首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We monitored two Seattle school buses to quantify the buses’ self pollution using the dual tracers (DT), lead vehicle (LV), and chemical mass balance (CMB) methods. Each bus drove along a residential route simulating stops, with windows closed or open. Particulate matter (PM) and its constituents were monitored in the bus and from a LV. We collected source samples from the tailpipe and crankcase emissions using an on-board dilution tunnel. Concentrations of PM1, ultrafine particle counts, elemental and organic carbon (EC/OC) were higher on the bus than the LV. The DT method estimated that the tailpipe and the crankcase emissions contributed 1.1 and 6.8 μg m?3 of PM2.5 inside the bus, respectively, with significantly higher crankcase self pollution (SP) when windows were closed. Approximately two-thirds of in-cabin PM2.5 originated from background sources. Using the LV approach, SP estimates from the EC and the active personal DataRAM (pDR) measurements correlated well with the DT estimates for tailpipe and crankcase emissions, respectively, although both measurements need further calibration for accurate quantification. CMB results overestimated SP from the DT method but confirmed crankcase emissions as the major SP source. We confirmed buses’ SP using three independent methods and quantified crankcase emissions as the dominant contributor.  相似文献   

2.
Authors’ Reply     
ABSTRACT

Exposures of occupants in school buses to on-road vehicle emissions, including emissions from the bus itself, can be substantially greater than those in outdoor settings. A dual tracer method was developed and applied to two school buses in Seattle in 2005 to quantify in-cabin fine particulate matter (PM2.5) concentrations attributable to the buses' diesel engine tailpipe (DPMtp) and crankcase vent (PMck) emissions. The new method avoids the problem of differentiating bus emissions from chemically identical emissions of other vehicles by using a fuel-based organometallic iridium tracer for engine exhaust and by adding deuterated hexatriacontane to engine oil. Source testing results showed consistent PM:tracer ratios for the primary tracer for each type of emissions. Comparisons of the PM:tracer ratios indicated that there was a small amount of unburned lubricating oil emitted from the tailpipe; however, virtually no diesel fuel combustion products were found in the crankcase emissions. For the limited testing conducted here, although PMck emission rates (averages of 0.028 and 0.099 g/km for the two buses) were lower than those from the tailpipe (0.18 and 0.14 g/km), in-cabin PMck concentrations averaging 6.8 μg/m3 were higher than DPMtp (0.91 μg/m3 average). In-cabin DPMtp and PMck concentrations were significantly higher with bus windows closed (1.4 and 12 μg/m3, respectively) as compared with open (0.44 and 1.3 μg/m3, respectively). For comparison, average closed- and open-window in-cabin total PM2.5 concentrations were 26 and 12 μg/m3, respectively. Despite the relatively short in-cabin sampling times, very high sensitivities were achieved, with detection limits of 0.002 μg/m3 for DPMtp and 0.05 μg/m3 for PMck.

IMPLICATIONS PM2.5 measurements in two Seattle school buses showed average concentrations of 26 and 12 μg/m3 with windows closed and open, respectively. Virtually all PM2.5 was car bonaceous. Tracer measurements showed that bus self-pollution contributed approximately 50% of total PM2.5 concentrations with windows closed and 15% with windows open, with over three-quarters of these contributions attributed to crankcase emissions. Maintaining ventilation in buses clearly reduces total PM2.5 exposures and that from the buses' own emissions. The dual tracer method now offers researchers a new technique for explicit identification of single source contributions in settings with multiple sources of carbonaceous emissions.  相似文献   

