首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Large amounts of construction materials will be needed in Europe in anticipation for capping landfills that will be closed due to the tightening up of landfill legislation. This study was conducted to assess the potential environmental impacts of using refuse derived fuel (RDF) and municipal solid waste incineration (MSWI) ashes as substitutes for natural materials in landfill cover designs. The leaching of substances from a full-scale landfill cover test area built with different fly and bottom ashes was evaluated based on laboratory tests and field monitoring. The water that drained off above the liner (drainage) and the water that percolated through the liner into the landfill (leachate) were contaminated with Cl?, nitrogen and several trace elements (e.g., As, Cu, Mo, Ni and Se). The drainage from layers containing ash will probably require pre-treatment before discharge. The leachate quality from the ash cover is expected to have a minor influence on overall landfill leachate quality because the amounts generated from the ash covers were low, <3–30 l (m2 yr)?1. Geochemical modelling indicated that precipitation of clay minerals and other secondary compounds in the ash liner was possible within 3 years after construction, which could contribute to the retention of trace elements in the liner in the long term. Hence, from an environmental view point, the placement of ashes in layers above the liner is more critical than within the liner.  相似文献   

2.
Uncontrolled leachate emissions are one of the key factors in the environmental impact of municipal solid waste (MSW) landfills. The concentration of ammonium, given the anaerobic conditions in traditional landfills, can remain significantly high for a very long period of time, as degradation does not take place and volatilisation is not significant (the pH is not high enough to considerably shift the equilibrium towards un-ionised ammonia). Recent years have witnessed a continuous enhancement of landfill technology in order to minimize uncontrolled emissions into the environment; bottom lining systems have been improved and more attention has been devoted to the study of the attenuation of the different chemicals in leachate in case of migration through the mineral barrier. Different natural materials have been considered for use as components of landfill liners in the last years and tested in order to evaluate the performance of the different alternatives. Among those materials, bentonite is often used, coupled with other materials in two different ways: in addition to in situ soil or in geocomposite clay liner (GCL). A lab-scale test was carried out in order to further investigate the influence of bentonite on the attenuation of ammonium in leachate passing through a landfill liner. Two different tests were conducted: a standardized batch test with pulverized bentonite and a batch test with compacted bentonite. The latter was proposed in order to better simulate the real conditions in a landfill liner. The two tests produced values for the partition coefficient K(d) higher than the average measured for other natural materials usually utilized as components of landfill liners. Moreover, the two tests showed similar results, thus providing a further validation of the suitability of the standard batch test with pulverized bentonite. A thorough knowledge of attenuation processes of ammonium in landfill liners is the basis for the application of risk analysis models for the evaluation of the failure of bottom liners or their components.  相似文献   

3.
A compacted soil liner (CSL) has been widely used as a single barrier layer or a part of composite barrier layer in the landfill final cover system to prevent water infiltration into solid wastes for its acceptable hydraulic permeability. This study was conducted to test whether the CSL was also effective in prohibiting landfill gas emissions. For this purpose, three different compaction methods (i.e., reduced, standard, and modified Proctor methods) were used to prepare the soil specimens, with nitrogen as gas, and with water and heptane as liquid permeants. Measured gas permeability ranged from 2.03x10(-10) to 4.96x10(-9)cm(2), which was a magnitude of two or three orders greater than hydraulic permeability (9.60x10(-13) to 1.05x10(-11)cm(2)). The difference between gas and hydraulic permeabilities can be explained by gas slippage, which makes gas more permeable, and by soil-water interaction, which impedes water flow and then makes water less permeable. This explanation was also supported by the result that a liquid permeability measured with heptane as a non-polar liquid was similar to the intrinsic gas permeability. The data demonstrate that hydraulic requirement for the CSL is not enough to control the gas emissions from a landfill.  相似文献   

