首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fungal spores are transported across great distances in the outdoor air and are also regularly found indoors. Building conditions and behavior-related problems in apartments may lead to massive growth of mold within a very short period of time.The aim of this study was to evaluate whether the visible growth of mold indoors influences the concentration of fungal spores in the air as well as the variety of their species. Samples were collected from 66 households in Austria. For each sampling, the corresponding outdoor air was measured as reference value. The size of the visible mold growth was categorized in order to correlate the extent of mold growth with the concentration of airborne spores as well as the fungal genera. In order to determine fungal spore concentrations in the air, the one-stage MAS-100® air sampler was used. Malt extract agar (MEA) and dichloran glycerol agar (DG18) plates were used as culture media. The total colony forming units (CFU) per m3 were determined. The fungi were identified from the isolated colonies.The results show that in apartments visibly affected by mold, the median values were significantly higher than those of apartments without visible mold growth. The extent of visible mold growth is significantly correlated with both concentration of fungal spores (p<0.001) as well as the predominance of Penicillium sp. and Aspergillus sp. (p<0.001) in indoor air. The total fungal concentration of Penicillium and Aspergillus in the air of apartments is recommended for assessing fungal exposure.  相似文献   

2.

The novel SARS-CoV-2 outbreak was declared as pandemic by the World Health Organization (WHO) on March 11, 2020. Understanding the airborne route of SARS-CoV-2 transmission is essential for infection prevention and control. In this study, a total of 107 indoor air samples (45 SARS-CoV-2, 62 bacteria, and fungi) were collected from different wards of the Hajar Hospital in Shahrekord, Iran. Simultaneously, bacterial and fungal samples were also collected from the ambient air of hospital yard. Overall, 6 positive air samples were detected in the infectious 1 and infectious 2 wards, intensive care unit (ICU), computed tomography (CT) scan, respiratory patients’ clinic, and personal protective equipment (PPE) room. Also, airborne bacteria and fungi were simultaneously detected in the various wards of the hospital with concentrations ranging from 14 to 106 CFU m?3 and 18 to 141 CFU m?3, respectively. The highest mean concentrations of bacteria and fungi were observed in respiratory patients’ clinics and ICU wards, respectively. Significant correlation (p < 0.05) was found between airborne bacterial concentration and the presence of SARS-CoV-2, while no significant correlation was found between fungi concentration and the virus presence. This study provided an additional evidence about the presence of SARS-CoV-2 in the indoor air of a hospital that admitted COVID-19 patients. Moreover, it was revealed that the monitoring of microbial quality of indoor air in such hospitals is very important, especially during the COVID-19 pandemic, for controlling the nosocomial infections.

  相似文献   

3.
This study was conducted to investigate the temporal and spatial distributions, compositions, and determinants of ambient aeroallergens in Taipei, Taiwan, a subtropical metropolis. We monitored ambient culturable fungi in Shin-Jhuang City, an urban area, and Shi-Men Township, a rural area, in Taipei metropolis from 2003 to 2004. We collected ambient fungi in the last week of every month during the study period, using duplicate Burkard portable samplers and Malt Extract Agar. The median concentration of total fungi was 1339 colony-forming units m−3 of air over the study period. The most prevalent fungi were non-sporulating fungi, Cladosporium, Penicillium, Curvularia and Aspergillus at both sites. Airborne fungal concentrations and diversity of fungal species were generally higher in urban than in rural areas. Most fungal taxa had significant seasonal variations, with higher levels in summer. Multivariate analyses showed that the levels of ambient fungi were associated positively with temperature, but negatively with ozone and several other air pollutants. Relative humidity also had a significant non-linear relationship with ambient fungal levels. We concluded that the concentrations and the compositions of ambient fungi are diverse in urban and rural areas in the subtropical region. High ambient fungal levels were related to an urban environment and environmental conditions of high temperature and low ozone levels.  相似文献   