3.
Abstract

Real‐time concentrations of black carbon, particle‐bound polycyclic aromatic hydrocarbons, nitrogen dioxide, and fine particulate counts, as well as integrated and real‐time fine particulate matter (PM2.5) mass concentrations were measured inside school buses during long commutes on Los Angeles Unified School District bus routes, at bus stops along the routes, at the bus loading/unloading zone in front of the selected school, and at nearby urban “background” sites. Across all of the pollutants, mean concentrations during bus commutes were higher than in any other microenvironment. Mean exposures (mean concentration times time spent in a particular microenvironment) in bus commutes were between 50 and 200 times greater than those for the loading/unloading microenvironment, and 20–40 times higher than those for the bus stops, depending on the pollutant. Although the analyzed school bus commutes represented only 10% of a child’s day, on average they contributed one‐third of a child’s 24‐hr overall black carbon exposure during a school day. For species closely related to vehicle exhaust, the within‐cabin exposures were generally dominated by the effect of surrounding traffic when windows were open and by the bus’s own exhaust when windows were closed. Low‐emitting buses generally exhibited high concentrations only when traveling behind a diesel vehicle, whereas high‐emitting buses exhibited high concentrations both when following other diesel vehicles and when idling without another diesel vehicle in front of the bus. To reduce school bus commute exposures, we recommend minimizing commute times, avoiding caravanning with other school buses, using the cleanest buses for the longest bus routes, maintaining conventional diesel buses to eliminate visible emissions, and transitioning to cleaner fuels and advanced particulate control technologies as soon as possible.  相似文献   

4.
This paper presents results from an in-vehicle air quality study of public transit buses in Toledo, Ohio, involving continuous monitoring, and experimental and statistical analyses to understand in-vehicle particulate matter (PM) behavior inside buses operating on B20-grade biodiesel fuel. The study also focused on evaluating the effects of vehicle’s fuel type, operating periods, operation status, passenger counts, traffic conditions, and the seasonal and meteorological variation on particulates with aerodynamic diameter less than 1 micron (PM1.0). The study found that the average PM1.0 mass concentrations in B20-grade biodiesel-fueled bus compartments were approximately 15 μg m?3, while PM2.5 and PM10 concentration averages were approximately 19 μg m?3 and 37 μg m?3, respectively. It was also observed that average hourly concentration trends of PM1.0 and PM2.5 followed a “μ-shaped” pattern during transit hours.Experimental analyses revealed that the in-vehicle PM1.0 mass concentrations were higher inside diesel-fueled buses (10.0–71.0 μg m?3 with a mean of 31.8 μg m?3) as compared to biodiesel buses (3.3–33.5 μg m?3 with a mean of 15.3 μg m?3) when the windows were kept open. Vehicle idling conditions and open door status were found to facilitate smaller particle concentrations inside the cabin, while closed door facilitated larger particle concentrations suggesting that smaller particles were originating outside the vehicle and larger particles were formed within the cabin, potentially from passenger activity. The study also found that PM1.0 mass concentrations at the back of bus compartment (5.7–39.1 μg m?3 with a mean of 28.3 μg m?3) were higher than the concentrations in the front (5.7–25.9 μg m?3 with a mean of 21.9 μg m?3), and the mass concentrations inside the bus compartment were generally 30–70% lower than the just-outside concentrations. Further, bus route, window position, and time of day were found to affect the in-vehicle PM concentrations significantly. Overall, the in-vehicle PM1.0 concentrations inside the buses operating on B20-grade biodiesel ranged from 0.7 μg m?3 to 243 μg m?3, with a median of 11.6 μg m?3.Statistical models developed to study the effects of vehicle operation and ambient conditions on in-vehicle PM concentrations suggested that while open door status was the most important influencing variable for finer particles and higher passenger activity resulted in higher coarse particles concentrations inside the vehicle compartments, ambient PM concentrations contributed to all PM fractions inside the bus irrespective of particle size.  相似文献   

