首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this study was to determine whether there is increased leakage of neuron-specific enolase (NSE) and S-100 protein into amniotic fluid in pregnancies with neural tube defects, since both these proteins are produced by neural tissue, and to compare the value of these substances for detecting such defects with that of the more conventional techniques of alpha-fetoprotein (AFP) and acetylcholinesterase (AChE) gel electrophoresis. Amniotic samples from 25 mid-pregnancies (15–17 weeks' gestation) with neural tube defects (14 with open spina bifida and 11 with anencephaly) and from seven mid-pregnancies with abdominal wall defects were compared with a control material consisting of 80 amniotic fluid samples from 80 consecutive mid-pregnancy amniocenteses, with normal karyotypes and AFP concentrations. All of the above cases of abnormalities were primarily detected through increased AFP levels in the amniotic fluid. Amniotic fluid samples from 13 pregnancies with fetuses with autosomal chromosomal abnormalities and seven amniotic fluid samples contaminated with blood were also included in the investigation. It is concluded from the results that the conventional AFP assay combined with AChE gel electrophoresis is the best method for screening amniotic fluid for neural tube defects and defects of the abdominal wall. Neither NSE nor S-100 assay alone proved to be superior for the detection of these cases in mid-trimester amniotic fluid. The S-100 assay, however, could give additional information in cases where AChE gel electrophoresis is not decisive; for example, in samples contaminated with blood.  相似文献   

2.
Anencephaly in twin B was accompanied by elevated amniotic fluid alpha-fetoprotein (AFP) and a positive acetylcholinesterase (AChE) band on gel electrophoresis in both twin sacs, although twin A was normal. AChE results did not help distinguish the false positive AFP in this set of twins, implying that AChE may diffuse transamniotically as has been previously postulated for AFP. In light of the low concordance rate for neural tube defects in twins, patient counselling in this situation must include the information that AFP and AChE may be falsely elevated in normal twin when the other twin has a neural tube defect.  相似文献   

3.
Isoelectric focusing (IEF) of amniotic fluid α-fetoprotein (AFP) in thin-layer polyacrylamide gels containing 8 M urea followed by immunoblotting reveals at least nine bands, band I lying next to the cathode. Compared with 298 amniotic fluid samples from normal pregnancies, we found that the density of band V was increased in seven cases of fetal death. In 16 amniotic fluid samples from pregnancies with open neural tube defects (ONTO), band V disappeared or was markedly decreased. In seven cases with elevated AFP and positive acetylcholines-terase (AChE) due to contamination with fetal blood, no difference in pattern was observed compared with samples from normal pregnancies. It is suggested that IEF of AFP and subsequent immunoblotting are an apparently diagnostic test for ONTD and intrauterine fetal death (IUFD).  相似文献   

4.
In the present study, a recently reported immunochemical technique for measuring acetylcholinesterase (AChE) in amniotic fluid utilizing the 4F19 antibody was compared with the widely utilized polyacrylamide gel technique to determine whether the immunochemical assay provided an advantage in separating unaffected pregnancies from those associated with open spina bifida (OSB) and open ventral wall defects (OVWD). The study included (1) 73 amniotic fluid samples from unaffected pregnancies [alpha-fetoprotein (AFP) < 2 MoM] with no visible gel AChE band, (2) nine bloodstained samples from unaffected pregnancies (AFP 2·2–4·0 MoM) with visible gel AChE bands, (3) 18 samples associated with OSB (AFP 2·2–7·0 MoM) with visible gel AChE bands, and (4) 20 samples associated with OVWD (AFP 3·2–53·5 MoM) with visible gel AChE bands. The immunochemical assay produced ranges of measurements in the four respective categories as follows: (1) 2–60 arbitrary units (AU): (2) 14–69 AU, (3) 61–593 AU, and (4)22–476 AU. Eight of the nine unaffected pregnancies with visible gel AChE bands had immunochemical measurements below the highest measurement for the samples with no visible AChE band (60 AU), as did five out of 20 OVWD pregnancies. Two of the OSB cases had values of 61 and 62 AU. These data indicate that the 4F19 specific monoclonal antibody to AChE is capable of distinguishing unaffected from affected pregnancies with reasonable reliability but that more work needs to be done to establish the extent of overlap between the unaffected and affected populations.  相似文献   

