首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 119 毫秒
1.
Reverse osmosis system with the disc-tube module (DT-RO) was applied to treat landfill leachate on full scale at the Changshengqiao Sanitary Landfill, Chongqing City, China. In the first six-mouth operation phase, the treatment performance of DT-RO system had been excellent and stable. The removal rate of chemical oxygen demand (COD), total organic carbon (TOC), electrical conductivity (EC), and ammonia nitrogen (NH3-N) reached 99.2–99.7%, 99.2%, 99.6%, and over 98%, respectively. The rejection of Ca2+, Ba2+, and Mg2+ was over 99.9%, respectively. Suspended solid (SS) was not detected in product water. Effective methods had been adopted to control membrane fouling, of which chemical cleaning is of utmost importance to guarantee the long smooth operation of the DT-RO system. The DT-RO system is cleaned in turns with Cleaner A and Cleaner C. At present, the 1st stage cleaning cycle by Cleaner A and Cleaner C is conducted every 100 and 500 h, respectively, depending on raw the water quality.  相似文献   

2.
三峡库区填埋场和焚烧厂渗滤液水质季节性差异   总被引:5,自引:3,他引:2  
分析了重庆长生桥垃圾填埋场和同兴焚烧厂渗滤液在常规水质和溶解性有机质组成结构方面的季节性差异. 结果表明,填埋场渗滤液在夏季的ρ(CODCr), ρ(TOC), ρ(BOD5),ρ(BOD5)/ρ(CODCr)和ρ(VFA)均高于其他季节,相应指标在冬季最低,但ρ(NH3-N)和 pH的季节性差异不明显. 填埋场渗滤液中DOM组成结构的季节性差异较大,表现在冬季渗滤液中HA所占比例最高,为16.1%,而春、夏季分别为6.6%和8.1%;冬季渗滤液中HyI所占比例最低,为32.7%,其他季节为41.9%~43.5%;ρ(FA)的季节性差异相对较小. 填埋场中ρ(FA)/ρ(HA)的季节性差异较大,夏季较高,冬季较小. 焚烧厂渗滤液的常规水质,DOM的构成及ρ(FA)/ρ(HA)的季节性差异均很小.   相似文献   

3.
韩智勇  刘丹  李启彬  陈馨 《环境科学》2012,33(11):3873-3880
为了减少生物反应器填埋场投资和运行费用,实现填埋场的快速稳定化,将厌氧型生物反应器填埋场(ANBL)和准好氧矿化垃圾生物反应床(SAARB)串联,组成新型的厌氧-准好氧联合型生物反应器填埋场(AN-SABL).通过研究AN-SABL渗滤液水质水量变化规律,以期为其渗滤液的管理和处理提供理论依据.实验表明,AN-SABL具有较好的渗滤液削减作用,最高削减量可达到771 g·kg-1;而且AN-SABL渗滤液水质变化具有明显的阶段性特征,渗滤液中硝酸盐(包括亚硝酸盐)浓度和氨氮浓度分别受Eh值和pH值影响明显.AN-SABL能够有效去除渗滤液中的有机物,实验结束时,AN-SABL2号和AN-SABL3号渗滤液COD的去除率分别达到了98.49%和97.98%,二者的COD浓度仅为ANBL1号COD浓度的14.5%、21.1%;同时,AN-SABL有较好的脱氮作用,AN-SABL2号和AN-SABL3号渗滤液中氨氮浓度分别从最高值1 452 mg·L-1、1 409 mg·L-1下降至525 mg·L-1、459 mg·L-1,只有ANBL1号氨氮浓度的36.5%和31.9%.SAARB单元的脱氮除碳效果受TOC/TC值的影响明显,当渗滤液中TOC/TC下降到0.2左右后,SAARB单元对COD和TN的去除率分别从95%和93%以上降到了35.25%~69.56%和64.53%~77.45%之间.  相似文献   

4.
Fenton氧化法预处理并提高垃圾渗沥液可生化性的研究   总被引:2,自引:2,他引:0  
采用Fenton氧化法对垃圾渗沥液进行预处理.基于响应面法研究了Fenton氧化法对垃圾渗沥液的处理效能,考察了初始pH值、H_2O_2投加量和[H_2O_2]/[Fe~(2+)]摩尔比对TOC去除率的影响,并拟合了TOC去除率与三因素之间的回归方程.同时,通过三维荧光和凝胶色谱比较了Fenton处理前后渗沥液的可生化性.结果发现,渗沥液中类富里酸等难降解有机物得到有效去除,B/C比从0.1左右升至0.25.研究表明,Fenton氧化法可有效改善垃圾渗沥液的可生化性,为后续生物处理创造了条件.  相似文献   

