首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Three methods (membrane filtration, multiple tube fermentation, and chromogenic substrate technology kits manufactured by IDEXX Laboratories, Inc.) are routinely used to measure indicator bacteria for beach water quality. To assess comparability of these methods, quantify within-laboratory variability for each method, and place that variability into context of variability among laboratories using the same method, 22 southern California laboratories participated in a series of intercalibration exercises. Each laboratory processed three to five replicates from thirteen samples, with total coliforms, fecal coliforms or enterococci measured depending on the sample. Results were generally comparable among methods, though membrane filtration appeared to underestimate the other two methods for fecal coliforms, possibly due to clumping. Variability was greatest for the multiple tube fermentation method. For all three methods, within laboratory variability was greater than among laboratories variability.  相似文献   

2.
Marine sediment toxicity tests are widely applied in monitoring programs, yet relatively little is known about the comparability of data from different laboratories. The need for comparability information is increased in cooperative monitoring programs, where multiple laboratories (often with variable skill levels) perform toxicity tests. An interlaboratory comparison exercise was conducted among seven laboratories in order to document the comparability of sediment toxicity measurements during the Bight'98 regional sediment survey in southern California. Sediments from four stations in Los Angeles and Long Beach Harbors were tested using a 10-day survival test of the amphipod Eohaustorius estuarius. All laboratories successfully performed the sediment test and associated reference toxicant test. Statistically significant differences were found in mean amphipod survival rates among some laboratories for the field-collected sediments, but there was little evidence of a consistent bias among laboratories. Although the reference toxicant test indicated a five-fold variation in test sensitivity among laboratories, these results were not accurate predictors of interlaboratory performance for the sediment tests. The laboratories demonstrated excellent concordance (Kendall's W = 0.91) in ranking the field-collected sediments by toxicity. Agreement on classifying the sediments into categories (nontoxic, moderately toxic, and highly toxic) based upon the percent of survival was best for highly toxic sediments. An analysis of test precision based upon the variance among replicates within a test indicated that the measured survival rate for a sample may vary by up to 12 percentage points from the actual response.  相似文献   

3.
Many fields in environmental analytical chemistry deal with very low limits and thresholds as set by governmental legislations or transnational regulations. The need for the accuracy, comparability and traceability of analytical measurements in environmental analytical chemistry has significantly increased and total uncertainties are even asked for by accreditation bodies of environmental laboratories. This paper addresses achieving these goals to guarantee accuracy, quality control, quality assurance or validation of a method by means of certified reference materials. The assessment of analytical results in certified reference materials must be as accurate as possible and every single step has to be fully evaluated. This paper presents the SI-traceable certification of Cu, Cr, Cd and Pb contents in geological and environmentally relevant matrices (three sediments and one fly ash sample). Certification was achieved using isotope dilution (ID) ICPMS as a primary method of measurement. In order to reduce significantly the number of analytical steps and intermediate samples a multiple spiking approach was developed. The full methodology is documented and total uncertainty budgets are calculated for all certified values. A non-element specific sample digestion process was optimised. All wet chemical digestion methods examined resulted in a more or less pronounced amount of precipitate. It is demonstrated that these precipitates originate mainly from secondary formation of fluorides (essentially CaF2) and that their formation takes place after isotopic equilibration. The contribution to the total uncertainty of the final values resulting from the formation of such precipitates was in general < 0.1% for all investigated elements. Other sources of uncertainty scrutinised included the moisture content determination, procedural blank determination, cross-contamination from the different spike materials, correction for spectral interferences, instrumental background and deadtime effects, as well as the use of either certified values or IUPAC data in the IDMS equation. The average elemental content in the sediment samples was 30-130 micrograms g-1 for Pb, 0.5-3 micrograms g-1 for Cd and 50-70 micrograms g-1 for Cu. Cr was measured in one sample and was about 60 micrograms g-1. The concentrations in the fly ash sample were up to 2 orders of magnitude higher. Expanded uncertainty for the investigated elements was about 3% (coverae factor k = 2) except for Cr, (measured by high resolution ICPMS), for which the expanded uncertainty was about 7% (k = 2).  相似文献   

4.
Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.  相似文献   

5.
The results of a test of interlaboratory comparability for the determination of copper complexation capacity and copper-ligand complex formation constant are presented. Eight water samples comprising, six natural waters, a synthetic ligand solution and a blank solution were analysed by seven laboratories using their own methods of complexation titration. Given the wide variation that might have been possible, relatively good comparability was demonstrated amongst the variety of methods for determining copper complexation capacity. The complexation capacity data largely satisfied the predefined criterion of agreement to within 50%. This provides support for the use of metal speciation criteria in the regulation of copper in the environment. Data for the determination of complex formation constants were of poorer comparability, ranging between 10(7) and 10(12) for the same water.  相似文献   