5.
Atmospheric particles are a major problem that could lead to harmful effects on human health, especially in densely populated urban areas. Chiayi is a typical city with very high population and traffic density, as well as being located at the downwind side of several pollution sources. Multiple contributors for PM2.5 (particulate matter with an aerodynamic diameter ≥2.5 μm) and ultrafine particles cause complicated air quality problems. This study focused on the inhibition of local emission sources by restricting the idling vehicles around a school area and evaluating the changes in surrounding atmospheric PM conditions. Two stationary sites were monitored, including a background site on the upwind side of the school and a campus site inside the school, to monitor the exposure level, before and after the idling prohibition. In the base condition, the PM2.5 mass concentrations were found to increase 15% from the background, whereas the nitrate (NO3?) content had a significant increase at the campus site. The anthropogenic metal contents in PM2.5 were higher at the campus site than the background site. Mobile emissions were found to be the most likely contributor to the school hot spot area by chemical mass balance modeling (CMB8.2). On the other hand, the PM2.5 in the school campus fell to only 2% after idling vehicle control, when the mobile source contribution reduced from 42.8% to 36.7%. The mobile monitoring also showed significant reductions in atmospheric PM2.5, PM0.1, polycyclic aromatic hydrocarbons (PAHs), and black carbon (BC) levels by 16.5%, 33.3%, 48.0%, and 11.5%, respectively. Consequently, the restriction of local idling emission was proven to significantly reduce PM and harmful pollutants in the hot spots around the school environment.

Implications: The emission of idling vehicles strongly affects the levels of particles and relative pollutants in near-ground air around a school area. The PM2.5 mass concentration at a campus site increased from the background site by 15%, whereas NO3? and anthropogenic metals also significantly increased. Meanwhile, the PM2.5 contribution from mobile source in the campus increased 6.6% from the upwind site. An idling prohibition took place and showed impressive results. Reductions of PM2.5, ionic component, and non-natural metal contents were found after the idling prohibition. The mobile monitoring also pointed out a significant improvement with the spatial analysis of PM2.5, PM0.1, PAH, and black carbon concentrations. These findings are very useful to effectively improve the local air quality of a densely city during the rush hour.  相似文献   

6.
Concentrations of ultrafine (<0.1 μm) particles (UFPs) and PM2.5 (<2.5 μm) were measured whilst commuting along a similar route by train, bus, ferry and automobile in Sydney, Australia. One trip on each transport mode was undertaken during both morning and evening peak hours throughout a working week, for a total of 40 trips. Analyses comprised one-way ANOVA to compare overall (i.e. all trips combined) geometric mean concentrations of both particle fractions measured across transport modes, and assessment of both the correlation between wind speed and individual trip means of UFPs and PM2.5, and the correlation between the two particle fractions. Overall geometric mean concentrations of UFPs and PM2.5 ranged from 2.8 (train) to 8.4 (bus) × 104 particles cm?3 and 22.6 (automobile) to 29.6 (bus) μg m?3, respectively, and a statistically significant difference (p < 0.001) between modes was found for both particle fractions. Individual trip geometric mean concentrations were between 9.7 × 103 (train) and 2.2 × 105 (bus) particles cm?3 and 9.5 (train) to 78.7 (train) μg m?3. Estimated commuter exposures were variable, and the highest return trip mean PM2.5 exposure occurred in the ferry mode, whilst the highest UFP exposure occurred during bus trips. The correlation between fractions was generally poor, and in keeping with the duality of particle mass and number emissions in vehicle-dominated urban areas. Wind speed was negatively correlated with, and a generally poor determinant of, UFP and PM2.5 concentrations, suggesting a more significant role for other factors in determining commuter exposure.  相似文献   

7.
Commuters’ exposure measurements were taken for PM2.5, carbon monoxide (CO) and benzene in minibuses, buses and metro during morning and evening rush hours during January–March 2003 in Mexico City. For PM2.5, the chemical composition was characterized. Total carbon was the most abundant species in fine particles (approximately 50%). Minibuses (49 μg m−3) and buses had similar concentrations of exposure for PM2.5 (53 μg m−3). For CO and benzene the concentrations were higher in minibuses. Morning rush hour was the commuting period with the highest concentrations for minibuses and buses. Metro was the mode of transport with lower concentrations for all pollutants. Carbon monoxide concentrations were similar to those identified in a previous campaign in 2002 and approximately 3.5 times lower than those in a study conducted in 1991. Benzene was characterized systematically in the selected modes of transport. A strong association was observed between wind speed and pollutant concentrations in buses.  相似文献   