5.
生活垃圾堆肥渗滤液污染物组成与演化规律研究   总被引:6,自引:4,他引:2  
为阐明堆肥渗滤液的组成和演化规律,寻找合适的处理技术,研究了某堆肥厂不同堆肥时期渗滤液中无机阴离子、氨氮、重金属及有机物等的组成和演化特性.结果显示,随着堆肥的进行,EC及F-、Cl-、SO24-、NH4+-N的浓度呈下降趋势,而NO2--N、NO3--N及Org-N的含量与渗滤液的氧化还原氛围有关;渗滤液中重金属Pb、Cd、Cu、Zn及类金属As随堆肥进行浓度呈下降趋势,而重金属Cr、Ni、Fe、Mn随堆肥进行浓度上升;堆肥渗滤液有机物主要为类蛋白物质,但也含有类腐殖质物质,适合先生化后物化处理依次去除;堆肥过程中类蛋白物质相对含量先增加后减少,而类腐殖质相对含量先减少后增加.堆肥渗滤液盐分和重金属含量较高,不宜堆肥回流利用,应先生化后物化处理达标后排放.  相似文献   

6.
填埋垃圾浸提液与地下水污染物组成差异及成因   总被引:5,自引:4,他引:1  
为揭示垃圾渗滤液污染地下水特征,采用常规分析、三维荧光光谱和多元统计分析,研究了某简易填埋场垃圾浸提液与地下水中无机盐、有机物及重金属的分布特征及成因.结果表明,填埋场垃圾异质性强,浸提液中NH+4-N浓度高,而Cl-、SO2-4、溶解性有机物(DOM)、重金属含量低,强还原氛围导致硝化过程受阻,NO-3-N、NO-2-N含量低,浸提液中Cu主要结合在DOM上,而Ba、Cd、Cr、Fe、Mn、Ni、Zn及As主要结合在疏水性有机物上.除填埋场所在点地下水外,其余点地下水污染物来源相似,其中的DOM以微生物来源为主;与垃圾浸提液中污染物分布特征相反,地下水中NH+4-N含量低而Cl-、SO2-4、DOM、NO-3-N、NO-2-N含量高,Cu、Ba、Cd、Fe、Mn及Ni的分布与DOM有关,主要结合在荧光有机物上.研究结果显示,基于地下水中污染物组成差异,采用聚类分析方法可识别出地下水受渗滤液污染点.  相似文献   

7.
微波催化氧化法预处理垃圾渗滤液的研究   总被引:6,自引:0,他引:6       下载免费PDF全文
采用微波-活性炭-Fenton催化氧化预处理垃圾渗滤液,研究了不同因素对垃圾渗滤液处理效果的影响.结果表明,COD和氨氮去除率随活性炭用量、微波辐射时间和微波功率增加而增加;随Fe2+用量和H2O2用量增加,COD和氨氮去除率先增加而后下降;随pH值增加,氨氮去除率显著增加,COD去除率变化不明显.在微波功率为300W,pH值为8,活性炭9g/L,Fe2+用量为0.02mol/L,H2O2用量为7mL/L,辐射时间6min条件下,垃圾渗滤液中COD和氨氮去除率分别达到68.22%和78.08%,SS去除率达到78.55%,浑浊度去除率达到99.02%,颜色由黑褐色去除为接近无色,BOD5/COD由0.21提高到0.45;研究比较了不同处理对垃圾渗滤液的处理效果.结果显示,微波催化氧化对垃圾渗滤液中COD和氨氮去除率明显高于其他处理.  相似文献   

8.
响应面法分析卫生填埋渗滤液的Fenton处理过程   总被引:4,自引:0,他引:4  
利用响应面法研究了Fenton试剂处理卫生填埋渗滤液过程中诸因素对COD去除率的影响,如渗滤液中高分子量有机物(HMWOM)与低分子量有机物(LMWOM)的TOC比例、LMWOM浓度以及双氧水和亚铁离子的摩尔比(H2O2/Fe2+).其中HMWOM/LMWOM值、LMWOM浓度和H2O2/Fe2+摩尔比值的高、低水平分别为14~38,975~3000 mg/L,1.75~4.00.由实验数据得到了1个2次响应曲面模型,该模型显示COD的去除率随着HMWOM/LMWOM值的增加而增加,但随着LMWOM浓度的增加而降低.Fenton试剂处理卫生填埋渗滤液存在着一个最佳的H2O2/Fe2+摩尔比值,COD去除率在该点能达到最高.  相似文献   

