首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
水力负荷对污水地下渗滤系统处理效果的影响   总被引:3,自引:0,他引:3  
采用人工模拟的方法,研究了0.04、0.06、0.10、0.14和0.18 m3/(m2·d)5个水力负荷下污水地下渗滤系统对生活污水处理效果的影响。实验期间,SS、BOD5、COD、TN、NH+4-N和TP的进水浓度分别处于69.74~79.62、40.75~64.81、211.56~250.72、48.94~87.36、31.25~59.04和2.88~4.05 mg/L之间,出水平均浓度分别为13.63、9.66、31.53、21.08、1.90和0.10 mg/L。结果表明,地下渗滤系统对生活污水具有良好的处理效果,除TN外,其余各项指标均满足《城镇污水处理厂污染物排放标准》(GB/18918-2002)一级处理要求;当水力负荷为0.14和0.18 m3/(m2·d)时,BOD5与TN去除率降低,出水浓度升高,受水力负荷影响明显;水力负荷对SS与COD影响作用微弱,去除率降幅较小;NH+4-N与TP则基本不受水力负荷变化影响。综合考虑渗滤系统的出水水质与日处理能力,推荐适宜水力负荷为0.10~0.14 m3/(m2·d)。  相似文献   

2.
ASBR厌氧氨氧化反应器的快速启动及脱氮原理分析   总被引:3,自引:1,他引:2  
以城市生活污水为基本水质进行配水,采用ASBR研究了厌氧氨氧化反应器的快速启动过程及脱氮性能。实验条件如下:T为(35±1)℃、HRT为24 h、pH为7.2~7.5,进水NH4+-N、NO2--N浓度为40~160 mg/L,TN负荷为0.08~0.34 kg TN/(m3.d),按2∶1比例混合接种好氧短程硝化污泥和厌氧氨氧化污泥,经49 d运行成功启动厌氧氨氧化反应器,并实现稳定运行。实验结果表明:稳定运行期NH4+-N、NO2--N去除率分别达96%和98%;NH4+-N、NO2--N去除量与NO3--N生成量比值为1∶1.05∶0.29,较为接近理论值;成功启动的反应器出水pH高于进水;系统TN去除率平均值为79.7%;反应器内存在反硝化与厌氧氨氧化的协同作用,实现了部分COD去除;污泥由深棕色絮状变成红褐色颗粒状,经SEM扫描电镜观察污泥菌群种类单一,多为球状菌,有漏斗状缺口,具有典型氨氧化菌形态特征。  相似文献   

3.
生物沸石滤池处理富营养化水体的挂膜实验   总被引:3,自引:2,他引:1  
采用上向流生物沸石滤池处理富营养化水体,考察了挂膜阶段(前30 d)滤池对浊度、COD和TP等的去除效果,重点研究了系统中各形态氮素(NH4+-N、NO2--N、NO3--N和TN)的变化情况。结果表明,对于富营养化水体,生物沸石滤池对浊度、COD和TP的去除率分别约为80%、30%和24%;出水NH4+-N始终保持在0.5 mg/L以下,去除率在90%以上;NO2--N出现峰值(4.98 mg/L,第9 d),第13 d后即一直低于进水值;实验后期出水NO3--N与进水NH4+-N变化趋势基本一致,表明硝化生物膜已成熟,原位再生可行;生物沸石床内可能存在同步硝化反硝化现象。出水NO2-N浓度低于进水可作为生物沸石挂膜成功的一个标志。  相似文献   