4.
Geosynthetic liner systems are generally installed in landfill sites to prevent toxic leachate from escaping into the adjoining environment by utilizing their impervious characteristics. Therefore, it is important to protect the geomembrane from being damaged or destroyed during all phases of landfilling, namely landfill construction, waste tipping and landfill closure. This paper presents firstly the observed performance of a geomembrane liner from a landfill site where the geomembrane liner was installed on the slopes of a Korean landfill; and secondly the results of an inclined board laboratory test. Two types of experiments were conducted to identify the protecting effect of the overlaying geosynthetic on the geomembrane liners. At a testing landfill site, the slope consisted of three different sub-inclines and two 2-m-wide intermediate levels. The sub-inclines were each 8 m in vertical height and their angle of inclination was 1: 1.5 (vertical: horizontal). The reported observations were made for a time period of approximately 1 year, until the landfill was filled with wastes to the top of the uppermost slope. In addition, inclined board laboratory tests were carried out. During the inclined board test, a base table is inclined slowly and steadily until the block located on the base table starts to slide, when the tension and displacements of two geosynthetics, namely the geomembrane liner and protecting geotextile, are measured. In conclusion, test results showed that the down-drag force generated by waste accumulation and sliding of upper material was to a large extent dissipated through the elongation of the protecting geosynthetic overlying the geomembrane and thus was not transferred to the geomembrane. Unless the protecting geosynthetic undergoes structural failure, this stress relaxation phenomenon continues to occur so that the magnitude of tensile force to be applied on the geomembrane remains marginal.  相似文献   

5.
The self-sealing/self-healing (SS/SH) barrier concept is based on the principle that two or more parent materials placed in vertical or horizontal layers will react at their interfaces to form insoluble reaction products. These products constitute a seamless impermeable seal, which is resistant to the transmission of leachate and contaminants. A SS/SH liner formulation was developed in the laboratory and demonstrated at the Sudokwon landfill site in South Korea. Laboratory testing results indicated that a seal with a hydraulic conductivity less than 10(-9) m/s formed after two to four weeks of curing at room temperature, and the seal healed itself after it was fractured. The use of the soil from the Sudokwon landfill site instead of sand as the matrix of the parent materials in the SS/SH liner retarded the sealing and healing of the seal, but did not show an obvious effect on the overall sealing and healing capacity of the seal at early stages. The construction and installation of the field demonstration SS/SH liner were carried out in the same way as for a soil cement liner. The quality of the liner was ensured by the enforcement of quality analysis/quality control procedures during installation. A single sealed ring infiltration test was performed on the field demonstration liner 36 days after the installation was completed. The measurement of water infiltration rate indicated that the liner healed after it was fractured. However, the long-term sealing and healing capacity needs to be further investigated.  相似文献   

6.
The effect of mixing three Kentucky, U.S.A. coal slurries with soil on the transport of benzene and trichloroethylene (TCE) through a compacted landfill soil liner was investigated. Using typical values for variables, assuming no competition between contaminants, and a two to one soil-coal slurry ratio all three coal slurries were predicted to maintain the concentration of benzene emanating from a landfill liner below the maximum concentration limit (MCL) of 0.005 mg/l for at least 40 years. The concentration of TCE emanating from a landfill liner was predicted to remain below 0.001 mg/l for at least 100 years. The saturated hydraulic conductivity of a compacted silty loam soil (typical landfill soil liner material) was not found to be affected by the addition of coal slurry at a ratio of two parts soil to one part coal slurry. The results presented indicate that coal slurry amended soil will slow the movement of non-ionic organic contaminants through a landfill liner while the liner retains a low hydraulic conductivity.  相似文献   

7.
Heat generated by the biodegradation of waste and other chemical processes in a landfill can potentially affect the long-term performance of landfill liner system, in particular that of a high-density polyethylene geomembrane. In a double liner system, the difference in leachate exposure and temperature might improve the long-term performance of the secondary geomembrane compared to that of the primary geomembrane. However, in some cases, the temperature is likely to be high enough to substantially reduce the service-life of the secondary geomembrane. This study explores the possible effectiveness of using tire chips as thermal insulation between primary and secondary liners to reduce the temperature of secondary geomembranes as compared to traditional soil materials. Heat and contaminant migration analyses are performed for cases with no insulation and for cases in which a layer of soil or tire chips has been used as thermal insulation between the primary and secondary liners. The effect of insulation on prolonging the service-life of a secondary geomembrane and, consequently, on contaminant transport through a liner system is examined for the case of a volatile organic compound (dichloromethane) found in landfill leachate. The study suggests that the use of tire chips warrants consideration, however there are other practical issues that require consideration in the detailed design and construction of landfill liners. Issues such as finite service-life, low working temperature, excessive settlement, ability to generate internal heat, leaching of tire chips and limitations in performing electrical resistivity leak detection tests are identified.  相似文献   