9.
腐蚀电池-Fenton工艺用于垃圾渗滤液的预处理研究   总被引:8,自引:1,他引:8  
采用铁屑和颗粒活性炭通过原电池反应产生的Fe2 离子取代FeSO4组成腐蚀电池-Fenton工艺,采用该工艺对垃圾渗滤液进行预处理.结果表明,最佳运行条件为pH值为2、H2O2投加量为理论投加量的50%、铁屑投量为30 g(500 mL渗滤液中)、Fe/C质量比为2.5、反应时间为1 h、絮凝pH值为7,其COD去除率可达到60%(其中活性炭吸附占19%),TOC去除率可达47%(其中活性碳吸附占13%),BOD5/COD值从原水的0 35提高到出水的0.69;而传统Fenton工艺在H2O2/Fe2 比值等于5、其它条件与腐蚀电池-Fenton工艺相同的条件下,COD去除率为26%,TOC去除率为19%,BOD5/COD比值从原水的0.43提高到0.69.将腐蚀电池-Fenton工艺用于垃圾渗滤液的预处理,在有机物去除率和提高可生化性方面效果均明显优于传统Fenton工艺.  相似文献   

10.
The removal of biological nutrient from mature landfill leachate with a high nitrogen load by an internal circulation upflow sludge blanket (ICUSB) reactor was studied. The reactor is a set of anaerobic-anoxic-aerobic (A^2/O) bioreactors, developed on the basis of an expended granular sludge blanket (EGSB), granular sequencing batch reactor (GSBR) and intermittent cycle extended aeration system (ICEAS). Leachate was subjected to stripping by agitation process and poly ferric sulfate coagulation as a pretreatment process, in order to reduce both ammonia toxicity to microorganisms and the organic contents. The reactor was operated under three different operating systems, consisting of recycling sludge with air (A^2/O), recycling sludge without air (low oxygen) and a combination of both (A^2/O and low oxygen). The lowest effluent nutrient levels were realised by the combined system of A^2/O and low oxygen, which resulted in effluent of chemical oxygen demand (COD), NH3-N and biological oxygen demand (BOD5) concentrations of 98.20, 13.50 and 22.50 mg/L. The optimal operating conditions for the efficient removal of biological nutrient using the ICUSB reactor were examined to evaluate the influence of the parameters on its performance. The results showed that average removal efflciencies of COD and NH3- N of 96.49% and 99.39%, respectively were achieved under the condition of a hydraulic retention time of 12 hr, including 4 hr of pumping air into the reactor, with dissolved oxygen at an rate of 4 mg/L and an upflow velocity 2 m/hr. These combined processes were successfully employed and effectively decreased pollutant loading.  相似文献   

11.
王东  庞之鹏  沈斐  王硕  李激 《环境科学学报》2017,37(12):4653-4661
垃圾渗滤液经预处理后与城市污水混合进行生物处理是较为有效的方法,但垃圾渗滤液中含大量难降解有机物,严重影响了城镇污水处理厂出水COD.因此,需强化垃圾渗滤液预处理过程,使其适用于生物处理.本研究采用活性焦吸附某垃圾焚烧发电厂垃圾渗滤液,发现活性焦对垃圾渗滤液中COD、色度、恶臭、TOC、TN等均具有良好的处理效果.通过对吸附性能的影响因素研究发现,活性焦种类、投加量、p H和吸附时间均会影响吸附效果,最佳活性焦投加量为20 g·L~(-1),酸性条件更有利于吸附,渗滤液中COD的去除主要发生在吸附过程的前1 h.活性焦吸附可提高垃圾渗滤液的可生化性,主要吸附垃圾渗滤液中难降解芳香族大分子有机物,其中,对溶解性有机物中疏水性有机酸组分的吸附效果最佳,使其出水适用于生物处理,从而保证污水处理厂COD可以稳定达标排放.  相似文献   