8.
This study evaluates the effect of retrofit closed crankcase ventilation filters (CCFs) and diesel oxidation catalysts (DOCs) on the in-cabin air quality in transit-style diesel school buses. In-cabin pollution levels were measured on three buses from the Pueblo, CO District 70 fleet. Monitoring was conducted while buses were driven along their regular routes, with each bus tested three times before and three times after installation of control devices. Ultrafine number concentrations in the school bus cabins were 33–41% lower, on average, after the control devices were installed. Mean mass concentrations of particulate matter less than 2.5 μm in diameter (PM2.5) were 56% lower, organic carbon (OC) 41% lower, elemental carbon (EC) 85% lower, and formaldehyde 32% lower after control devices were installed. While carbon monoxide concentrations were low in all tests, mean concentrations were higher after control devices were installed than in pre-retrofit tests. Reductions in number, OC, and formaldehyde concentrations were statistically significant, but reductions in PM2.5 mass were not. Even with control devices installed, during some runs PM2.5 and OC concentrations in the bus cabins were elevated compared to ambient concentrations observed in the area. OC concentrations inside the bus cabins ranged from 22 to 58 μg m?3 before and 13 to 33 μg m?3 after control devices were installed. OC concentrations were correlated with particle-bound organic tracers for lubricating oil emissions (hopanes) and diesel fuel and tailpipe emissions (polycyclic aromatic hydrocarbons (PAH) and aliphatic hydrocarbons). Mean concentrations of hopanes, PAH, and aliphatic hydrocarbons were lower by 37, 50, and 43%, respectively, after the control devices were installed, suggesting that both CCFs and DOCs were effective at reducing in-cabin OC concentrations.  相似文献   

9.
This research evaluates commuter exposure to particulate matter during pre-journey commute segments for passengers waiting at bus stops by investigating 840 min of simultaneous exposure levels, both inside and outside seven bus shelters in Buffalo, New York. A multivariate regression model is used to estimate the relation between exposure to particulate matter (PM2.5 measured in μg m?3) and three vectors of determinants: time and location, physical setting and placement, and environmental factors. Four determinants have a statistically significant effect on particulate matter: time of day, passengers’ waiting location, land use near the bus shelter, and the presence of cigarette smoking at the bus shelter. Model results suggest that exposure to PM2.5 inside a bus shelter is 2.63 μg m?3 (or 18 percent) higher than exposure outside a bus shelter, perhaps due in part to the presence of cigarette smoking. Morning exposure levels are 6.51 μg m?3 (or 52 percent) higher than afternoon levels. Placement of bus stops can affect exposure to particulate matter for those waiting inside and outside of shelters: air samples at bus shelters located in building canyons have higher particulate matter than bus shelters located near open space.  相似文献   

10.
Real-time concentrations of black carbon, particle-bound polycyclic aromatic hydrocarbons, nitrogen dioxide, and fine particulate counts, as well as integrated and real-time fine particulate matter (PM2.5) mass concentrations were measured inside school buses during long commutes on Los Angeles Unified School District bus routes, at bus stops along the routes, at the bus loading/unloading zone in front of the selected school, and at nearby urban "background" sites. Across all of the pollutants, mean concentrations during bus commutes were higher than in any other microenvironment. Mean exposures (mean concentration times time spent in a particular microenvironment) in bus commutes were between 50 and 200 times greater than those for the loading/unloading microenvironment, and 20-40 times higher than those for the bus stops, depending on the pollutant. Although the analyzed school bus commutes represented only 10% of a child's day, on average they contributed one-third of a child's 24-hr overall black carbon exposure during a school day. For species closely related to vehicle exhaust, the within- cabin exposures were generally dominated by the effect of surrounding traffic when windows were open and by the bus's own exhaust when windows were closed. Low-emitting buses generally exhibited high concentrations only when traveling behind a diesel vehicle, whereas high-emitting buses exhibited high concentrations both when following other diesel vehicles and when idling without another diesel vehicle in front of the bus. To reduce school bus commute exposures, we recommend minimizing commute times, avoiding caravanning with other school buses, using the cleanest buses for the longest bus routes, maintaining conventional diesel buses to eliminate visible emissions, and transitioning to cleaner fuels and advanced particulate control technologies as soon as possible.  相似文献   