6.
为了解当前不同来源环境空气气态污染物(CO、SO2、NO)标气质量状况,选择12家主流气态污染物(CO、SO2、NO)标气制造商,分别匿名采购3种气态污染物标气,建立2家参考实验室共同测试的模式和计量溯源一致性评价方法,对标气进行测试后,采用En值法评价其定值准确性,同时评估其技术资料完整性。结果显示:12家制造商的72瓶有证标气中,有9瓶标气定值结果准确性评价为不合格,涉及5个制造商来源,其中NO作为反应性气体,不合格标气数量最多,占比达20.8%;12家制造商中8家技术资料完整。鉴于标准气体对气态污染物监测结果的准确性、可比性和可溯源性具有重要意义,建议进一步加强标气质量事中事后监管和行业评估,推动制造商不断提高标气生产水平。标气使用者则应尽量选择质量可靠的有证标气。  相似文献   

7.
A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.  相似文献   

8.
为研究不同实验室藻密度监测数据的可靠性,现场采集了藻密度样品,处理为现场平行样和实验室前处理后平行样2种,分别由5家实验室的6名技术人员开展检测分析。参考相关技术规范要求,结合其他领域相似工作的成功应用案例,采用Z比分数法对分析结果开展藻密度实验室间比对。结果表明,数据的相对偏差均符合技术规范要求;对藻密度进行数据直接比对和对数转换后比对,各实验室对现场平行样和实验室前处理后平行样的检测结果均为合格;分析方法原理导致藻密度手工监测的绝对数值偏差较大,对当前的太湖水华预警工作适用性不高。  相似文献   

9.
Methodologies for the environmental analysis of total antimony and aqueous chemical speciation are critically reviewed, including preparation techniques for aqueous and solid matrices and the determination of solid state partitioning and recommendations are given for future research directions. Concentrations of total antimony commonly present in aqueous and solid environmental samples are readily determined using present day analytical techniques. This has resulted primarily from technological advances in microwave digestion for solid matrices and the development of plasma based analyte detection systems. ICP-AES and ICP-MS techniques are both utilised for the environmental analysis of total antimony concentrations. However, ICP-MS is increasingly favoured as a result of reduced spectral interferences and the potential for analyte detection in the pg mL(-1) range. Determination of aqueous antimony speciation presents a number of complex analytical challenges and highly selective separation and identification techniques are required prior to detection. The majority of published techniques including common applications of hydride generation are insufficiently selective for the determination of intrinsic chemical speciation and often only oxidation state data are obtained. The recent in-line applications of HPLC-ICP-MS offer the potential for highly selective separations of aqueous antimony species and determination of detailed chemical speciation data. However, considerable development work is required to optimise chromatographic separations and identify uncharacterised species resident in environmental systems. Analytical techniques to aid the determination of antimony's associations with solid environmental matrices include the application of chemical extraction procedures and leaching experiments. To date, this area of analytical research has received little attention and further studies are required to elucidate this aspect of antimony's environmental chemistry.  相似文献   

10.
Certified reference materials (CRMs) are an essential part of the quality assurance (QA) necessary for the reliable analytical measurement of nutrients in seawater. The CRMs currently available for these analyses are not matrix matched to marine samples. QUASIMEME routinely produces test materials for the nutrients in seawater and nutrients in estuarine water and low-salinity open water Laboratory Performance Studies (LPS) that are both homogeneous and stable. QUASIMEME, in conjunction with Eurofins Scientific, Denmark have produced two reference materials (RMs). The homogeneity testing and preliminary stability studies were carried out by QUASIMEME, and the results are presented in this article. Participants of the QUASIMEME LPS who demonstrated satisfactory long-term performance for the analysis of nutrients in seawater and nutrients in estuarine water and low-salinity open water were invited to take part in the certification exercise. Twenty laboratories returned data, a summary of which is also presented. The certification and long-term stability testing and additional data analysis were carried out by Eurofins Scientific, Denmark, and are outwith the scope of this article and not reported here. Eurofins Scientific, Denmark have marketed these RMs as part of their range of VKI Reference Materials (further information is available from eurofins@eurofins.dk).  相似文献   