4.
Residences located within 20 km of the damaged Fukushima Daiichi Nuclear Power Plant were evacuated shortly after the Great East Japan Earthquake. The levels of airborne and surface fungi were measured in six houses in the evacuation zone in August 2012 and February 2013. Airborne fungal levels in all of the houses in the summer were higher than the environmental standard levels for residential houses published in Architectural Institute of Japan (>1000 colony-forming units [CFU]/m3). In two houses whose residents rarely returned to visit, fungal levels were extremely high (>52,000 CFU/m3). Although fungal levels in the winter were much lower than those in the summer, they were still higher than environmental standard levels in several houses. Indoor fungal levels were significantly inversely related to the frequency with which residents returned, but they were not correlated with the air exchange rates, temperature, humidity, or radiation levels. Cladosporium spp. and Penicillium spp. were detected in every house. Aspergillus section Circumdati (Aspergillus ochraceus group) was also detected in several houses. These fungi produced ochratoxin A and ochratoxin B, which have nephrotoxic and carcinogenic potential. The present study suggests that further monitoring of fungal levels is necessary in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone, and that some houses may require fungal disinfection.

Implications: The results suggest that residents’ health could be at risk owing to the high levels of airborne fungi and toxic fungi Aspergillus section Circumdati. Therefore, monitoring and decontamination/disinfection of fungi are strongly recommended before residents are allowed to return permanently to their homes. In addition, returning to home with a certain frequency and adequate ventilation are necessary during similar situations, e.g., when residents cannot stay in their homes for a long period, because fungal levels in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone were inversely correlated with the frequency with which residents returned to visit their houses.  相似文献   


5.
A new type of air filtration medium made from a hygroscopic polymer fibre and constructed in three layers was investigated to measure the survival and growth of micro-organisms on this medium in comparison to a widely used fibreglass medium. Both materials were supplied by the manufacturer and tested “blind”. The materials were loaded in an Airotester unit. Micro-organisms were analysed at 2 weekly intervals for 8 weeks by washing filter samples and plating the solution on to agar media and by vital fluorescence microscopy. Filter samples were also weighed to calculate water content and the pH value of the filter material was measured in the wash out eluate. Vital fluorescence microscopy revealed fungi were able to grow on fibreglass medium, but not on the multi-layered polymer. The colony forming unit (CFU) counts did not increase at a steady rate. There was a significant increase on both materials (P<0.001) during the first 2 weeks which was then followed by a significant decrease in 4 weeks (P<0.001) but the CFU then significantly increased in 6 weeks (P<0.05) which were the highest CFU counts during the 2-month trial. There was a significant difference in CFU counts between the filter materials only in week 2 (P⩽0.001) and week 4 (P=0.04). Fewer micro-organisms were extracted from the multi-layered polymer than from the fibreglass medium. Fewer fungal species were identified on the multi-layered polymer (nine species) than on the fibreglass medium (13 species). The pH value on the multi-layered polymer was significantly higher than the fibreglass material but only when clean (P<0.010) and after 2 weeks (P<0.001). A significantly higher water content on the fibreglass medium (P<0.001) also indicated a habitat where a wider range of fungal species and bacteria are able to survive. While there was a reduced survival and growth of micro-organisms on the multi-layered polymer material in the initial month of service life, this advantage was cancelled by the supply of nutrients (particulate matter) that were accumulated on the filter materials after 6 weeks.  相似文献   

6.
自由表面流人工湿地微生物气溶胶研究   总被引:4,自引:0,他引:4  
微生物气溶胶的种类、浓度和粒径分布与人类健康关系密切。采用MD8空气浮游菌采样仪和FA-1型6级筛孔撞击式空气微生物采样器,对人工湿地细菌和真菌气溶胶的数量和粒径分布进行研究。结果表明,人工湿地进水前,细菌和真菌气溶胶平均值较低,分别为64.0、126.0CFU/m3;进水后,细菌气溶胶平均值在6月26日达到最高,为2292.5CFU/m3,真菌气溶胶平均值在8月27日达到最高,为6200.0CFU/m3;易进入肺部的细菌和真菌(粒径为0.65~4.70μm)粒子数分别占粒子总数的22.2%~62.3%、54.2%~87.6%;空气细菌中值直径为1.88~4.13μm,空气真菌中值直径在3.00μm左右波动。空气细菌中革兰氏阳性菌明显多于革兰氏阴性菌,空气真菌主要为酵母菌、镰刀菌属、枝孢属、毛霉属、交链孢属、肉座菌属、枝霉属、青霉属和曲霉属。  相似文献   