4.
3种负荷对模拟垂直流人工湿地去除氮、磷效果的影响   总被引:1,自引:0,他引:1  
为探讨水力负荷、有机负荷和悬浮物固体负荷对垂直流人工湿地基质去除氮、磷效果的影响,采用了人工土柱模拟实验的方法,对不同数值的水力负荷、有机负荷(COD)和悬浮固体负荷单因素影响条件下垂直流人工湿地出水中TN、TP的浓度进行了监测。实验结果表明,在3种负荷单一因素影响条件下,垂直流人工湿地处理出水中TN、TP的浓度均随着负荷的增加而增加,即降低水力负荷、有机负荷、悬浮固体负荷均有利于降低垂直流人工湿地处理出水中TN、TP的浓度。当水力负荷为50 cm/d,垂直流人工湿地TP的去除率较高,达到71.52%;当有机负荷为50 g/(m2·d),TN的平均去除率较高,达到41.84%;当悬浮固体负荷为75 g/(m2·d),TP的平均去除率较高,达到92.13%。因此,在水力负荷实验中,当水力负荷为50 cm/d,垂直流人工湿地对氮、磷去除效果较佳;在悬浮固体实验中,当悬浮固体负荷为75 g/m2·d,垂直流人工湿地对氮、磷去除效果较好;在有机负荷实验中,当有机负荷(COD)为50 g/(m2·d),垂直流人工湿地对氮、磷去除效果较好。  相似文献   

5.
反硝化生物滤池深度脱氮机理   总被引:3,自引:0,他引:3  
研究了反硝化生物滤池对污水中硝酸盐氮的脱氮机制及其影响因素。结果表明,在实验室小试条件下,反硝化生物滤池启动14 d后出水基本达到稳定,NO3--N和TN的去除率分别为80%~88%和76%~80%,COD的去除率达到80%以上。稳定运行期,在室温20~29℃、水力负荷为1.5~2 m3/(m2.h)、COD/TN为3.7~4.5的条件下,反应器对NO3--N和TN的去除率分别为70%~85%和47%~64%,且在运行过程中出现了少量NO2--N的积累。分析反硝化生物滤池沿水流方向有机物浓度及氮形态分布发现,沿水流方向NH4+-N浓度基本保持不变;NO2--N浓度在滤层底部至40 cm高处积累较为明显,其后浓度基本不变。  相似文献   

6.
通过中试研究考察了可渗透反应墙(PRB)技术的动态水质净化特性。结果表明:(1)在动态条件下,PRB中试系统中COD、NH4+-N、NO3--N、TN、TP去除率随水力停留时间(HRT)的延长而增加。当HRT为7.00h时,COD、NH4+-N、TN、TP去除率分别为59.4%、26.9%、76.6%、62.2%、82.0%。HRT的延长使难生物降解的有机物也得到部分降解,PRB中试系统中铁屑及新生态的[H]、铁离子的氧化还原作用可以大幅度提高水的可生化性。(2)PRB技术对COD、NH4+-N、TN、TP的去除主要发生在反应区前半段,而且PRB中试系统中COD、NH4+-N、TN、TP沿程的变化情况可用指数方程来描述,动态模型预测曲线拟合较好。同时,对于实际PRB技术工程,PRB技术选择适当的反应介质及介质配比是关键环节。  相似文献   

7.
出水口位置对垂直潜流人工湿地净化的影响   总被引:1,自引:0,他引:1  
研究出水口位置对垂直潜流人工湿地净化的影响。垂直潜流人工湿地以间歇进水方式运行,进水水力负荷为0.125m3/(m2.d),进水来自南宁市琅东污水处理厂初沉池出水。研究结果表明,出水口位置对垂直潜流人工湿地净化有显著影响。与底部出水相比,中部出水的TN、SS和COD去除率分别提高了8.01%、8.48%、7.99%,出水NO-3-N质量浓度降低了9.38 mg/L;但NH+4-N去除率则降低了26.25%,TP去除率降低了21.21%。  相似文献   

8.
研究了生态-人工渗滤组合技术在高速公路收费站生活污水中的处理效果。结果表明:在水力负荷为1.5m3/(m2.d),湿干比为1∶3的条件下,系统对COD、SS、NH4+-N、TP均有较好的去除效果,进水中COD、SS、NH4+-N以及TP浓度分别由126~218、123~186、19.89~32.69、2.75~4.53 mg/L降到出水的8~56、7~28、0.45~1.95和0.12~0.40 mg/L,COD、SS去除率分别在80%、85%以上,NH4+-N、TP的去除率均在90%以上。此研究显示,生态-人工渗滤技术在工程应用良好,基建和运行成本较低,在处理远离城市的生活废水时具有巨大的优势。  相似文献   

