首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 171 毫秒
1.
动态膜-生物反应器对城市污水的处理   总被引:43,自引:9,他引:34  
范彬  黄霞  文湘华  于妍 《环境科学》2002,23(6):51-56
应用动态膜原理,以0.1mm孔径的普通筛网代替固定膜材料构成一体式动态膜-生物反应器(DMBR)处理实际城市污水.HRT=3.5h时,出水水质良好.DMBR在小于数cm的液位差下自流出水,出水中的SS最高检测值为4.05mg/L,但在多数情况下为0.在MLSS约7000~8000mg/L下,当动态膜通量为14.9L/(m2·h)时,出水水头仅为5.8mm;27d连续运行,出水水头没有明显改变.动态膜对反应器上清液中的COD和TOC的平均去除率分别为28.74%和36.9%.当溶解氧浓度大于2~3mg/L时,氨氮去除率大于96%.  相似文献   

2.
考查了膜生物反应器处理生活废水的效果 ,研究了抽吸与暂停时间、温度、压力、进水浓度和污泥浓度等因素对出水水质的影响 ,得出最佳因素组合为时间抽吸1 2 min,暂停 2 min,温度 2 0℃左右 ,压力 0 .1 5MPa,ML SS350 0 mg/L时 ,进水浓度的变化对出水水质影响不大。  相似文献   

3.
采用中试规模的中空膜生物床处理混凝沉淀后港口含油废水。进水COD浓度为245544mg/L,当HRT=4h时,出水COD平均浓度为146.5mg/L,平均去除率为64.2%;当HRT=8h时,出水COD平均浓度为133.4mg/L,平均去除率为64.6%。采用活性炭对MBR出水进行深度处理,处理后出水的COD浓度均小于130mg/L,NH4+-N浓度为1.2544mg/L,当HRT=4h时,出水COD平均浓度为146.5mg/L,平均去除率为64.2%;当HRT=8h时,出水COD平均浓度为133.4mg/L,平均去除率为64.6%。采用活性炭对MBR出水进行深度处理,处理后出水的COD浓度均小于130mg/L,NH4+-N浓度为1.24.1mg/L,石油类污染物浓度为0.44.1mg/L,石油类污染物浓度为0.40.9mg/L。MBR稳定运行期间,膜组件的操作负压稳定在0.03MPa以下,远低于化学清洗时的操作负压控制标准0.05Mpa。  相似文献   

4.
气升循环分体式膜生物反应器再生回用厕所污水的研究   总被引:20,自引:0,他引:20  
徐慧芳  樊耀波 《环境科学》2003,24(2):125-129
研究了分体浸没式膜生物反应器及其应用于厕所污水的再生回用.试验结果表明,在人水浓度COD440~970mg/L、BOD5 307~612mg/L、NH3-N59~111mg/L的情况下,出水水质稳定,平均COD<47mg/L、BOD5<8.5mg/L、NH3-N<20mg/L,处理水质达到建设部颁布的生活杂用水回用标准.研究了动力学参数污泥负荷、容积负荷和HRT对出水COD的影响,确定本试验较佳的污泥负荷和容积负荷分别为0.1kg/(kg·d)和1kg/(m3·d),HRT为7~8h.本文对污泥浓度、温度和产水时间与间歇时间比对膜通量的影响进行了测定与探讨.  相似文献   

5.
两段活性污泥法处理味精废水的中试研究   总被引:1,自引:0,他引:1  
白晓慧 《环境工程》2001,19(1):26-27
采用两段活性污泥法处理味精废水 ,试验规模 0 5m3/h ,当进水CODCr浓度 16 80~ 70 30mg/L,NH3 N浓度 2 0 6~ 1999mg/L时 ,经石灰中和 ,空气吹脱对离交废水的预处理后 ,出水CODCr<10 0 0mg/L。试验中 ,兼氧池和一段好氧池污泥浓度保持在 6 0 0 0~ 80 0 0mg/L之间 ,二段好氧池保持在 40 0 0~ 6 0 0 0mg/L之间。生物处理总停留时间 5 0h。在离交废水预处理中 ,pH中和至 9 5~ 10 ,鼓气量在 10 0m3/h左右 ,水温加至 5 5℃左右 ,经 8h ,可将原水NH3 N从12 0 0 0mg/L左右 ,脱除 6 5 %以上 ,出水氨氮可达 40 0 0mg/L左右。  相似文献   