8.
This research concentrates the design, construction and evaluation of simulated pilot scale landfill lysimeter at KUET campus, Khulna, Bangladesh. Both the aerobic and anaerobic conditions having a base liner and two different types of cap liner were simulated. After the design of a reference cell, the construction of landfill lysimeter was started in January 2008 and completed in July 2008. In all construction process locally available civil construction materials were used. The municipal solid waste (MSW) of 2800–2985 kg having the total volume of 2.80 m3 (height 1.6 m) and moisture content of 65% was deposited in each lysimeter by applying required compaction energy. In contrast, both the composition in terms of methane (CH4), carbon dioxide (CO2) and oxygen (O2) as well as the flow rate of landfill gas (LFG) generated from MSW in landfill lysimeter were measured and varied significantly in relation to the variation of lysimeter operational condition. Moreover, anaerobic lysimeter-C shows the highest composition of LFG in compare to the anaerobic lysimeter-B due to the providing of lower compaction of cap liner in anaerobic lysimeter-C. Here, it is interesting to note that in absence of compacted clay liner (CCL) and hence percolation of rainwater that facilitates rapid degradation of MSW in aerobic lysimeter-A has resulted in the highest settlement than that of anaerobic landfill lysimeter-B and C. Moreover, in case of anaerobic lysimeter-B and C, the leachate generation was lower than that of aerobic lysimeter-A due to the providing of cap liner in anaerobic lysimeter-B and C, played an important role to reduce the percolation of rainwater. The study also reveals that the leachate pollution index (LPI) has decreased in relation to the increasing of elapsed period as well as the LPI for collection system of aerobic lysimeter-A was higher than that of the collection system of anaerobic lysimeter-B and C. Finally, it can be depicted that LPI for lysimeter was significantly high and proper treatment will be necessary before discharging the lysimeter leachate into the water bodies.  相似文献   

9.
 Some minimum design requirements for landfill liner systems were compared, and the performance of several Japanese liner systems was investigated by two-dimensional (2D) contaminant transport analysis. We demonstrate that (1) the performance of each system specified by the Japanese Ministry of Health and Welfare (at present the Ministry of Health, Labor, and Welfare) varies, (2) the adsorption characteristics of the mineral barrier has a significant effect on the contaminant transport process, and (3) a geomembrane layer in the barrier system is very efficient in reducing the peak concentration of contaminants in the groundwater beneath a landfill even if the geomembrane has a number of defects. Under the conditions considered, the analysis results show that a liner system without a geomembrane layer should be avoided. Received: July 4, 2001 / Accepted: March 26, 2002  相似文献   

10.
The objective of the study was to develop a low cost and environmentally friendly liner system for a landfill bioreactor to harness energy from waste. The landfill bioreactor test cell was constructed and evaluated for performance under dry tropical conditions of Sri Lanka. The research was carried out from March 2009 to September 2010. The clay-waste polyethylene-clay composite liner system was developed and permeability was tested. The permeability values of the liner under both saturated and unsaturated conditions at the high estimated hydraulic head of 86.2 cm were in between 6.3 × 10−8 and 2.6 × 10−8 cm/s. The permeability of the liner under waste filled condition varied between 2.17 × 10−9 and 8.15 × 10−9 cm/s, which satisfies the standard permeability value. Thus, the results were below the minimum requirement at very high estimated leachate head. After loading the test cell, leachate and permeate characteristics were analyzed for 273 days, from January 2010 to September 2010. The study showed the relationships among various parameters including pH, electrical permeability, chemical oxygen demand, biological oxygen demand, ammonia, nitrate, phosphate, total solids, volatile solids, total suspended solids and volatile suspended solids. The results of the analysis indicated that there are significant differences in the values of leachate and permeate parameters. The permeate parameters had values very much lower than those of leachate. It reveals that the clay-waste polyethylene-clay composite liner system reduced the concentration of these parameters when the leachate passed through the liner. The biofilm formed in waste polyethylene within the liner may have degraded most of organic materials found in the leachate when it passed through the liner. Therefore, the clay-waste polyethylene-clay composite liner system can be applied for full scale landfill bioreactors, particularly for Asian developing countries, due to better performance and more environmentally friendly characteristics.  相似文献   