9.
研发了一种基于射流曝气的管式反应设备,考察了负荷和DO对反应器处理效能的影响。实验结果表明,在温度为15℃、DO 6.0 mg/L、有机负荷为1.0 kg COD/(m3.d)、氮负荷为0.30 kg TN/(m3.d)、HRT为8 h的条件下,管式反应器可使生活污水的COD、NH4+-N及TN分别从335 mg/L、105 mg/L及110 mg/L降至43 mg/L、14 mg/L及18 mg/L,去除率分别为87%、86%和83%。DO对反应器脱氮效能影响显著,DO为6 mg/L时,能构建出同步硝化反硝化系统,NH4+-N和TN的去除率分别为96.6%和86.7%。  相似文献   

10.
低浓度氨氮废水在ABR中的厌氧氨氧化研究   总被引:6,自引:0,他引:6  
在低浓度氨氮条件下利用厌氧折流板反应器(anaerobic baffled reactor,ABR)以厌氧污泥混合河涌底泥为接种源启动厌氧氨氧化(anaerobic ammonium oxidation,anammox)反应。系统连续运行4个月后出水趋于稳定,当NH3-N和NO2--N容积负荷分别为3.91 g/(m3.d)和3.21 g/(m3.d)时,平均去除率分别为85.7%和98.8%。利用荧光原位杂交(fluorescence in situ hybridization,FISH)技术对ABR厌氧污泥进行了分析。随后,以缩短HRT或增加进水NH3-N和NO2?-N浓度的方式来逐步提高反应器运行负荷,最后当NH3-N和NO2--N容积负荷分别达到65.53 g/(m3.d)和68.46 g/(m3.d)时,平均去除率为76.3%和91.3%,并培育出粒径为1.7~2.5 mm的颗粒污泥。利用扫描电镜(SEM)观察培育得到颗粒污泥与接种颗粒污泥,发现经驯化的ABR系统内微生物种类已变得较为单一,优势菌群发生明显变化。  相似文献   

11.
两级混合稳定表流湿地处理生活污水   总被引:1,自引:1,他引:0  
为了提高一级稳定表流湿地(stable surface flow wetland,SSFW)的出水水质,在单级稳定表流湿地后串联一级潜流人工湿地,构成两级混合稳定表流湿地(two steps hybrid stable surface flow wetland,TSHSSFW),研究气候变化对其净化效果的影响,并同一级潜流人工湿地(one step subsurface flow wetland,OSSFW)进行对比。研究表明,气候变化对TSHSSFW的COD和总磷去除率影响较小,去除率均在80%左右;而对氨氮和总氮的去除率影响比较大,夏季TSHSSFW的氨氮和总氮去除率分别为87.77%和77.74%,而冬季氨氮和总氮的去除率分别为54.07%和48.84%。相比单级潜流人工湿地(OSSFW),有SSFW作为前处理的潜流人工湿地对氨氮和总氮的去除率较高。  相似文献   

12.
Nitrogen removal processing in different constructed wetlands treating different kinds of wastewater often varies, and the contribution to nitrogen removal by various pathways remains unclear. In this study, the seasonal nitrogen removal and transformations as well as nitrogen balance in wetland microcosms treating slightly polluted river water was investigated. The results showed that the average total nitrogen removal rates varied in different seasons. According to the mass balance approach, plant uptake removed 8.4–34.3 % of the total nitrogen input, while sediment storage and N2O emission contributed 20.5–34.4 % and 0.6–1.9 % of nitrogen removal, respectively. However, the percentage of other nitrogen loss such as N2 emission due to nitrification and denitrification was estimated to be 2.0–23.5 %. The results indicated that plant uptake and sediment storage were the key factors limiting nitrogen removal besides microbial processes in surface constructed wetland for treating slightly polluted river water.  相似文献   

