首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Low-cost treatment of landfill leachate using peat   总被引:6,自引:0,他引:6  
The EU Landfill Directive obliges member states to collect and treat leachate from landfill sites. In regions of high population density, this is commonly achieved through discharge of the leachate to the municipal sewerage system. In Ireland, rural landfills can be a long distance from a suitable sewerage system, resulting in high transportation costs. On-site treatment systems, when used elsewhere, are mainly aerobic treatment systems, which are costly to construct and operate. There is a particular need for low-cost, low-maintenance leachate treatment systems for small low-income landfills, and for closed landfills, where long-term running costs of aerobic systems may be unsustainable. In 1989, this research work was initiated to investigate the use of local peat for the treatment of leachate from a small rural landfill site. In 1997, following the award of grant-aid under the EU LIFE Programme, a full-scale leachate treatment plant was constructed, using local un-drained peat as the treatment medium. When the LIFE Project ended in February 2001, leachate treatment research continued at the site using a pre-treated peat as the treatment medium. The treatment levels achieved using both types of peat are discussed in this paper. It is concluded that landfill leachate may be successfully treated using a low-cost peat bed to achieve almost 100% removal of both BOD and ammonia.  相似文献   

2.
3.
Hydraulic properties of waste and cover soil from Kimpo Metropolitan Landfill were experimentally measured by laboratory tests. The degree of compaction was changed to identify the effect on hydraulic conductivity, field capacity, and permanent wilting point. Properties were utilized in developing a reliable numerical tool for leachate analysis. HELP, a simulation model for hydrologic evaluation of landfill performance, was adopted for that purpose. For calibration, results from simulation using the parameter values measured by laboratory tests were compared against the field data. The model was applied to predict the leachate level change according to the degree of compaction and cover soil thickness variation. It was found that the increase in the degree of compaction for intermediate cover soil and waste results in the decrease of field capacity and hydraulic conductivity, hence, the increase of leachate level. The effect of cover layer thickness on the leachate level was minor. Based on the findings from laboratory and numerical experiments, a guideline for reclamation practice was recommended.  相似文献   

4.
The aim of this research was to investigate some of the physical and mechanical properties of concrete mixed under laboratory conditions, where different proportions of coarse aggregate materials were substituted by porcelain from sanitary installations. The results of the tests show that the concrete produced has the same mechanical characteristics as conventional concrete, thus opening a door to selective recycling of sanitary porcelain and its use in the production of concrete.  相似文献   

5.
Two leaching tests were carried out, one with whole batteries and another with cross-cut batteries. In both cases, NEN 7343 (a Nederland’s Standard) procedure was followed using a municipal solid waste (MSW) landfill leachate as extraction solution. Seven fractions were collected corresponding to cumulative liquid/solid (L/S) ratio from 0.1 to 10.0. Those fractions were separately characterized in terms of pH, conductivity, redox potential, density, sulphate, chloride, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Sb, Tl and Zn. Results showed that the influence of the alkaline batteries in the landfill leachate composition varies with their physical integrity and with the L/S ratio, and several variations were observed throughout the tests. The leachate pH and redox potential increased as result of the contact with batteries, particularly pH in the test with the cross-cut batteries. The leachate density and conductivity did not change significantly with the whole batteries, in contrast with the test with cross-cut batteries.  相似文献   

6.
Landfill leachate (LL) usually contains low concentrations of heavy metals due to the anaerobic conditions in the methanogenic landfill body after degradation of easily degradable organic matter and the neutral pH of LL, which prevents mobilization and leaching of metals. Low average concentrations of metals were also confirmed in our extensive study on the rehabilitation of an old landfill site with vegetative landfill cover and LL recirculation after its treatment in constructed wetland. The only exception was chromium (Cr). Its concentrations in LL ranged between 0.10 and 2.75 mg/L, and were higher than the concentrations usually found in the literature. The objectives of the study were: (1) to understand why Cr is high in LL and (2) to understand the fate and transport of Cr in soil and vegetation of landfill cover due to known Cr toxicity to plants. The total concentration of Cr in LL, total and exchangeable concentrations of Cr in landfill soil cover and Cr content in the plant material were extensively monitored from May 2004 to September 2006. By obtained data on Cr concentration in different landfill constituents, supported with the data on the amount of loaded leachate, amount of precipitation and potential evapotranspiration (ETP) during the performance of the research, a detailed picture of time distribution and co-dependency of Cr is provided in this research. A highly positive correlation was found between concentrations of Cr and dissolved organic carbon (r = 0.875) in LL, which indicates the co-transport of Cr and dissolved organic carbon through the system. Monitoring results showed that the substrate used in the experiment did not contribute to Cr accumulation in the landfill soil cover, resulting in percolation of a high proportion of Cr back into the waste layers and its circulation in the system. No negative effects on plant growth appeared during the monitoring period. Due to low uptake of Cr by plants (0.10–0.15 mg/kg in leaves and 0.05–0.07 mg/kg in stems of Salix purpurea), the estimated Cr offtake from LL by plants represented only a small proportion of the LL Cr mass load during the observation period, resulting in no dispersion of Cr into the environment through leaf drop.  相似文献   