11.
Although airborne pollutants in urban buses have been studied in many cities globally, long-distance buses running mainly on highways have not been addressed in this regard. This study investigates the levels of volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2) and particulate matter (PM) in the long-distance buses in Taiwan. Analytical results indicate that pollutants levels in long-distance buses are generally lower than those in urban buses. This finding is attributable to the driving speed and patterns of long-distance buses, as well as the meteorological and geographical features of the highway surroundings. The levels of benzene, toluene, ethylbenzene and xylene (BTEX) found in bus cabins exceed the proposed indoor VOC guidelines for aromatic compounds, and are likely attributable to the interior trim in the cabins. The overall average CO level is 2.3 ppm, with higher average level on local streets (2.9 ppm) than on highways (2.2 ppm). The average CO2 level is 1493 ppm, which is higher than the guideline for non-industrial occupied settings. The average PM level in this study is lower than those in urban buses and IAQ guidelines set by Taiwan EPA. However, the average PM10 and PM2.5 is higher than the level set by WHO. Besides the probable causes mentioned above, fewer passenger movements and less particle re-suspension from bus floor might also cause the lower PM levels. Measurements of particle size distribution reveal that more than 75% of particles are in submicron and smaller sizes. These particles may come from the infiltration from the outdoor air. This study concludes that air exchange rates in long-distance buses should be increased in order to reduce CO2 levels. Future research on long-distance buses should focus on the emission of VOCs from brand new buses, and the sources of submicron particles in bus cabins.  相似文献   

12.
Average 21st century concentrations of urban air pollutants linked to cardiorespiratory disease are not declining, and commonly exceed legal limits. Even below such limits, health effects are being observed and may be related to transient daytime peaks in pollutant concentrations. With this in mind, we analyse >52,000 hourly urban background readings of PM10 and pollutant gases throughout 2007 at a European town with legal annual average concentrations of common pollutants, but with a documented air pollution-related cardiorespiratory health problem, and demonstrate the hourly variations in PM10, SO2, NOx, CO and O3. Back-trajectory analysis was applied to track the arrival of exotic PM10 intrusions, the main controls on air pollutants were identified, and the typical hourly pattern on ambient concentrations during 2007 was profiled. Emphasis was placed on “worst case” data (>90th percentile), when health effects are likely to be greatest. The data show marked daytime variations in pollutants result from rush-hour traffic-related pollution spikes, midday industrial SO2 maxima, and afternoon O3 peaks. African dust intrusions enhance PM10 levels at whatever hour, whereas European PM incursions produce pronounced evening peaks due to their transport direction (across an industrial traffic corridor). Transient peak profiling moves us closer to the reality of personal outdoor exposure to inhalable pollutants in a given urban area. We argue that such an approach to monitoring data potentially offers more to air pollution health effect studies than using only 24 h or annual averages.  相似文献   

13.
Previous studies have explored the association between air pollution levels and adverse birth outcomes such as lower birth weight. Existing literature suggests an association, although results across studies are not consistent. Additional research is needed to confirm the effect, investigate the exposure window of importance, and distinguish which pollutants cause harm.