11.
A new computer-based life-cycle assessment model (EASEWASTE) has been developed to evaluate resource and environmental consequences of solid waste management systems. This paper describes the landfilling sub-model used in the life-cycle assessment program EASEWASTE, and examines some of the implications of this sub-model. All quantities and concentrations of leachate and landfill gas can be modified by the user in order to bring them in agreement with the actual landfill that is assessed by the model. All emissions, except the generation of landfill gas, are process specific. The landfill gas generation is calculated on the basis of organic matter in the landfilled waste. A landfill assessment example is provided. For this example, the normalised environmental effects of landfill gas on global warming and photochemical smog are much greater than the environmental effects for landfill leachate or for landfill construction. A sensitivity analysis for this example indicates that the overall environmental impact is sensitive to the gas collection efficiency and the use of the gas, but not to the amount of leachate generated, or the amount of soil or liner material used in construction. The landfill model can be used for evaluating different technologies with different liners, gas and leachate collection efficiencies, and to compare the environmental consequences of landfilling with alternative waste treatment options such as incineration or anaerobic digestion.  相似文献   

12.
A review of aqueous-phase VOC transport in modern landfill liners   总被引:3,自引:0,他引:3  
Leachates from municipal solid waste (MSW) and hazardous waste landfills contain a wide range of volatile organic compounds (VOCs) in addition to inorganic compounds. VOCs have been shown to migrate and contaminate the surrounding environment and impair the use of groundwater. Therefore, the effectiveness of modern landfill liner systems to minimize migration of VOCs is of concern. Most modern landfills employ a composite liner consisting of a geomembrane overlying a compacted clay liner or a geosynthetic clay liner. The geomembrane is often believed to be the primary barrier to contaminant transport. However, for VOCs, the clay component usually controls the rate of transport since VOCs are shown to diffuse through geomembrane at appreciable rates. Additionally, analyses have shown that transport of volatile organic compounds (VOCs) generally is more critical than transport of inorganic compounds (e.g., toxic heavy metals), even though VOCs are often found at lower concentrations in leachates. Therefore, the effectiveness of modern landfill liner systems to minimize migration of VOCs and transport of VOCs through clay liners and modeling of transport through composite liners merit scrutiny. This paper presents a review of recent research by the author and others on these topics. A systematic and comprehensive approach to determine mass transport parameters for transport of VOCs in liquid phase through compacted clay liners, geosynthetic clay liners (GCLs), and geomembranes has enabled to develop realistic models to predict mass flux of VOCs through modern composite liners and provide a quantitative basis to evaluate potential for transport of dissolved VOCs and the equivalency of different composite liners.  相似文献   

13.
A field-scale soil liner was constructed to test whether compacted soil barriers in cover and liner systems could be built to meet the U.S. EPA saturated hydraulic conductivity requirement (⩽ 1 × 10−7 cm s−1). The 8 × 15 × 0.9 m liner was constructed in 15 cm compacted lifts using a 20,037 kg pad-foot compactor and standard engineering practices. Water infiltration into the liner has been monitored for one year. Monitoring will continue until water break through at the base of the liner occurs. Estimated saturated hydraulic conductivities were 2.5 × 10−9, 4.0 × 10−8, and 5.0 × 10−8 cm s−1 based on measurements of water infiltration into the liner by large- and small-ring infiltrometers and a water balance analysis, respectively.Also investigated in this research was the variability of the liner's hydraulic properties and estimates of the transit times for water and tracers. Small variances exhibited by small-ring flux data suggested that the liner was homogeneous with respect to infiltration fluxes. The predictions of water and tracer breakthrough at the base of the liner ranged from 2.4–12.6 y, depending on the method of calculation and assumptions made. The liner appeared to be saturated to a depth between 18 and 33 cm at the end of the first year of monitoring. Transit time calculations cannot be verified yet, since breakthrough has not occurred. The work conducted so far indicates that compacted soil barriers can be constructed to meet the saturated hydraulic conductivity requirement established by the U.S. EPA.  相似文献   