12.
渗滤液与城市污水合并处理过程的有机物去除特征   总被引:11,自引:0,他引:11  
以上海老港垃圾填埋场调蓄池的渗滤液,及其经厌氧甲烷化垃圾填埋柱循环回灌处理后的出水和其再经过混凝处理后的出水等3种不同处理水平的渗滤液为研究对象,分别以不同的比例与城市污水混合,采用好氧活性污泥法合并进行处理,对进出水的COD、UV254吸光度和溶解性有机物的分子量分布及污泥的脱氢酶活性进行了测定分析.结果表明:当渗滤液混合比例小于10%时,出水的COD和UV254吸光度随混合比例线性升高,污泥的活性相应线性降低;而当混合比例大于20%时.污泥活性阶跃降低,出水COD和UV254吸光度的升高超出线性范围.渗滤液混合比例为20%与比例为5%的混合污水相比.分子量1k~4k的溶解性有机物去除率显降低.渗滤液与城市污水合并处理的混合比例大于10%时,微生物的有机物降解能力会受到严重损害,且常规的渗滤液生物和物化预处理不能减轻此种损害.  相似文献   

13.
回灌+铁促电化学氧化工艺处理垃圾渗滤液研究   总被引:3,自引:0,他引:3  
垃圾渗滤液是一种高有机物浓度,高NH3-N浓度,多组分难处理的污水。文章在现有的理论和实践基础上论证了矿化垃圾回灌+铁促电解工艺,处理垃圾渗滤液的可行性,并进行了初步试验。试验结果表明该工艺可以有效地去除渗滤液中的COD、NH3-N和色度,是具有较大研究价值的渗滤液处理工艺。  相似文献   

14.
广州垃圾填埋渗滤液中有机污染物的去除效果   总被引:16,自引:2,他引:14  
周少奇  杨志泉 《环境科学》2005,26(3):186-191
采用同时好氧厌氧生物反应器处理广州市大田山垃圾填埋渗滤液,平均出水浓度CODCr为131mg·L-1,氨氮为7mg·L-1,达到了同类废水的国家二级排放标准.同时选择GC-MS联用仪对垃圾渗滤液中的有机物进行测定,测得有机污染物87种,其中16种有机污染物被列入美国EPA环境优先控制污染物,31种有机物被完全去除,14种有机物去除率可达80%以上,25种有机物去除率达50%以上.  相似文献   

15.
电解氧化法预处理垃圾渗滤液   总被引:23,自引:2,他引:21       下载免费PDF全文
采用连续式电解槽对垃圾渗滤液进行预处理研究.考察不同的电流密度、进水pH值、Cl-质量浓度等对电解效果的影响,从而确定了最佳操作条件.在最佳条件下,比较研究电解装置对3种不同来源的垃圾渗滤液各项指标的去除效果.结果表明,连续式电解法对中等COD质量浓度的垃圾渗滤液(COD质量浓度为2 000~10 000 mg/L)有较好的处理效果,可有效去除废水中的COD,氨氮和重金属,且对难降解的污染物(如苯胺、苯酚等)有良好的去除作用.该法提高了水质的可生化性,强化了后续生化处理,为中试及工业化工程设计应用提供了参考.   相似文献   

16.
Landfilling municipal solid waste incineration (MSWI) residue alkalizes the waste layer, causing a subsequent decrease in microbial activity and a delay in the decomposition of organic matter. In this study, efficiencies of neutralization of the leachate and organic matter decomposition in the waste layer in a column filled with MSWI residue using aeration and compost addition were evaluated.Total organic carbon (TOC) reduction in the waste layer is large at high oxygen flow rate (OFR). To effectively accelerate TOC reduction in the waste layer to which compost was added, a high OFR exceeding that by natural ventilation was required. At day 65, the pH of the leachate when OFR was above 102mol-O2/(day·m3) was lower than that when OFR was below 101mol-O2/(day·m3). At the same OFR, the pH of waste sample was lower than that of waste sample with compost. Although leachate neutralization could be affected by compost addition, TOC reduction in the waste layer became rather small. It is possible that humic substances in compost prevent the decomposition of TOC in MSWI residue.  相似文献   