We assessed the association between ambient pollutant concentrations and term birth weight for 1,548,904 births in TX from 1998 to 2004. Assignment of prenatal exposure to air pollutants was based on maternal county of residence at the time of delivery. Pollutants examined included particulate matter with aerodynamic diameter ≤10 and ≤2.5 µm (PM10 and PM2.5), sulfur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO), and ozone (O3). We applied a linear model with birth weight as a continuous variable. The model was adjusted for known risk factors and region. We assessed pollutant effects by trimester to identify biological exposure window of concern, and explored interaction due to race/ethnicity.

An interquartile increase in ambient pollutant concentrations of SO2 and O3 was associated with a 4.99-g (95% confidence interval [CI], 1.87–8.11) and 2.72-g (95% CI, 1.11–4.33) decrease in birth weight, respectively. Lower birth weight was associated with exposure to O3 in the first and second trimester, whereas results were not significant for other pollutants by trimester. A positive association was exhibited for PM2.5 in the first trimester. Effects estimates for PM10 and PM2.5 were inconsistent across race/ethnic groups.

Current ambient air pollution levels may be increasing the risk of lower birth weight for some pollutants. These risks may be increased for certain racial/ethnic groups. Additional research including consideration of improved methodology is needed to investigate these findings. Future studies should examine the influence of residual confounding.

Implications: This is one of the most comprehensive studies examining criteria air pollutants and lower birth weight in Texas. Our findings confirm results found previously for adverse effects of the air pollutant SO2 on lower birth weight. Results from our study suggest that adverse pregnancy outcomes such as lower birth weight can occur even while maintaining air pollution levels below regulatory standards. Future studies should incorporate the assessment of differential pollutant exposure as well as effect estimates by race/ethnicity with individual and community-level social factors in order to enhance our understanding of how physical, social, and host factors influence birth outcomes.

Supplemental Materials: Supplementary information relating to characteristics of excluded births, distribution of air pollutant monitors by pollutant, and correlation coefficients of the air pollutants is available in the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

14.
This study attempts to determine the influence of air quality in a residential area near a medical waste incineration plant. Ambient air concentrations of polycyclic aromatic hydrocarbons (PAHs), PM10 and PM2.5 (PM—particulate matter) were determined by collecting air samples in areas both upwind and downwind of the plant. The differences in air pollutant levels between the study area and a reference area 11 km away from the plant were evaluated.Dichotomous samplers were used for sampling PM2.5 and PM10 from ambient air. Two hundred and twenty samples were obtained from the study area, and 100 samples were taken from a reference area. Samples were weighed by an electronic microbalance and concentrations of PM2.5 and PM10 were determined. A HPLC equipped with a fluorescence detector was employed to analyze the concentrations of 15 PAHs compounds adsorbed into PM2.5 and PM10.The experimental results indicated that the average concentrations of PM2.5 and PM10 were 30.34±17.95 and 36.81±20.45 μg m−3, respectively, in the study area, while the average ratio of PM2.5/PM10 was 0.82±0.01. The concentrations of PM2.5 and PM10 of the study area located downwind of the incinerator were significantly higher than the study area upwind of the incinerator (P<0.05).The concentration of PAHs in PM2.5 in the study area was 2.2 times higher than in the reference area (P<0.05). Furthermore, the benzo(a)pyrene concentrations in PM2.5 and PM10 were 0.11±0.05 ng m−3 and 0.12±0.06 ng m−3 in the study area, respectively. The benzo(a)pyrene concentrations of PM2.5 and PM10 in the study area were 7 and 5.3 times higher than in the reference area (P<0.05), respectively.The study indicated that the air quality of PM2.5, PM10 and PAHs had significant contamination by air pollutants emitted from a medical waste incineration factory, representing a public health problem for nearby residences, despite the factory being equipped with a modern air pollution control system.  相似文献   