11.
Elutriate bioassays are among numerous methods that exist for assessing the potential toxicity of sediments in aquatic systems. In this study, interlaboratory results were compared from 96-h Ceriodaphnia dubia and Pimephales promelas static-renewal acute toxicity tests conducted independently by two laboratories using elutriate samples prepared from the same sediment. The goal of the study was to determine if the results from the elutriate tests were comparable between two U.S. Environmental Protection Agency (USEPA) laboratories when different elutriate preparation procedures were employed by each lab. Complete agreement in site characterization was attained in 22 of the 25 samples for both bioassays amongst each lab. Of the 25 samples analyzed, 10 were found to be toxic to at least one of the species tested by either laboratory. The C. dubia elutriate tests conducted by the National Exposure Research Laboratory (NERL) indicated that 7 of the 25 sediment samples were toxic, while 8 sediment samples were characterized as such in testing conducted by USEPA Region 6 (Region 6). The P. promelas elutriate tests conducted by NERL determined 8 samples as toxic, while Region 6 tests displayed toxicity in 5 of the samples. McNemar's test of symmetry for C. dubia (S?=?0.33, p?=?0.5637) and P. promelas (S?=?3.0, p?=?0.0833) tests indicated no significant differences in designating a site toxic between NERL and Region 6 laboratories. Likewise, Cohen's kappa test revealed significant agreement between NERL and Region 6 C. dubia (K?=?0.7148, p?<?0.01) and P. promelas (K?=?0.6939, p?<?0.01) elutriate tests. The authors conclude that differences in interlaboratory elutriate preparation procedures have no bearing on the ability of either the C. dubia or P. promelas bioassay testing methods to detect toxicity while yielding similar results.  相似文献   

12.
浅谈环境监测实验室设备管理   总被引:8,自引:1,他引:7  
针对目前实验室认可和实验室资质认定评审中环境监测实验室普遍存在问题,提出正确实施仪器设备量值溯源、期间核查、维护,编写仪器设备使用维护规程,制定仪器设备的校准和/或检定(验证)、确认的总体要求,完善仪器设备档案管理,确保管理体系持续有效运行。  相似文献   

13.
A sediment sample from the intertidal mudflats of the Tagus estuary was prepared, homogenised and distributed globally to laboratories as the IAEA-408 intercomparison material for the analyses of organochlorinated pesticides, PCBs and petroleum hydrocarbons (PHs). A total of 48 laboratories from 36 countries reported their results. The data from participants show that there still remain some difficulties with the accurate determination of organic contaminants such as pesticides and polycyclic aromatic hydrocarbons (PAHs). More consistent interlaboratory results were obtained for PCBs congeners. The final results of this intercomparison exercise enable individual participants to assess their performance and, where necessary, to introduce appropriate modifications in their analytical procedures. Furthermore, as a series of statistical criteria was fulfilled for a number of compounds, the sample IAEA-408 can now be used as a reference material for quality control in the determination of some persistant organic pollutants (POPs) in marine sediment samples.  相似文献   

14.
根据实验室资质认定对于方法确认的要求,结合环境监测实验室的特点,提出了新项目方法确认的具体步骤,并分析了其中存在的常见问题。指出在方法确认过程中,应严格按照标准方法和监测技术规范进行全过程试验,尤其不能忽视采样现场实验、空白实验和检出限的测定。建议在精密度与准确度检验过程中,使用高、中、低不同浓度的有证标准样品,实际样品加标回收,比对试验(方法比对、人员比对、实验室间比对),增加分析次数等多种手段,确保新项目开展的可靠性。  相似文献   

15.
测量不确定度评估是实验室检测能力的体现,能力验证是实验室质量控制的有效方法,对环境监测领域实验室采用能力验证数据进行测量结果不确定度评估方法进行了研究。依据Nordtest准则,根据实验室内再现性标准差和测量偏倚,评估了重铬酸钾法测定水中质量浓度为100 mg/L的化学需氧量测量结果的相对不确定度为6.00%。该评估方法避免了ISO GUM评定方法自下而上不确定度评估过程的繁琐,还充分考虑了实验室内外误差的来源,能够促进环境监测结果不确定度评定的一致性。  相似文献   

16.
Reliable results for the determination of trace elements in urban and industrial wastewaters are of paramount importance for both checking the performance of sewage treatment and for detecting possible urban or industrial contamination sources. The quality control of measurements should in principle rely on external tools such as certified reference materials (CRM), which should represent, as closely as possible, the matrix of samples currently analysed, e.g., in the frame of environmental monitoring. To date, however, no CRM representatives of wastewater composition are available, which limits the possibility for control laboratories to check their QC externally. To fill this gap, the European Commission's Standards, Measurements and Testing Programme (formerly BCR) has started a European collaborative project of which the aim is to test the feasibility of preparation of wastewater reference materials and the analytical state-of-the-art to enable the certification of trace elements in such matrices. This paper presents the results of the first phase of this project, namely the feasibility study and the results of an interlaboratory trial.  相似文献   