13.
A pilot-scale constructed wetland (CW) system, combining a free water surface wetland and a subsurface wetland in series, was used to purify highly polluted river water. The concentrations of constituents varied seasonally. The effects of season-dependent parameters, such as temperature, mass loading rate and inflow salinity, on the removal of ammonia nitrogen (AN) in the wetland system were examined at a constant hydraulic loading rate, based on data from June 1998 to February 2000. AN removal of the CW varied cyclically with the seasons. The removal efficiency and the first-order volumetric removal rate constant (k(V)) increased exponentially with water temperature, yielding a high temperature coefficient (theta). However, the mass removal rate decreased exponentially as temperature increased. These contradictory results made the actual effect of temperature uncertain. The inhibition of high water salinity on AN removal was also unclear because k(V) (as well as k(V20)) and mass removal rate were inversely proportional to salinity. However, mass loading rate (MLR) predominantly affected both the removal efficiency and the mass removal rate of AN, both of which were factors that explicitly determined seasonality. A power equation, k(V20)' alpha MLR(-n), was proposed to correct the variation of the mass loading rate in estimating k(V) and thus in designing a constructed wetland.  相似文献   

14.
水深对表面流人工湿地污染河水处理系统运行效果的影响   总被引:4,自引:0,他引:4  
基于中试系统一年的连续运行监测,研究了水深对芦苇表面流人工湿地污染河水处理系统的影响。结果表明,水深对表面流人工湿地污染河水处理系统运行效果有很大影响,在进水COD、氨氮、总氮和总磷等分别为36±4.46、0.92±0.47、6.27±2.01和0.13±0.05 mg/L条件下,水深50 cm时处理效果最好,COD、氨氮、总氮和总磷去除率分别达到42.75%、58.42%、56.94%和43.24%。综合污染物去除效果和人工湿地建设工程量,芦苇表面流人工湿地的水深宜采用50 cm。人工湿地系统中植物光合生理和溶解氧等研究表明,水深主要通过影响植物生长和溶解氧等而影响人工湿地的水质净化效果。  相似文献   

15.
复合型人工湿地越来越多地被应用在面源污染管理中。不同类型的人工湿地对氮素的去除机理和去除性能是不同的。氮素在湿地生态系统中的去除受多种因素的影响和制约,不同的研究中氮素的去除效率变化较大。通过对韩国西部一复合型人工湿地中氮素的去除能力研究,分析了氮素的去除效率以及水力负荷对去除性能的影响,进而分析了人工湿地去除氮素的主要机理。结果表明,氨氮(NH+4-N)、硝酸盐氮(NO-3-N)、凯式氮(TKN)和总氮(TN)的平均去除效率分别为13%、29%、35.3和26%。其中有机氮的去除是该复合型人工湿地中氮素去除的主要原因。水力负荷和先行干期天数对氮素的去除能力有一定影响。较长的先行干期天数和较低水力负荷可以提高氮素的去除效率。  相似文献   

16.
在比较了不同基质脱氮效率的基础上,认为基质作为人工湿地的重要组成部分,在为植物和微生物提供生长介质的同时,也能通过沉淀、过滤和吸附等作用直接去除污染物质,其中基质的类型、级配等因素会影响基质作用的发挥;不同基质对脱氮性能存在较大差异,沸石和蛭石是目前研究中脱氮效率较高的两种基质。在归纳了脱氮机制和影响因素的基础上,认为不同基质由于脱氮机制不同,脱氮性能和脱氮效率也存在较大差异;人工湿地基质所有理化性状都可能影响到它对污水的脱氮效率。最后,对今后的相关研究方向进行了展望。  相似文献   