15.
16.
Several studies have investigated the health of children attending schools located near busy roads. In this study, we have measured personal exposure to traffic-related pollutants in children to validate exposure classification based on school location. Personal exposure to PM2.5, soot, NOx and NO2 was measured during four 48-h periods. The study involved 54 children attending four different schools, two of which were located within 100 m of a major road (one ring road and one freeway) and the other two were located at a background location in the city of Utrecht, The Netherlands. Outdoor monitoring was conducted at all school sites, during the personal measurements. A questionnaire was administered on time activity patterns and indoor sources at home. The outdoor concentration of soot was 74% higher at the freeway school compared to its matched background school. Personal exposure to soot was 30% higher. For NOx the outdoor concentration was 52% higher at the freeway school compared to its background school. The personal concentration of NOx was 37% higher for children attending the freeway school. Differences were smaller and insignificant for PM2.5 and NO2. No elevated personal exposure to air pollutants was found for the children attending the school near the ring road. We conclude that the school's proximity to a freeway can be used as a valid estimate of exposure in epidemiological studies on the effects of the traffic-related air pollutants soot and NOx in children.  相似文献   

17.
This study examined commuter’s exposure to respirable suspended particulate matters while commuting in public transportation modes. The survey was conducted between October 1999 and January 2000 in Hong Kong. A total of eight public transportation modes, that are bus, tram, public light bus, taxi, ferry, Kowloon–Canton Railway, Mass Transit Railway and Light Rail Transit, were selected in the study. They were grouped into four categories: (T1) railway transport; (T2) non-air-conditioned roadway transport; (T3) air-conditioned roadway transport and (T4) marine transport. Both PM10 and PM2.5 levels were investigated. The results indicate that the particulate level is greatly affected by the mode of transport as well as the ventilation system of the transport. The overall average PM10 concentration level in T2 (147 μg m−3) is the highest and is followed by T4 (81 μg m−3) and T3 (65 μg m−3). The PM10 level in T1 (50 μg m−3) is the lowest. Notably, the commuter exposure in tram (175 μg m−3) is the highest among all the monitored commuting modes. Commuting modes such as railway and air-conditioned vehicle are recommended as a substitute for non-air-conditioned vehicle. The PM2.5 to PM10 ratio in transports ranged from 63% to 78%. Higher PM2.5 to PM10 ratio is found in vehicles with air-conditioning system. For the double deck vehicle, higher PM10 level has resulted in the lower deck. The average upper-deck to lower-deck PM10 ratio is 0.836, 0.751 and 0.738 in air-conditioned bus, non-air-conditioned bus and non-air-conditioned tram, respectively. Typical concentration profiles in different transports are also presented.  相似文献   

18.
Abstract

A mobile exposure and air pollution measurement system was developed and used for on-freeway ultrafine particle health effects studies. A nine-passenger van was modified with a high-efficiency particulate air (HEPA) filtration system that can deliver filtered or unfiltered air to an exposure chamber inside the van. State-of-the-art instruments were used to measure concentration and size distribution of fine and ultrafine particles and the concentration of carbon monoxide (CO), black carbon (BC), particle-bound polycyclic aromatic hydrocarbons (PAHs), fine particulate matter (PM2.5) mass, and oxides of nitrogen (NOx) inside the exposure chamber. This paper presents the construction and technical details of the van and air pollutant concentrations collected in 32 2-hr runs on two major Los Angeles freeways, Interstate 405 (I-405; mostly gasoline traffic) and Interstate 710 (I-710; large proportion of heavy-duty diesel traffic). More than 97% of particles were removed when the flow through the filter box was switched from bypass mode to filter mode while the vehicle was driving on both freeways. The filtration system thus provides a great particulate matter exposure contrast while keeping gas-phase pollutant concentrations the same. Under bypass mode, average total particle number concentration observed inside the exposure chamber was around 8.4 × 104 and 1.3 × 105 particles cm-3 on the I-405 and the I-710 freeways, respectively. Bimodal size distributions were consistent and similar for both freeways with the first mode around 16–20 nm and the second mode around 50–55 nm. BC and particle-bound PAH concentrations were more than two times greater on the I-710 than on the I-405 freeway. Very weak correlations were observed between total particle number concentrations and other vehicular pollutants on the freeways.  相似文献   