14.
The characteristics of municipal solid waste (MSW) play a key role in many aspects of waste disposal facilities and landfills. Because most of a landfill is made up of MSW, the overall stability of the landfill slopes are governed by the strength parameters and physical properties of the MSW. These parameters are also important in interactions involving the waste body and the landfill structures: cover liner, leachate and gas collection systems. On the other hand, the composition of the waste, which affects the geotechnical behavior of the MSW, is dependent on a variety of factors such as climate, disposal technology, the culture and habits of the local community. It is therefore essential that the design and stability evaluations of landfills in each region be performed based on the local conditions and the geotechnical characteristic of the MSW. The Bandeirantes Landfill, BL, in São Paulo and the Metropolitan Center Landfill, MCL, in Salvador, are among the biggest landfills in Brazil. These two disposal facilities have been used for the development of research involving waste mechanics in recent years. Considerable work has been made in the laboratory and in the field to evaluate parameters such as water and organic contents, composition, permeability, and shear strength. This paper shows and analyzes the results of tests performed on these two landfills. The authors believe that these results could be a good reference for certain aspects and geotechnical properties of MSW materials in countries with similar conditions.  相似文献   

15.
This study aims to characterize the leachate and to investigate the tropical climatic influence on leachate characteristics of lysimeter studies under different seasonal variations at KUET campus, Bangladesh. Three different situations of landfill were considered here as well as both the open dump lysimeter-A having a base liner and sanitary landfill lysimeter-B and C at two different types of cap liner were simulated. The leachate characteristics, leachate generation and climatic influence parameter had been continually monitored since June 2008 to May 2010, these periods cover both the dry and rainy season. The leachate generation had followed the rainfall pattern and the open dump lysimeter-A without top cover was recorded to have highest leachate generation. Moreover, the open dump lysimeter-A had lower total kjeldahl nitrogen (TKN), ammonia nitrogen (NH(4)-N) and TKN load, while both the COD concentration and load was higher compared with sanitary landfill lysimeter-B and C. In addition, sanitary landfill lysimeter-B, not only had lowest leachate generation, but also produces reasonable low COD concentration and load compared with open dump lysimeter-A. Result reveals that lysimeter operational mode had direct effect on leachate quality. Finally, it can be concluded that the knowledge of leachate quality will be useful in planning and providing remedial measures of proper liner system in sanitary landfill design and leachate treatment.  相似文献   

16.
Contaminant transport through the clay liner and the underIying secondary leachate drain layer (SLDL) in landfills was studied through a laboratory test, and analysis method on the transport of K+ in a two-layer soil system. The soils used for this study were Ariake clay and the underlying layer, Shirasu soil from the Kyushu region of Japan, representing the clay liner material and SLDL material, respectively. The effective diffusion coefficients (De) of the selected target chemical species, potassium (K+) for the Ariake clay and Shirasu soil were back-calculated using a computer program, and it was found that values of De derived from this study were consistent with those previously published. The hypothesis that the mechanical dispersion process can be negligible has been proved to be reasonable based on both the observation that the predicted values fit the experimental data and the analyses of two dimensionless parameters. Parametric analysis showed the transport of K+ through the soils is controlled by advection-diffusion rather than diffusion only, whereas at low Darcy velocity (i.e. < or = 10(-9) m s(-1)), transport of K+ would be controlled by diffusion. The test results and parametric analysis may be applied in design of landfill liners and SLDLs, particularly in coastal areas.  相似文献   