5.
We have investigated the occurrence of acetylcholinesterase (AChE) (E.C.3.1.1.7) in fetal serum, amniotic fluid and maternal serum using an immuno-chemical assay-technique employing both polyclonal and monoclonal antibodies. Fetal serum had increased amounts of AChE, which is due to an increase in the 10.5S form of the enzyme. This form was also found in amniotic fluids of pregnancies with a fetal neural tube defect (NTD), but not in normal amniotic fluid. The increase in amniotic fluid AChE was however, not reflected in the maternal serum.  相似文献   

6.
A quantitative method for cholinesterases in amniotic fluid using the non-specific substrate α naphthyl acetate and the cholinesterase-specific inhibitor, eserine, is described. This assay was used to test 671 samples of amniotic fluid. The diagnoses for fetal ONTDs, based on the levels of AChE + ChE, were compared with those made for the same samples by the AFP method. Correct diagnoses were made by both methods with amniotic fluid from 35 women carrying fetuses with ONTDs and 631 carrying normal fetuses. There were five false-positive test results for normal fetuses by both methods when the cut-off points were 5 standard deviations above the mean for AFP and above the upper limit of the normal range (7. 5 milliunits) for cholinesterase (AChE + ChE). None of the false-positive samples from either method had the acetylcholinesterase band of activity characteristic of ONTDs after gel electrophoresis. In addition to the above 671 samples, 37 pregnancies with serious fetal abnormalities other than ONTDs were tested. Two were identified by both the AFP and AChE + ChE methods, two more by AFP assay and one other by the AChE + ChE assay.  相似文献   

7.
Separately identified samples of amniotic fluid and extraembryonic coelomic fluid obtained by high resolution transvaginal ultrasound-guided amniocentesis from 32 women between 7 and 12 weeks of pregnancy were analysed for human chorionic gonadotrophin (hCG) and alpha-fetoprotein (AFP). There was a highly significant difference between the hCG levels in amniotic fluid (median level 6.3 U/ml; range 1.6–310.0 U/ml) and those in extraembryonic coelomic fluid (median level 400.0U/ml; range 135.0–2250.0U/ml) (p<0.001; Mann-Whitney U/–test). The levels of AFP were very similar in amniotic fluid (median 26.0 kU/ml; range 10.0–116.5 kU/ml) and extraembryonic coelomic fluid (median level 24.1 kU/ml; range 12.4–94.4 kU/ml).  相似文献   

8.
An association between various abnormal mid-trimester maternal serum analyte values and adverse perinatal outcome has been reported. From an original sample of 14 857 women, we observed five women who were ‘screen-positive’ for both neural tube defects [maternal serum alpha-fetoprotein (MSAFP) ≥2·5 multiples of the median] and Down syndrome [risk ≥1/274 using MSAFP, maternal serum unconjugated oestriol (MSuE3), maternal serum human chorionic gonadotropin (MShCG), and maternal age]. The four patients who elected to undergo amniocentesis all demonstrated both normal karyotype and normal amniotic fluid AFP levels. All five cases were associated with intrauterine growth retardation (IUGR) and abnormal pregnancy outcomes. Two cases exhibiting severe IUGR on ultrasound examination were terminated at 19·1 and 21·2 weeks, respectively; the former also exhibited fetal calcifications and positive maternal serology for toxoplasmosis. In another case, fetal demise occurred at 36 weeks' gestation in a patient who had been treated for syphilis in the second trimester. Neither infection was confirmed in fetal tissue studies. Though resulting in live births, the remaining two cases required operative deliveries; emergency Caesarean sections for fetal distress were performed at 38 and 32 weeks, respectively, the latter case being associated with severe pre-eclampsia. We conclude that elevated mid-trimester MSAFP levels concurrent with maternal serum analyte values associated with increased risk for fetal Down syndrome may presage a poor perinatal outcome, particularly IUGR and possibly congenital infection.  相似文献   