6.
内置转盘式膜-生物反应器处理污水的工艺条件研究   总被引:2,自引:0,他引:2  
吴桂萍  杜春慧  徐又一 《环境科学》2006,27(11):2217-2221
对内置转盘式膜-生物反应器(SRMBR)处理污水工艺进行了研究.进水COD 160~368 mg/L时,出水COD在运行1d后降低到20 mg/L以下,去除率大于90%;转盘式膜组件的转速在0~25 r/min范围内,平衡膜通量随转速增大而快速增加,继续增大转速则平衡膜通量的增加变得不显著;在一定范围(0~1min)内延长停抽时间有助于缓解膜污染;SRMBR在较低的气水比(15∶1)下运行,也可达到较高的平衡膜通量.研究表明,SRMBR在最佳组合操作条件(转速为25r/min,抽/停为9min/1min,气水比为15∶1,抽吸压力为25kPa)下运行,其平衡膜通量高达53.75L/(m2·h).  相似文献   

7.
采用平板膜MBR工艺处理小区生活污水,研究了MBR工艺对COD、BOD、NH4+-N、SS及浊度等去除效果,在进水COD、BOD平均浓度为325mg/L、274mg/L的情况下,出水达到20mg/L和8mg/L,去除率在93%以上,SS及浊度去除率达到100%和98%,NH4+-N去除率79%,出水NH4+-N小于10mg/L。通过研究系统三氮转化可知,该系统没有发生反硝化反应,出水NO2--N和NO3--N浓度较高。通过投加葡萄糖人为改变容积负荷,在容积负荷变化3.2kgCOD/m·3d情况下,系统受负荷冲击影响较小,COD去除率仍能保持在88%以上。通过对膜通量的研究发现,膜通量在连续运行的前3天变化不大,第3天后,膜通量迅速降低,第10天后膜污染达到极限,因此清洗周期设定为3~4天。  相似文献   

8.
PVA膜生物反应器去除效果的研究   总被引:1,自引:0,他引:1  
应用了一种高亲水性的膜材料——PVA膜材料,处理生活污水,在污泥浓度为8000mg/L,HRT为3.5h的条件下,出水COD值维持在20mg/L以下,平均去除率达到93.3%;氨氮去除率达到90%以上;出水SS在1~3mg/L之间,平均去除率达到98.4%,有的甚至能达到100%;出水水质清澈透明,出水浊度平均在0.81NTU,小于1NTU,优于国家饮用水质标准。  相似文献   

9.
考查了膜生物反应器处理生活废水的效果。研究了抽吸与暂停时间,温度,压力,进水浓度和污泥浓度等因素对出水水质的影响,得出最佳因素组合为时间抽吸12min,暂停2min。温度20℃左右,压力0.15MPa,MLSS3500mg/L时,进水浓度的变化对出水水质影响不大。  相似文献   

10.
本研究以实际猪场废水为原料,在中温(37±1)℃条件下利用浸没式平板膜生物反应器进行180d连续厌氧发酵试验,以水力停留时间5,3和2d的梯度变化逐渐增加容积负荷,研究反应器运行性能,污泥比产甲烷活性,膜过滤特性和膜的清洗效果.试验结果表明,随水力停留时间的缩短,反应器的容积产沼气率分别达到0.68,1.03和1.12L/(L·d),稳定运行期间出水的总挥发性脂肪酸分别为(169±41)mg/L,(15±3)mg/L和(114±45)mg/L,以乙酸为主.反应器中厌氧污泥的乙酸比产甲烷活性测试表明,以2000mg/L的乙酸为基质,HRT 3d时具有最大比产甲烷活性1.127g-COD/(g-VSS·d).本试验发生膜污染的周期约4个月.采用2%的柠檬酸浸泡3h,可以恢复膜的过滤性能.在较低通量下,反应器中7~32g/L的污泥浓度并不会明显的影响平板膜的过滤性能.本研究结果显示,厌氧膜生物反应器有处理猪场废水的可能性.  相似文献   