17.
Final landfill covers are highly engineered to prevent methane release into the atmosphere. However, methane production begins soon after waste placement and is an unaddressed source of emissions. The methane oxidation capacity of methanotrophs embedded in a “bio-tarp” was investigated as a means to mitigate methane release from open landfill cells. The bio-tarp would also serve as an alternative daily cover during routine landfill operation.Evaluations of nine synthetic geotextiles identified two that would likely be suitable bio-tarp components. Pilot tarp prototypes were tested in continuous flow systems simulating landfill gas conditions. Multilayered bio-tarp prototypes consisting of alternating layers of the two geotextiles were found to remove 16% of the methane flowing through the bio-tarp. The addition of landfill cover soil, compost, or shale amendments to the bio-tarp increased the methane removal up to 32%. With evidence of methane removal in a laboratory bioreactor, prototypes were evaluated at a local landfill using flux chambers installed atop intermediate cover at a landfill. The multilayered bio-tarp and amended bio-tarp configurations were all found to decrease landfill methane flux; however, the performance efficacy of bio-tarps was not significantly different from controls without methanotrophs. Because highly variable methane fluxes at the field site likely confounded the test results, repeat field testing is recommended under more controlled flux conditions.  相似文献   

18.
A number of LCA-based studies have reported on the environmental performance of landfilling of mixed waste, but little is known about the relative contributions of individual waste fractions to the overall impact potentials estimated for the mixed waste. In this paper, an empirical model has been used to estimate the emissions to the environment from landfilling of individual waste fractions. By means of the LCA-model EASEWASTE, the emissions estimated have been used to quantify how much of the overall impact potential for each impact category is to be attributed to the individual waste fractions. Impact potentials are estimated for 1 tonne of mixed waste disposed off in a conventional landfill with bottom liner, leachate collection and treatment and gas collection and utilization for electricity generation. All the environmental aspects are accounted for 100 years after disposal and several impact categories have been considered, including standard categories, toxicity-related categories and groundwater contamination.Amongst the standard and toxicity-related categories, the highest potential impact is estimated for human toxicity via soil (HTs; 12 mPE/tonne). This is mostly caused by leaching of heavy metals from ashes (e.g. residues from roads cleaning and vacuum cleaning bags), batteries, paper and metals. On the other hand, substantial net environmental savings are estimated for the categories Global Warming (GW; ?31 mPE/tonne) and Eco-Toxicity in water chronic (ETwc; ?53 mPE/tonne). These savings are mostly determined by the waste fractions characterized by a high content of biogenic carbon (paper, organics, other combustible waste). These savings are due to emissions from energy generation avoided by landfill gas utilization, and by the storage of biogenic carbon in the landfill due to incomplete waste degradation.  相似文献   

19.
The observed temperatures in different landfills are used to establish a number of idealized time–temperature histories for geomembrane liners in municipal solid waste (MSW) landfills. These are then used for estimating the service life of different HDPE geomembranes. The predicted antioxidant depletion times (Stage I) are between 7 and 750 years with the large variation depending on the specific HDPE geomembrane product, exposure conditions, and most importantly, the magnitude and duration of the peak liner temperature. The higher end of the range corresponds to data from geomembranes aged in simulated landfill liner tests and a maximum liner temperature of 37 °C. The lower end of the range corresponds to a testing condition where geomembranes were immersed in a synthetic leachate and a maximum liner temperature of 60 °C. The total service life of the geomembranes was estimated to be between 20 and 3300 years depending on the time–temperature history examined. The range illustrates the important role that time–temperature history could play in terms of geomembrane service life. The need for long-term monitoring of landfill liner temperature and for geomembrane ageing studies that will provide improved data for assessing the likely long-term performance of geomembranes in MSW landfills are highlighted.  相似文献   

20.
A large-scale field experiment has been carried out at the Coastal Park landfill which serves the City of Cape Town, South Africa. The landfill is unlined, and the City Council was under pressure from the central Government to cap and close the existing landfill and to establish an extension to the landfill with a lining to prevent the escape of leachate into the ground water. Measuring cells, installed to measure the rate of leachate flow from the landfill had shown that over a period of 9 years, from 1987 to 1995, leachate flow had averaged only 2% of rainfall. It therefore appeared possible, by increasing the moisture absorption capacity of the landfill, i.e., by increasing its height, to stop the leachate flow completely. If this could be achieved, there would be no need for a lining, and the raising would considerably extend the life of the landfill.The paper describes the experiment and its results, including the effects of the raising on leachate flow, settlement, leachate quality and the potential for polluting ground water, and the landfill’s water balance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号