9.
Seventeen centres from Australia, Britain, France, and the United States collaborated in a study to compare amniotic fluid acetylcholinesterase (AChE) determination by gel electrophoresis and amniotic fluid alpha-fetoprotein (AFP) measurement as diagnostic tests for open neural tube defects. The study was based on 32 642 women with singleton pregnancies (including 428 with open spina bifida and 238 with anencephaly) who had an amniocentesis at 13–24 weeks' gestation. The AChE test yielded a detection rate for open spina bifida of 99 per cent (95 per cent confidence interval 98–100 per cent), 98 per cent for anencephaly (95 per cent confidence interval 96–100 per cent), and a false-positive rate of 0.34 per cent (95 per cent confidence interval 0.28–0.40 per cent) excluding miscarriages, intrauterine death, and serious fetal abnormalities. The false-positive rate was 0.30 per cent among the 13 centres that used a specific AChE inhibitor in the test. Comparable rates for the AFP test were less favourable. (For example, the open spina bifida detection rate was 90 per cent and the false-positive rate was 0.46 per cent using the cut-off levels specified in the U.K. Collaborative AFP Study.) The AChE false-positive rate was lower in samples that were not bloodstained (0.16 per cent) than in those that were (2.4 per cent). It was higher in women who had an amniocentesis on account of a raised maternal serum AFP level (0.56 per cent) than in those who had one for other reasons (0.29 per cent). The best results were obtained by a combination of the two tests, an effective and economical policy being to perform the AFP measurement on all amniotic fluid samples and an AChE test on samples with AFP levels greater than or equal to 2.0 multiples of the normal median (about 5 per cent of all samples). Using this policy, the open spina bifida detection rate was 96 per cent and the false-positive rate was 0.14 per cent (0.06 per cent for samples that were not bloodstained and 1.2 per cent for those that were; 0.40 per cent for women with raised serum AFP levels and 0.09 per cent for other women). This policy offers a useful improvement to the prenatal diagnosis of open spina bifida.  相似文献   

10.
Twins concordant for elevated alpha-fetoprotein (AFP) and acetylcholinesterase (AChE) and discordant for neural tube defect (NTD) and sex are reported. A literature review reveals instances of termination of twin pregnancies with one normal and one abnormal fetus, partly based on concordant high AFP and positive AChE (although discordant on ultrasound examination). The levels of AFP and AChE in twin pregnancies are probably a function of the number of layers of fetal membranes separating twin sacs: dichorionic, diamniotic membranes allow transfer of AFP; monochorionic, diamniotic membranes allow transfer of both AFP and AChE. Cautious interpretation of biochemical findings and reliance on high resolution ultrasonography are suggested.  相似文献   

11.
Forty-two open neural tube defects (NTDs) were identified in our series of 7440 amniocenteses tested between 11 and 15 weeks of gestation. Using a cut-off of ≥2.0 MOM, the detection rate for open NTDs was 95 per cent; 100 per cent each for anencephaly and spina bifida; and 78 per cent for encephalocele. Two encephaloceles had AFP levels less than 2.0 MOM and negative AChEs. Thirty-four (81 per cent) of these NTDs were tested between 13 and 15 weeks and 8 (19 per cent) before 13 weeks. There were 0.6 per cent false positives by AFP (excluding serious abnormalities and fetal death) and 0.1 per cent after AChE. The likelihood of an open NTD after an elevated AFP (≥2.0 MOM) was 24 and 77 per cent for any serious abnormality. These results, when combined with an earlier study, indicate that amniotic fluid AFP appears to be as sensitive a test for open NTDs between 13 and 15 weeks as between 16 and 20 weeks. Additional experience is necessary to determine this before 13 weeks.  相似文献   

12.
Alpha-fetoprotein (AFP) concentration and gamma-glutamyltranspeptidase (GGT) activity have been analysed in amniotic fluid from a series of 65 pregnancies with autosomal trisomies. AFP values were reduced on average to 60 per cent of normal in cases of trisomy 21, but were not significantly different from normal in cases of trisomies 18 and 13. GGT activities were uniformly lower (44 per cent of normal) for all types of autosomal trisomy. A review of the literature indicates that over 85 per cent of Down's pregnancies but only 39 per cent of trisomy 18 and 13 pregnancies have amniotic fluid AFP levels below the normal median value, while the corresponding figures for GGT are 91 per cent for Down's syndrome and 96 per cent for trisomies 18 and 13.  相似文献   