11.
The lack and pollution of water resource make wastewater reuse necessary. The pilot scale long-term tests for submerged membrane bioreactor were conducted to treat the effluents of anaerobic or aerobic treatment process for the high-strength Chinese traditional medicine wastewater. This article was focused on the feasibility of the wastewater treatment and reuse at shorter hydraulic retention time (HRT) of 5.0, 3.2 and 2.13 h. MLSS growth, membrane flux, vacuum values and chemical cleaning periods were also investigated. The experimental results of treating two-phase anaerobic treatment effluent demonstrated that the CODfilt was less than 100 mg/L when the influent COD was between 500-10000 mg/L at HRT of 5.0 h, which could satisfy the normal discharged standard in China. The experimental results to treat cross flow aerobic reactor effluent demonstrated that the average value of CODfilt was 17.28 mg/L when the average value of influent COD was 192.84 mg/L at HRT of 2.13 h during 106 d, which could completely meet the normal standard for water reuse. The maximum MLSS and MLVSS reached 24000 and 14500 mg/L at HRT of 3.2 h respectively. Membrane flux had maximal resume degrees of 94.7% at vacuum value of 0.02 MPa after cleaning. Chemical cleaning periods of membrane module were 150 d. A simulation model of operational parameters was also established based on the theory of back propagation neural network and linear regression of traditional mathematical model. The simulation model showed that the optimum operational parameters were suggested as follows: HRT was 5.0 h, SRT was 100 d, the range of COD loading rate was between 10.664-20.451 kg/(m3.d), the range of MLSS was between 7543-13694 mg/L.  相似文献   

12.
浸没板式MBR处理生活污水造成膜堵塞的关键因素   总被引:3,自引:2,他引:1  
采用浸没板式膜生物反应器对大学学生宿舍与食堂混合排水进行处理,试验系统应用A/O工艺,设置硝化槽与反硝化槽,日处理生活污水4 m3.当进水ρ(BOD5)和ρ(CODCr)分别为90~450和120~900 mg/L时,出水ρ(BOD5)和ρ(CODCr)分别为5~25和8~45 mg/L,去除率均较高.同时对膜污染进行了试验研究,阐述了ρ(MLSS),污泥粒径分布以及原水成分造成膜污染的机理.发现污泥粒径分布随ρ(MLSS)变化而发生改变,当ρ(MLSS)达到20.000 g/L以上时,污泥粒径明显减小,同时可导致膜污染的细微颗粒分布相对增高,这一现象得到ρ(MLSS)超过20.000 g/L时膜污染加剧的试验验证.   相似文献   

13.
IntroductionThedyeingwastewaterofwoolenmillcontainsalotkindsofpollutants,suchasacidicdyes,dispersedyes,mordantdyes,auxiliaries,saltsandsoon .Theeffluentsfromwastewatertreatmentplantsfortreatmentofthedyeingwastewaterofwoolenmillswithnormalbiologicalproce…  相似文献   

14.
An anaerobic/oxic membrane bioreactor (A/O MBR) was used for treatment of dyeing wastewater from a woolen mill.COD and color of the wastewater were 54-473 mg/L and 40-400 dilution time (DT) respectively. The ratio of BOD5/COD was less than 0.13. By the A/O MBR process, the average removal of COD, BOD5, color and turbidity was 82%, 96%, 71% and 99%, respectively. The average COD, BOD5, color and turbidity of effluent was 37 nag/L, 0.8 mg/L, 40 DT and 0.44 NUT respectively. The effluent COD met the local standard of reuse water in Beijing, China. The average COD volume load of the anaerobic biological tank was 0. 0483 kgCOD/(m3·d) and that of the aeration tank of the MBR was 0. 3589 kgCOD/(m3·d). The sludge load of the MBR was 0.19 kgCOD/(kg· MLSS· d) on average and the maximum of that was 0.4 kgCOD/( kg· MLSS· d).The flux of the A/O membrane bioreactor could be remained at larger than 50 L/(h· m2· 0.1MPa). The results indicated that A/O membrane bioreactor has technical feasibility for treatment of woolen mill wastewater.  相似文献   