17.
Microwave (MW) hybrid processes are able to disrupt the flocculent structure of complex waste activated sludge, and help promote the recovery of phosphorus as struvite. In this study, to optimize struvite yield, (1) the characteristics of matter released in MW-hybrid treatments were compared, including MW, MW-acid, MW-alkali, MW-H2O2, and MW-H2O2-alkali. The results showed that selective release of carbon, nitrogen, phosphorus, Ca2 +, and Mg2 + achieved by sludge pretreatment using MW-hybrid processes. MW-H2O2 is the recommended sludge pretreatment process for phosphorus recovery in the form of struvite. The ratio of Mg2 +:NH4+-N:PO43 −-P was 1.2:2.9:1 in the supernatant. (2) To clarify the effects of organic matter on struvite recovery, the composition and molecular weight distribution of organic matters were analyzed. Low molecular weight COD was found to facilitate the removal rate of NH4+-N and PO43-P via crystallization, and the amorphous struvite crystals (< 1 kDa) from the filtered solutions had high purity. Therefore, the present study reveals the necessity of taking into consideration the interference effect of high molecular weight organic matters during struvite crystallization from sewage sludge.  相似文献   

18.
电催化系统-电生物炭接触氧化床处理垃圾渗滤液   总被引:17,自引:1,他引:17       下载免费PDF全文
 提出了电催化系统(ECS)组合电生物炭接触氧化床(EBACOR)来处理垃圾渗滤液的方法.结果表明,ECS-EBACOR法诸多的影响因素中,对处理效率影响最大的是ECS的电活性催化填料组分.GC/MS分析结果表明,垃圾渗滤液中的64种有毒有机污染物经ECS处理后,大部分已被矿化成CO2、H2O或降解为小分子有机物.ECS-EBACOR现场运行试验结果还表明,当垃圾渗滤液废水中的COD和NH3-N浓度分别在3000~5000mg/L以及1100~1780mg/L范围时,COD和NHs3-N去除率均可超过90%.  相似文献   

19.
针对垃圾渗滤液生化尾水中仍含有较高浓度的难生物降解COD、NH4+-N和NO2--N,无法满足现行排放标准的问题,采用基于硫酸根自由基的高级氧化技术(SR-AOP)对生化尾水进行深度处理.考察了pH值、温度、FeSO4和过硫酸钠浓度对TOC和TN去除效果的单独作用及交互作用.结果表明,影响因子对于处理效果的贡献排序为:pH值>温度>过硫酸钠浓度,各因素对TOC的去除有显著性影响,而对TN的去除没有显著性影响.各因素的复合效应为:TN去除效果影响:温度+过硫酸钠浓度>pH+过硫酸钠浓度>温度+pH, TOC去除效果影响:温度+pH>pH+过硫酸钠浓度>温度+过硫酸钠浓度.实验最终确定SR-AOP的最佳条件为:pH=5,温度为30℃,过硫酸钠浓度为0.5g/L,催化剂FeSO4剂量为3.8g/L,该条件下TOC去除率为35.5%,TN去除率为16.9%,同时可以显著提高出水BOD5/COD.因此,通过SR-AOP深度处理可以去除生化处理尾水大部分COD和TN,并大幅提高B/C比,为后续与适当的生化处理工艺组合进行达标处理奠定了良好的基础.  相似文献   

20.
微波/活性炭强化过硫酸盐氧化处理垃圾渗滤液研究   总被引:2,自引:0,他引:2       下载免费PDF全文
采用微波(MW)-活性炭(AC)强化过硫酸盐(PS)氧化处理垃圾渗滤液,研究不同因素对垃圾渗滤液处理的影响,比较不同组合工艺对渗滤液处理的效果及活性炭的多次使用情况.结果表明,COD和氨氮(NH4+-N)的去除率随着AC用量、PS用量(S2O82-:12COD0)、MW功率和辐射时间的增加而增大,pH值对COD的去除影响不明显, NH4+-N在碱性条件下得到更理想的去除效果;在活性炭用量为10g/L,PS用量为S2O82-:12COD0=1.2,pH=9,MW功率和辐射时间分别为500W和10min时,垃圾渗滤液中的COD和NH4+-N去除率分别为78.2%和67.2%,BOD5/COD由0.17增至0.38;不同工艺对垃圾渗滤液处理效果显示,MW-AC-PS工艺对垃圾渗滤液中COD和氨氮去除率明显高于其他处理,且MW、AC和PS之间存在协同效应,MW热效应显著;活性炭四次实验后,COD和NH4+-N的去除率分别为61.2%和46.1%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号