13.
Amniotic fluid samples received for routine prenatal diagnosis of open neural tube defects were used for a study to compare amniotic fluid acetylcholinesterase (AChE) determination using a monoclonal antibody (4F19) enzyme antigen immunoassay and amniotic fluid alpha-fetoprotein (AFP) measurement as diagnostic tests for open neural tube defects. The study was based on 9964 women with singleton pregnancies and known outcome (including 6 with anencephaly and 18 with open spina bifida) having an amniocentesis at 14–23 weeks of gestation. The AChE immunoassay yielded detection rates for anencephaly of 100 per cent (95 per cent confidence interval (CI) 54·07–100 per cent), for open spina bifida of 100 per cent (95 per cent CI 81·47–100 per cent), for anterior abdominal wall defects of 20 per cent (95 per cent CI 0-51-71-64 per cent), and a false-positive rate of 0·22 percent (95 per cent CI 0·14–0·34 per cent) excluding anencephaly, open spina bifida, and anterior abdominal wall defects. For similar detection rates the false-positive rate of the AFP test was significantly higher, 0·74 per cent (95 per cent CI 0·58–0·94 per cent). On the basis of these findings, it is recommended that the technically simple AChE immunoassay should be used on all samples; the AFP test should only be used on the 0·5 per cent of the samples with concentrations of AChE activity ⩾ 8·5 nkat/1 for clear samples and blood-stained samples becoming clear after centrifugation, and ⩾ 25·0 nkat/1 for blood-stained samples that are discoloured after centrifugation; an AFP cut-off level of 2·0 MOM is recommended for this policy. Thereby, the detection rates for anencephaly, open spina bifida, and anterior abdominal wall defects would be 100, 100, and 20 per cent, respectively (95 per cent CIs 54·07–100, 81·47–100, and 0·51–71·64 per cent, respectively), and the false-positive rate would be 0·08 per cent (95 per cent CI 0·03–0·16 per cent) (excluding anencephaly, open spina bifida, and anterior abdominal wall defects).  相似文献   

14.
Intrauterine fetal demise (IUFD) in one of twins at 12 weeks of gestation was accompanied by markedly elevated maternal serum alpha-fetoprotein (AFP) at 17 and 18 weeks. Amniotic fluid AFP from the healthy surviving twin's sac at 18·5 and 23 weeks was also greatly increased along with a positive acetylcholinesterase (AChE) band. Persistently elevated AFP and positive AChE so long after fetal demise–-6·5 and 11 weeks post IUFD–-has not, to our knowledge, been previously described. In similar cases, high level ultrasound and careful placental examination at birth should be utilized to search for fetal abnormalities or multiple pregnancy with IUFD.  相似文献   

15.
The value of acetylcholinesterase (AChE) analysis as an adjunctive test to amniotic alpha fetoprotein (amAFP) for the diagnosis of fetal abnormality has been investigated in a series of 3785 amniotic fluid samples. Quantitative analysis of AChE performed retrospectively on a selected group of 541 amniotic fluid samples failed to discriminate between normal and open neural tube defect pregnancies. Qualitative analysis of AChE by polyacrylamide gel (PAG) electrophoresis in the same series of 541 fluids correctly identified 251 of the 255 pregnancies with open neural tube defect and 29 of the 31 pregnancies with false positive amAFP results. The failure of the test to diagnose 4 cases of open neural tube defect was probably attributable to the age and condition of the stored AF samples. Routine diagnostic testing of AChE isoenzymes in a further 3244 AF samples successfully identified all 170 cases of open neural tube defect and 20 cases with other fetal defects. Thirteen fluids gave false positive AChE results (0.4 per cent) compared to 59 of the series in which there were false positive amAFP results (1.8 per cent). Six of the 13 false positive AChE cases had AChE bands of low intensity which would not be regarded as diagnostic of fetal abnormality, and in five the AChE band may have been the result of significant blood contamination. False positive AChE results contributed to the decision to abort three apparently normal fetuses, but a normal AChE result undoubtedly helped to save a number of pregnancies with false positive amAFP results. Our experience suggests that repeating the amniocentesis may help in resolving the rare diagnostic difficulty of a positive AChE result with or without an elevated amAFP in the absence of ultrasound evidence of fetal abnormality, particularly where there is blood contamination of the amniotic fluid sample.  相似文献   

