2008)》.  相似文献   

18.
李冬  魏子清  劳会妹  李帅  张杰 《环境科学》2019,40(12):5456-5464
为实现低C/N城市污水的同步脱氮除磷,采用SBR反应器以厌氧/好氧(A/O)为运行方式,在保持总曝气量900 L不变的条件下调整曝气策略[将均匀曝气2. 81 L·(h·L)-1改为先高强度4. 22 L·(h·L)-1后低强度1. 88 L·(h·L)-1的"高/低曝气"和先低强度1. 88 L·(h·L)-1后高强度4. 22 L·(h·L)-1的"低/高曝气"].试验考察了不同曝气策略下系统的脱氮除磷性能及污泥特性.结果表明,高/低曝气下系统的脱氮除磷效果最佳,出水NH_4+-N、NO_2--N、NO_3--N和TP浓度分别为0、0. 15、8. 12和0. 04 mg·L~(-1),总氮(TN)和总磷(TP)去除率分别为78. 33%和99. 19%,同步硝化内源反硝化(SNED)作用明显,SNED率为77. 08%.且相比于均匀曝气,系统硝化速率及反硝化速率均增加,反硝化速率(以N/VSS计)达到整个运行过程中的最大值,为14. 33 mg·(g·h)-1,同时颗粒污泥密实度、沉降性能及稳定性提高,污泥容积指数(SVI)为23. 49 m L·g~(-1).调整曝气策略为低/高曝气后,系统脱氮除磷性能变差,TN和TP去除率均降至最低,分别为51. 26%和58. 32%,但此时系统硝化性能最佳,氨氧化速率和硝酸盐生成速率均达到整个运行过程中的最大值,分别为14. 92 mg·(g·h)-1和7. 50 mg·(g·h)-1,同时颗粒污泥中丝状菌大量繁殖、结构松散、沉降性及稳定性均变差,SVI升至40. 76 m L·g~(-1).故采取高/低阶梯曝气策略有利于AGS系统高效脱氮除磷及提高稳定性.  相似文献   

19.
同步硝化反硝化耦合除磷工艺的快速启动及其运行特征   总被引:4,自引:4,他引:0  
冷璐  信欣  鲁航  唐雅男  万利华  郭俊元  程庆锋 《环境科学》2015,36(11):4180-4188
以低COD/N生活污水(C/N为3∶1~4∶1)为进水基质,在序批式活性污泥反应器(SBR)中接种好氧颗粒污泥(AGS),通过逐步降低溶解氧(DO)浓度的方式快速实现同步硝化反硝化耦合除磷.反应器运行20 d后(DO浓度为0.50~1.0mg·L-1),系统出现同步硝化反硝化耦合除磷的现象.在随后运行的40 d里,反应器对废水COD、NH+4-N、TN和TP的平均去除率分别为84.84%、93.51%、77.06%和85.69%;出水NO-3-N和NO-2-N平均浓度分别为4.01 mg·L-1和3.17 mg·L-1.反应器启动运行后期,污泥体积指数(SVI)为55.22 m L·g-1,沉降性能良好,颗粒结构较完整.不同氮源的周期曝气阶段结果表明,对TN的去除率为NH+4-NNO-2-NNO-3-N;对TP的去除率为NO-3-NNO-2-NNH+4-N,反应器主要以同步硝化反硝化脱氮和反硝化方式除磷.  相似文献   

20.
亚硝酸盐积累对A~2O工艺生物除磷的影响   总被引:1,自引:1,他引:0  
曾薇  李磊  杨莹莹  张悦  彭永臻 《环境科学》2010,31(9):2105-2112
常温条件下,通过控制好氧区DO浓度为0.3~0.5 mg/L,同时增大系统内回流比以降低系统好氧实际水力停留时间(actual hydraulic retention time,AHRT),在处理低C/N比实际生活污水的A2O工艺中成功启动并维持了短程硝化反硝化.但随着系统出水亚硝酸盐含量的升高,系统对磷的去除效果逐渐恶化.当好氧区亚硝酸盐浓度19 mg/L时,系统出水磷浓度大于进水磷浓度,系统处于净释磷状态.通过对原水COD浓度、反应区温度、pH值、游离亚硝酸浓度(free nitrous acid,FNA)等分析,表明碳源不足及短程硝化引起的亚硝酸盐积累影响了聚磷菌厌氧释磷和好氧吸磷;尤其是好氧区较高的FNA浓度(HNO2-N 0.002~0.003 mg/L)对聚磷菌好氧吸磷的抑制是导致系统除磷效果恶化的直接原因.通过外投碳源提高原水COD浓度,提高了聚磷菌厌氧释磷合成PHA的能力;同时增强了系统的反硝化能力,降低好氧区亚硝酸盐浓度,从而降低FNA对聚磷菌好氧吸磷的抑制程度,系统的除磷性能可迅速恢复;系统对磷的去除率可达96%以上.  相似文献   