7.
This paper analyses the evolution of the physico-chemical characteristics of the leachate from the Central Landfill of Asturias (Spain), which has been operating since 1986, as well as different treatment options. The organic pollutant load of the leachate, expressed as chemical oxygen demand (COD), reached maximum values during the first year of operation of the landfill (around 80,000 mg/L), gradually decreasing over subsequent years to less than 5000 mg/L. The concentration of ammonium, however, has not decreased, presenting values of up to 2000 mg/L. When feasible, recirculation can greatly decrease the organic matter content of the leachate to values of 1500–1600 mg COD/L. Applying anaerobic treatment to leachates with a COD between 11,000 and 16,000 mg/L, removal efficiencies of 80–88% were obtained for organic loading rates of 7 kg COD/m3 d. For leachates with lower COD (4000–6000 mg/L), the efficiency decreased to around 60% for organic loading rates of 1 kg COD/m3 d.Applying coagulation–flocculation with iron trichloride or with aluminium polychloride, it was possible to reduce the non-biodegradable organic matter by 73–62% when treating old landfill leachate (COD: 4800 mg/L, BOD5: 670 mg/L), also reducing turbidity and colour by more than 97%. It is likewise possible to reduce the non-biodegradable organic matter that remains after biological treatment by adsorption with activated carbon, although adsorption capacities are usually low (from 15 to 150 mg COD/g adsorbent). As regards ammonium nitrogen, this can be reduced to final effluent values of 5 mg/L by means of nitrification/denitrification and to values of 126 mg/L by stripping at pH 12 and 48 h of stirring.  相似文献   

8.
The main objective of this study was to assess the feasibility of treating sanitary landfill leachate using a combined anaerobic and activated sludge system. A high-strength leachate from Shiraz municipal landfill site was treated using this system. A two-stage laboratory-scale anaerobic digester under mesophilic conditions and an activated sludge unit were used. Landfill leachate composition and characteristics varied considerably during 8 months experiment (COD concentrations of 48,552–62,150 mg/L). It was found that the system could reduce the COD of the leachate by 94% at a loading rate of 2.25 g COD/L/d and 93% at loading rate of 3.37 g COD/L/d. The anaerobic digester treatment was quite effective in removing Fe, Cu, Mn, and Ni. However, in the case of Zn, removal efficiency was about 50%. For the rest of the HMs the removal efficiencies were in the range 88.8–99.9%. Ammonia reduction did not occur in anaerobic digesters. Anaerobic reactors increased alkalinity about 3.2–4.8% in the 1st digester and 1.8–7.9% in the 2nd digester. In activated sludge unit, alkalinity and ammonia removal efficiency were 49–60% and 48.6–64.7%, respectively. Methane production rate was in the range of 0.02–0.04, 0.04–0.07, and 0.02–0.04 L/g CODrem for the 1st digester, the 2nd digester, and combination of both digesters, respectively; the methane content of the biogas varied between 60% and 63%.  相似文献   

9.
Oxidation of landfill leachate wastewater was studied in a transpiring-wall SCWO reactor, operated under varied temperature and pressure 320–430 °C, 18–30 MPa. Effect of temperature and pressure on COD and BOD removal efficiency was investigated. COD and BOD removal efficiency being 99.23%, 98.06% were achieved at 430 °C, 30 MPa, which increased with temperature and pressure. The modified pseudo first-order rate model was regressed from experimental data, taking into account the induction time (tind) effect. The resulting pre-exponential factor A and activation energy Ea were 34.86 s?1 and 32.1 kJ mol?1, respectively, assuming that the reaction order for feed wastewater (based on COD) and oxidant were first order and zero order, respectively.  相似文献   

10.
The possibility of in situ removal of heavy metals found in leachate generated at municipal solid waste landfills was studied through amendment of daily cover soil. Kahrizak landfill, which receives the waste generated at Tehran, was selected as the source of leachate and soil samples. Manganese and zinc were selected in this study. The soil sample taken from the Kahrizak site contained about 17% clay, which was presumed to have significant capability for removing manganese and zinc. This capability was assumed to be enhanced further through the addition of lime and consequently to improve the potential for chemical precipitation of the selected metals. The in situ removal experiment was accomplished through a set of seven columns filled with the sampled soil with varying contents of lime (i.e., from 0% to 6% by dry weight). Fresh leachate of low pH was added to the columns on a daily basis. Concentrations of manganese and zinc were measured in the influent and effluent during 40 days when biological clogging resulted in a condition of almost no outflow in the columns. The results indicated a substantial increase in removal efficiency through the addition of lime to the daily cover soil. Desorption resulting from the low pH of fresh leachate occurs at later stages compared to the column with no lime addition.  相似文献   