16.
Using a modified procedure by Solomons and Styner (1969), an evaluation of inorganic pyrophosphate (PPi) was performed on the amniotic fluid of two fetuses at risk for osteogenesis imperfecta (OI) at 14½ weeks gestation. The parents of both cases had a previous child with OI, Type II. The normal control group at 14–16 weeks gestation had PPi values ranging from 22.0–59.2 ug/100 ml, with a mean of 38.6±9.51 ug/100 ml. In each at-risk fetus, the amniotic fluid PPi value was within normal range. The first baby was born phenotypically normal at term. Intrauterine radiographic and fetal sonograms were done on the second fetus at approximately 19 weeks gestation. Both showed evidence of OI, Type II. The pregnancy was terminated at 21 weeks. Radiologic studies of the aborted fetus were consistent with OI, Type II. Our results indicate that the evaluation of PPi levels in amniotic fluid is not the method of choice for prenatal diagnosis of IO.  相似文献   

17.
In the context of a prospective study on the adverse effects of anti-epileptic drugs on fetal outcome, we evaluated our experience with prenatal diagnosis by ultrasonography and α- fetoprotein (AFP) determination in amniotic fluid. We compared these results with AFP values in maternal serum obtained prior to amniocentesis. From November 1985 to July 1990, amniocentesis at 16–18 weeks of gestation was performed in 267 pregnancies of 237 different women using anti-epileptic drugs. Among 92 pregnancies with maternal valproic acid use, five (including one concordantly affected monozygotic twin-pair) were terminated because of a spina bifida aperta, all prenatally diagnosed by AFP determination and acetylcholinesterase electrophoresis in amniotic fluid. The maternal serum AFP level was raised (⩾ 2.5 multiples of the median (MOM) for singleton pregnancies and ⩾ 4.5 MOM for twin pregnancies) in only two of these five affected pregnancies. We emphasize that maternal serum AFP levels may be unreliable for prenatal screening for fetal neural tube defects in women taking valproate and recommend that amniocentesis and fetal ultrasound examination should be offered directly.  相似文献   

18.
Alkaline phosphatase (ALP) activity was determined in 255 amniotic fluid samples collected by amniocentesis between 15 and 39 weeks of gestation. The samples were originally used for chromosomal analysis and/or alpha-fetoprotein measurements. The mean ALP activity in early amniotic fluid from pregnancies with fetal trisomy 18 and 21 syndromes was half of that found in the controls. Highly elevated ALP activity (over 10 times the median level) was found in 14 samples. Two of these pregnancies had normal outcome. Three samples were from pregnancies with intrauterine fetal death. Fetal disorders, including abdominal wall defect (four cases), Meckel's syndrome (two), hydrops fetalis syndrome (two) and genital anomaly (one), were observed in nine cases. Moderately elevated ALP activity (over three times the median) was found in 10 cases, including five pregnancies with a preterm labour shortly after the sample collection. The results indicate that elevated ALP activity in the third trimester amniotic fluid is often associated with fetal disorders.  相似文献   

19.
An analysis is made of alphafetoprotein (AFP) concentrations in 3630 amniotic fluids submitted for prospective prenatal diagnoses over a 7-year period. There were 89 cases of anencephaly, 74 of open spina bifida and 3467 with normal singleton outcomes. The AFP data were expressed in both standard deviations above the mean and multiples of the normal median for individual weeks of gestation. False positive and false negative rates were comparable in the two systems at selected cut-offs. It is concluded that either system may be used in setting action limits for the primary distinction of unaffected pregnancies from those in which an open neural tube defect is present.  相似文献   

20.
Acetylcholinesterase (AChE) gel electrophoresis was performed on samples of amniotic fluid and extraembryonic coelomic fluid obtained by high resolution transvaginal ultrasound-guided amniocentesis from 38 women between 8 and 12 weeks of pregnancy. AChE was positive in 33 per cent (12/36) of the amniotic fluid samples; the percentage of positive results decreased as gestation advanced. AChE was positive in 32 per cent (9/28) of the extraembryonic coelomic fluid samples. In 81 per cent (21/26) of matched samples, the AChE results were identical in the two fluids. Amniotic fluid and extraembryonic coelomic fluid AChE electrophoresis cannot be used to diagnose neural tube defects prior to 12 weeks of gestation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号