17.
An overview is presented of sampling techniques and flow injection analysis (FIA) methods for low concentrations of Fe, Mn and Al in filtered seawater. On the basis of sampling procedures, filtration techniques, accuracy, blanks, detection limits, intercalibration results and oceanographic consistency, the feasibility of these FIA methods was evaluated. It was found that these metals could be measured on board with a minimum risk of contamination and with good accuracy even at low subnanomolar levels (<0.5 nM). Results for reference seawater were in the case of Fe-FIA and Mn-FIA in excellent agreement with the certified values. Data from samples analyzed by Fe-FIA and by cathodic stripping voltametry (CSV) compared well, as did Mn-FIA and GFAAS. All three methods gave results that were mostly in good agreement with data from the same ocean regions published by other research groups. Two different types of surface water sampling were also tested and compared, namely conventional hand filling of a sample bottle from a rubber dinghy away from the ship, and underway pumping of seawater using a 'tow fish'. The latter method gave the best results. Also, conventional membrane filtration and cartridge filtration for large volume filtration were compared using Fe and Al data from water column samples. Good agreement was found for both filter types, although for defining dissolved metal species the latter filter type was preferred.  相似文献   

18.
Control of workplace exposure to beryllium is a growing issue in the United States and other nations. As the health risks associated with low-level exposure to beryllium are better understood, the need increases for improved analytical techniques both in the laboratory and in the field. These techniques also require a greater degree of standardization to permit reliable comparison of data obtained from different locations and at different times. Analysis of low-level beryllium samples, in the form of air filters or surface wipes, is frequently required for workplace monitoring or to provide data to support decision-making on implementation of exposure controls. In the United States and the United Kingdom, the current permissible exposure level is 2 microg m(-3) (air) and the United States Department of Energy has implemented an action level of 0.2 microg m(-3) (air) and 0.2 microg/100 cm(2) (surface). These low-level samples present a number of analytical challenges, including (1) a lack of suitable standard reference materials, (2) unknown robustness of sample preparation techniques, (3) interferences during analysis, (4) sensitivity (sufficiently low detection limits), (5) specificity (beryllium speciation) and (6) data comparability among laboratories. Additionally, there is a need for portable, real-time (or near real-time) equipment for beryllium air monitoring and surface wipe analysis that is both laboratory-validated and field-validated in a manner that would be accepted by national and/or international standards organizations. This paper provides a review of the current analytical requirements for trace-level beryllium analysis for worker protection and also addresses issues that may change those requirements. The current analytical state of the art and relevant challenges facing the analytical community will be presented, followed by suggested criteria for real-time monitoring equipment. Recognizing and addressing these challenges will present opportunities for laboratories, research and development organizations, instrument manufacturers and others.  相似文献   

19.
In order to control the quality of butyl- and phenyltin compound determinations in sediment, the Standards, Measurements and Testing Programme (formerly BCR) of the European Commission has started a project, the final aim of which is to certify a freshwater sediment for its contents of a range of organotin compounds (mono-, di- and tributyltin, and mono-, di- and triphenyltin). The first part of this project involved an interlaboratory study which aimed to test the feasibility of preparation of candidate freshwater sediment reference material and to detect and remove most of the pitfalls observed in organotin determinations. This paper presents the main results of this interlaboratory study carried out prior to the certification campaign. The agreement obtained among laboratories for the six compounds determined was considered to reflect the state-of-the-art and was encouraging enough to decide upon the organisation of a certification campaign, which will be concluded in June 1999.  相似文献   

20.
The development of a monitoring network for chemical speciation of elements of aerosol and sediment samples collected at Lake Balaton has been carried out. Sequential leaching procedures for the determination of the distribution of elements in aerosols (3 steps) and sediments (4 steps) were used. These methods were recently successfully applied to describe environmentally mobile and stable fractions of toxic metals. In aerosol matrices the partition of elements was accomplished by particle size and chemical bonding. In sediments the distribution was performed by chemical bonding. The processes are called fractionation of elements. Particular attention was paid to distinguishing between environmentally mobile and environmentally immobile fractions because these represent the two extreme modes by which the metals are bound to solid matrices. The monitoring objectives were to assess pollution effects on man and his environment and to identify any possible cause and effect relationship between pollutant concentrations and health effects. The results of dry and wet deposition rates showed that most of the toxic metals were dissolved in an aqueous phase and the wet deposition played an important role. It has been found that, while the concentration of Cd and Pb in aerosols is low (0.7 and 29 ng m(-3), respectively), environmentally mobile fractions are considerable. Based upon the data it can be concluded that the effect of the anthropogenic sources on the quality of the lake is minor. This has been the first attempt to correlate speciation results between aerosols and sediments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