15.
机械清洗膜组件对膜通量影响的初步研究   总被引:2,自引:0,他引:2  
试验设计了强化机械清洗膜组件M1和机械清洗膜组件M2,通过正交试验考察了污泥浓度、曝气量、运行膜通量和抽吸时间:间歇时间对2组膜组件的膜过滤特性的影响.结果表明,M1膜组件可以弱化不利条件如高污泥浓度(MLSS)、高运行膜通量和低曝气强度的影响;曝气量和运行膜通量是影响膜比通量的主要因素;并得到一组较佳的操作条件组合:污泥浓度6g/L、曝气量0.5m3/h、抽吸时间和间歇时间的比为12:1.在此条件下长期运行试验表明,M1和M2膜通量均可以维持在40L/(h·m2).通过测定2组膜组件的阻力分布,表明机械清洗可以大大减弱膜面泥饼层污染.  相似文献   

16.
采用了膜生物膜工艺处理含盐羧甲基纤维素生产废水。接种污泥为普通污泥,经驯化使其适应含盐废水,在污泥驯化阶段,生物膜表现出极佳的盐度冲击后恢复能力。通过较长的水力停留时间(5~15 d)和较低的COD有机负荷(平均1.6 kg/(m3·d)左右),生物膜COD去除率基本达90%。膜池内,悬浮固体浓度基本保持在5 000 mg/L以内;通过聚偏氟乙烯中空纤维膜过滤,出水悬浮固体浓度保持在5 mg/L以内。膜污染可通过重复的气水反洗和定期的化学清洗得以缓解。  相似文献   

17.
采用超滤-反渗透集成膜技术对酒精废水二级生化处理出水进行深度处理,考察了不同超滤膜对废水的预处理性能,研究了超滤-反渗透集成膜技术对废水污染物的去除效果,并探索了不同清洗方式对反渗透膜通量恢复的影响。试验结果表明:超滤能有效地去除废水浊度和大分子有机物,为反渗透提供良好的进水水质;超滤-反渗透膜系统产水浊度、硬度、总铁均小于0.1 NTU、0.03 mmol/L和0.03 mg/L,电导率处于60~120μS/cm之间,可回用作锅炉补充水;酸洗+碱洗组合清洗方式能有效恢复反渗透膜通量,其废水膜通量可恢复为新膜废水通量的93.75%。  相似文献   

18.
为了考察投加颗粒活性炭(GAC)对膜生物反应器(MBR)运行过程和处理效果的影响,研究了MBR和GAC-MBR透膜压差、膜通量的变化情况和脱氮性能,并采用ASM1模型对2个反应器进行数学模拟.结果表明,MBR和GAC-MBR的运行周期分别为75,150h,说明GAC的加入能够显著减缓MBR膜污染的速度,延长MBR的运行周期.MBR和GAC-MBR氨氮浓度分别为0.5,6mg/L;硝氮浓度分别为4.5,2mg/L;总氮浓度分别为5,10mg/L,出水COD均低于20mg/L,出水能符合《城镇污水处理厂污染物排放标准(GB 18918-2002)》中的一级A标准.采用ASM1进行工艺数学模拟,模拟出水与实际测量值基本吻合,2个反应器中主要微生物为异养菌和氨氧化菌,异养菌在MBR和GAC-MBR中的质量分数分别为95.5%和97.7%;好氧氨氧化菌分别为4.4%和2.3%,说明投加颗粒活性炭能有效的缓解膜污染,并对污染物具有良好的处理效果.  相似文献   

19.
李克林 《环境科技》2005,18(Z1):22-23
为探讨水力停留时间(HRT)对厌氧反应器与好氧MBR组合工艺处理效果的影响,以印染废水为研究对象,进行了实验室研究.结果表明,在溶解氧(DO)浓度为1.8~2.6 mg/L的条件下,HRT为7.5、4.5和2.5 h时,反应器对COD的去除效率分别为88.7%~96.5%、87.3%~97.2%和81%~92%,出水COD的浓度分别为78.9~51.2、81.6~50.8、93.4~65.8 mg/L.试验同时考察了不同HRT条件下,活性污泥浓度(MLSS)对COD去除率的影响.结果表明,在试验条件下,本工艺中一体化膜生物反应器中最佳污泥浓度应控制在6 500 mg/L左右.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号