17.
2种人工湿地的水力停留时间及净化效果   总被引:2,自引:0,他引:2  
以复合垂直流人工湿地(IVCW)和水平潜流人工湿地(HSCW)为研究对象,研究了2种湿地运行的季节性最佳水力停留时间(HRT)参数,并监测了2种湿地在最佳HRT参数下运行时对污水的净化效果。结果显示:(1)在IVCW中,最佳HRT在春、秋季为8~10 h;夏季为6 h;冬季为12 h。在HSCW中,最佳HRT在春、秋季为10~12 h;夏季为6~8h;冬季为24~36 h。(2)2种湿地对COD的去除率均无显著的季节性差异;湿地进水中NH4+-N/TN比值与TN去除率显著负相关;不同季节下IVCW对TN的去除效果均高于HSCW。(3)水温对TN、TP去除率的影响在IVCW中比HSCW中的明显;水温高时,2种湿地中的TN去除率较高,IVCW中的TP去除率也较高,但HSCW中的TP去除率则较低,它们间均未达到显著的相关性。  相似文献   

18.
间歇曝气潜流人工湿地的污水脱氮效果   总被引:3,自引:0,他引:3  
采用间歇曝气运行方式,提升潜流人工湿地生活污水处理系统中的溶解氧浓度,强化脱氮效果。结果表明,间歇曝气运行方式有效提高了湿地内部溶解氧水平,曝气时溶解氧浓度可达6~9 mg/L,停止曝气后,溶解氧浓度迅速下降至0.5 mg/L以下,在湿地内部营造了一种交替的好氧和缺氧环境,分别促进好氧硝化和缺氧反硝化作用。在水力停留时间为3 d的情况下,间歇曝气潜流人工湿地系统对氨氮、总氮和COD的去除率分别可达到98.0%、87.6%和96.3%,较常规潜流人工湿地系统分别提高了74.1%、56.4%和18.1%,实现了氨氮、总氮和COD的同步高效去除。  相似文献   

19.
构建了潮汐流-潜流组合和潜流-潮汐流组合人工湿地对污水进行处理,分别研究2种组合人工湿地对污水的净化效果。结果表明,在平均进水COD浓度为214.28mg/L、NH4+-N浓度为10.57mg/L、PO34--P浓度为5.44mg/L、TN浓度为10.25mg/L,水力负荷为o.2m3/(m2·d)的条件下,潮汐流-潜流组合人工湿地对COD、PO34--P的去除率分别为58.28%和46.99%,与潜流-潮汐流组合人工湿地处理效果相近;对NH4+-N、TN,潮汐流-潜流组合人工湿地的去除率分别为69.93%和71.03%,比潜流-潮汐流组合人工湿地分别高15%和33%。潮汐流-潜流人工湿地的组合,在系统内实现了硝化-反硝化的组合,强化了系统对TN的净化效果,其对TN的净化效果比-般的潜流和表面流人工湿地组合提高20%~30%。总体上,潮汐流-潜流组合人工湿地具有更好的净化效果。  相似文献   

20.
采用聚合酶链反应(PCR)—变性梯度凝胶电泳(DGGE)技术对梯田式人工湿地(TTCW)和复合垂直流式人工湿地(IVCW)生活污水处理系统内的微生物群落结构的动态变化及其对生活污水处理效果的影响进行了对比研究。结果表明:(1)TTCW和IVCW对生活污水均具有较好处理效果,其COD去除率平均分别为76.2%和72.6%、TP去除率平均分别为90.7%和85.6%、NH4+-N去除率平均分别为65.2%和58.8%;TTCW增氧作用明显。(2)2种人工湿地内均存在丰富的微生物群落,并均存在共有的微生物种群;在湿地沿程不同位置均存在一定数量的优势种群。(3)TTCW强化了大气复氧能力,使得湿地内DO较相同深度的IVCW的高。TTCW具有较强的污染物去除能力,特别是具有高效的脱氮除磷能力。这种能力可能主要是TTCW中微生物群落结构的变化所致。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号