11.
The aim of our study was to evaluate biotreatability of mature municipal landfill leachate by using white rot fungus and its extracellular enzymes. Leachates were collected in one active and one closed regional municipal landfill. Both chosen landfills were operating for many years and the leachates generated there were polluted by organic and inorganic compounds. The white rot fungus Dichomitus squalens was able to grow in the mature leachate from the closed landfill and as it utilizes present organic matter as a source of carbon, the results were showing 60% of DOC and COD removal and decreased toxicity to the bacterium Aliivibrio fischeri. On the other hand, growth of the fungus was inhibited in the presence of the leachate from the active landfill. However, when the leachate was introduced to a crude enzyme filtrate containing extracellular ligninolytic enzymes, removal levels of COD and DOC reached 61% and 44%, respectively. Furthermore, the treatment led to detoxification of the leachate to the bacterium Aliivibrio fischeri and to reduction of toxicity (42%) to the plant Sinapis alba. Fungal and enzymatic treatment seems to be a promising biological approach for treatment of mature landfill leachates and their application should be further investigated.  相似文献   

12.
Leachate pollution is one of the main problems in landfilling. Researchers have yet to find an effective solution to this problem. The technology that can be used may differ based on the type of leachate produced. Coliform bacteria were recently reported as one of the most problematic pollutants in semi-aerobic (stabilized) leachate. In the present study, the performance of the Electro-Fenton process in removing coliform from leachate was investigated. The study focused on two types of leachate: Palau Borung landfill leachate with low Coliform content (200 MPN/100 m/L) and Ampang Jajar landfill leachate with high coliform content (>24 × 104 MPN/100 m/L). Optimal conditions for the Electro-Fenton treatment process were applied on both types of leachate. Then, the coliform was examined before and after treatment using the Most Probable Number (MPN) technique. Accordingly, 100% removal of coliform was obtained at low initial coliform content, whereas 99.9% removal was obtained at high initial coliform content. The study revealed that Electro-Fenton is an efficient process in removing high concentrations of pathogenic microorganisms from stabilized leachate.  相似文献   

13.

This article investigates the suitability of utilizing end of life rubber tyre particles in concrete as fine aggregate. Rubber ash and rubber fibers were used to develop two series of rubber ash concrete (series I) and hybrid concrete (series II) mixes. The natural fine aggregate was replaced by rubber ash (by volume of 5%, 10%, 15% and 20%) in series I; whereas in series II, the amount of rubber ash was kept constant at 10% and rubber fiber was introduced as replacement of fine aggregate (by volume of 5%, 10%, 15%, 20% and 25%). The concrete mixes were evaluated for compressive strength, flexural strength, resistance to impact loading, fatigue loading, water penetration and shrinkage strain was evaluated. It was observed that inclusion of rubber ash resulted in the improvement of impact resistance of concrete. The results also show that up to 10% rubber ash and rubber fibers can be utilized as fine aggregate to develop feasible and durable rubberized concrete pavements, crash barriers and paver blocks.

  相似文献   

14.
With limited assessment, leachate treatment of a specified landfill is considered to be a significant source of greenhouse gas (GHG) emissions. In our study, the cumulative GHG emitted from the storage ponds and process configurations that manage fresh or aged landfill leachate were investigated. Our results showed that strong CH4 emissions were observed from the fresh leachate storage pond, with the fluxes values (2219–26,489 mg C m?2 h?1) extremely higher than those of N2O (0.028–0.41 mg N m?2 h?1). In contrast, the emission values for both CH4 and N2O were low for the aged leachate tank. N2O emissions became dominant once the leachate entered the treatment plants of both systems, accounting for 8–12% of the removal of N-species gases. Per capita, the N2O emission based on both leachate treatment systems was estimated to be 7.99 g N2O–N capita?1 yr?1. An increase of 80% in N2O emissions was observed when the bioreactor pH decreased by approximately 1 pH unit. The vast majority of carbon was removed in the form of CO2, with a small portion as CH4 (<0.3%) during both treatment processes. The cumulative GHG emissions for fresh leachate storage ponds, fresh leachate treatment system and aged leachate treatment system were 19.10, 10.62 and 3.63 Gg CO2 eq yr?1, respectively, for a total that could be transformed to 9.09 kg CO2 eq capita?1 yr?1.  相似文献   