19.
Little is known about particulate elemental carbon (EC) personal exposure levels, a key component of diesel exhaust, specifically in transport microenvironments. A method utilizing the optical properties of EC particles has been applied to personal exposure measurement filter samples. In a series of field studies carried out in London, UK, during 1999–2000 over 400 fine particle (PM2.5) personal exposure level measurements were taken for journeys in bicycle, bus, car and underground rail transport microenvironments, along three main fixed routes. The particulate EC contribution to the PM2.5 personal exposure was assessed indirectly by means of an optical technique and with the development and use of a size fraction specific and site-specific calibration curve. In this first EC personal exposure study of transport users geometric mean exposure levels in the summer field campaign were 11.2 μg m−3 (GSD=2.7) for cyclists, 13.6 μg m−3 (GSD=1.9) for bus passengers and 21.6 μg m−3 (GSD=2.1) for car drivers; corresponding exposure levels in the winter were 16.4 μg m−3 (GSD=1.8), 18.6 μg m−3 (GSD=2.3) and 27.3 μg m−3 (GSD=2.0), respectively. EC/PM2.5 ratios were approximately 0.5–0.6 for bicycle and bus modes and 0.7–0.8 for the car mode. EC/PM2.5 ratios for different routes ranged from approximately 0.7 for Route 1 to 0.4 for Route 3. Cyclists had the lowest exposure to EC, and car occupants the highest exposure. A large difference in exposure levels between a central high traffic density route and the other less central routes was observed. Particulate EC was a very significant proportion of the total PM2.5 personal exposure and EC personal exposure levels were considerably higher than reported fixed site monitor EC concentrations.  相似文献   

20.
ABSTRACT

Although it is much safer and more fuel-efficient to transport children to school in buses than in private vehicles, school buses in the United States still consume 822 million gal of diesel fuel annually, and school transportation costs can account for a significant portion of resource-constrained school district budgets. Additionally, children in diesel-powered school buses may be exposed to higher levels of particulates and other pollutants than children in cars. One solution to emission and fuel concerns is use of hybrid-electric school buses, which have the potential to reduce emissions and overall lifecycle costs compared with conventional diesel buses. Hybrid-electric technologies are available in the passenger vehicle market as well as the transit bus market and have a track record indicating fuel economy and emissions benefits. This paper summarizes the results of an in-use fuel economy evaluation for two plug-in hybrid school buses deployed in two different school districts in Iowa. Each school district selected a control bus with a route similar to that of the hybrid bus. Odometer readings, fuel consumption, and maintenance needs were recorded for each bus. The buses were deployed in 2008 and data were collected through May 2010. Fuel consumption was calculated for each school district. In Nevada, IA, the overall average fuel economy was 8.23 mpg for the hybrid and 6.35 mpg for the control bus. In Sigourney, IA, the overall average fuel economy was 8.94 mpg for the hybrid and 6.42 mpg for the control bus. The fuel consumption data were compared for the hybrid and control buses using a Wilcoxon signed rank test. Results indicate that fuel economy for the Nevada hybrid bus was 29.6% better than for the Nevada control bus, and fuel economy for the Sigourney hybrid bus was 39.2% higher than for the Sigourney control bus. Both differences were statistically significant.

IMPLICATIONS The results of the research presented in this paper can be readily used by school districts and policy-makers who are interested in purchasing hybrid school buses. Very little information about actual on-road fuel consumption or costs is available. Because the cost of a hybrid bus can be significantly more than the cost of a conventional bus, the information provided in this paper can be very useful for an agency to determine the costs and benefits of a hybrid bus. The information is also useful to researchers who are studying hybrid school and transit buses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号