15.
Mature landfill leachate is typically non-biodegradable. A combination process was developed that includes coagulation, Fenton oxidation, and biological aerated filtering to treat biologically-produced effluent. In this process, coagulation and Fenton oxidation were applied in order to reduce chemical oxygen demand (COD) organic load, and enhance biodegradability. Poly-ferric sulfate (PFS) at 600 mg l?1 was found to be a suitable dosage for coagulation. For Fenton oxidation, an initial pH of 5, a total reaction time of 3 h, and an H2O2 dosage of 5.4 mmol l?1, with a (H2O2)/n(Fe2+) ratio of 1.2 and two-step dosing were selected to achieve optimal oxidation. Under these optimal coagulation and Fenton oxidation conditions, the COD removal ratios were found to be 66.67% and 56%, respectively. Following pretreatment with coagulation and Fenton oxidation, the landfill leachate was further treated using a biological aerated filter (BAF). Our results show that COD was reduced to 75 mg l?1, and the color was less than 10 degrees.  相似文献   

16.
Considering the quality of design and construction of landfills in developing countries, little information can be derived from randomly taken leachate samples. Leachate generation and composition under monsoon conditions have been studied using lysimeters to simulate sanitary landfills and open cell settings. In this study, lysimeters were filled with domestic waste, highly organic market waste and pre-treated waste. Results over two subsequent dry and rainy seasons indicate that the open cell lysimeter simulation showed the highest leachate generation throughout the rainy season, with leachate flow in all lysimeters coming to a halt during the dry periods. More than 60% of the precipitation was found in the form of leachate. The specific COD and TKN load discharged from the open cell was 20% and 180% more than that of the sanitary landfill lysimeters. Types of waste material and kind of pre-treatment prior to landfilling strongly influenced the pollutant load. Compared to the sanitary landfill lysimeter filled with domestic waste, the specific COD and TKN load discharged from the pre-treated waste lysimeter accounted for only 4% and 16%, respectively. Considering the local settings of tropical landfills, these results suggest that landfill design and operation has to be adjusted. Leachate can be collected and stored during the rainy season, and recirculation of leachate is recommended to maintain a steady and even accelerated degradation during the prolonged dry season. The open cell approach in combination with leachate recirculation is suggested as an option for interim landfill operations.  相似文献   

17.
Water-swelling material (WSM) is a fluid sealant obtained by blending high-absorbency polymer, a filler, and a solvent by using a synthetic resin elastomer as the base material. In this research, we studied experimentally the composition of WSM, the extent of swelling, the strength of the WSM and the long-term performance of the swelling material used as a jointed water cutoff treatment material at waste landfill sites. One of the results was that adjusting the degree of etherification of the high-absorbency polymer, which is a component of the WSM, and the resin content of the synthetic elastomer contributed to improvement of the swelling of the sealant and the strength of the swelling material. Further, in long-term tests, the strength of the WSM tended to become stabilized and it was confirmed that it had sufficient pressure resistance for use in coastal landfill sites, where its application as a water cutoff treatment material is being considered.  相似文献   

18.
Landfill leachates sampled during and after an accidental landfill fire were analysed and the levels of selected metals and chemical compounds compared to those occurring in the leachate under normal conditions. The fire at the landfill site was put out by excavation and cooling by use of water. The investigation during the fire and fire fight revealed a moderate increase in the level of nitrogen and also in pH and conductivity. Heavy metals and COD in the leachate showed considerably increased levels. In general, the determined variables appeared to normalise within one week after the fire was extinguished. It can be concluded that landfill fires extinguished by excavation may lead to elevated leachate levels of especially COD and heavy metals, but that this is only a short-term effect.  相似文献   

19.
20.
In order to investigate the effect of raw leachate on anaerobic digestion of food waste, co-digestions of food waste with raw leachate were carried out. A series of single-phase batch mesophilic (35 ± 1 °C) anaerobic digestions were performed at a food waste concentration of 41.8 g VS/L. The results showed that inhibition of biogas production by volatile fatty acids (VFA) occurred without raw leachate addition. A certain amount of raw leachate in the reactors effectively relieved acidic inhibition caused by VFA accumulation, and the system maintained stable with methane yield of 369–466 mL/g VS. Total ammonia nitrogen introduced into the digestion systems with initial 2000–3000 mgNH4–N/L not only replenished nitrogen for bacterial growth, but also formed a buffer system with VFA to maintain a delicate biochemical balance between the acidogenic and methanogenic microorganisms. UV spectroscopy and fluorescence excitation–emission matrix spectroscopy data showed that food waste was completely degraded.We concluded that using raw leachate for supplement water addition and pH modifier on anaerobic digestion of food waste was effective. An appropriate fraction of leachate could stimulate methanogenic activity and enhance biogas production.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号