7.
In this study, the culturability of indoor and outdoor airborne fungi was determined through long-term sampling (24-h) using a Button Personal Inhalable Aerosol Sampler. The air samples were collected during three seasons in six Cincinnati area homes that were free from moisture damage or visible mold. Cultivation and total microscopic enumeration methods were employed for the sample analysis. The geometric means of indoor and outdoor culturable fungal concentrations were 88 and 102 colony-forming units (CFU) m(-3), respectively, with a geometric mean of the I/O ratio equal to 0.66. Overall, 26 genera of culturable fungi were recovered from the indoor and outdoor samples. For total fungal spores, the indoor and outdoor geometric means were 211 and 605 spores m(-3), respectively, with a geometric mean of I/O ratio equal to 0.32. The identification revealed 37 fungal genera from indoor and outdoor samples based on the total spore analysis. Indoor and outdoor concentrations of culturable and total fungal spores showed significant correlations (r = 0.655, p<0.0001 and r = 0.633, p<0.0001, respectively). The indoor and outdoor median viabilities of fungi were 55% and 25%, respectively, which indicates that indoor environment provides more favorable survival conditions for the aerosolized fungi. Among the seasons, the highest indoor and outdoor culturability of fungi was observed in the fall. Cladosporium had a highest median value of culturability (38% and 33% for indoor and outdoor, respectively) followed by Aspergillus/Penicillium (9% and 2%) among predominant genera of fungi. Increased culturability of fungi inside the homes may have important implications because of the potential increase in the release of allergens from viable spores and pathogenicity of viable fungi on immunocompromised individuals.  相似文献   

8.
The aim of this study was to characterise and quantify the fungal fragment propagules derived and released from several fungal species (Penicillium, Aspergillus niger and Cladosporium cladosporioides) using different generation methods and different air velocities over the colonies. Real time fungal spore fragmentation was investigated using an Ultraviolet Aerodynamic Particle Sizer (UVASP) and a Scanning Mobility Particle Sizer (SMPS). The study showed that there were significant differences (p < 0.01) in the fragmentation percentage between different air velocities for the three generation methods, namely the direct, the fan and the fungal spore source strength tester (FSSST) methods. The percentage of fragmentation also proved to be dependent on fungal species. The study found that there was no fragmentation for any of the fungal species at an air velocity ≤0.4 m s?1 for any method of generation. Fluorescent signals, as well as mathematical determination also showed that the fungal fragments were derived from spores. Correlation analysis showed that the number of released fragments measured by the UVAPS under controlled conditions can be predicted on the basis of the number of spores, for Penicillium and A. niger, but not for C. cladosporioides. The fluorescence percentage of fragment samples was found to be significantly different to that of non-fragment samples (p < 0.0001) and the fragment sample fluorescence was always less than that of the non-fragment samples. Size distribution and concentration of fungal fragment particles were investigated qualitatively and quantitatively, by both UVAPS and SMPS, and it was found that the UVAPS was more sensitive than the SMPS for measuring small sample concentrations, whilethe results obtained from the UVAPS and SMAS were not identical for the same samples.  相似文献   

9.
Characteristics of microbial aerosols released from chicken and swine feces   总被引:1,自引:0,他引:1  
Bioaerosols generated during livestock and poultry production are significant occupational hazards. This study investigates the characteristics of bioaerosols released from animal feces. Fresh feces from pigs and chickens were obtained and tested in a controlled-environment facility. Airborne viable (culturable) bacteria and fungi were sampled hourly for 48 hr. The predominant species were identified via polymerase chain reaction analysis. The number of bacterial colonies released from chicken feces increased gradually, peaked at approximately 20 hr, and remained relatively constant to test end; however, the bacterial colonies released from swine feces did not increase significantly. The chicken feces released significantly (P < 0.05) more bacterial aerosols than swine feces over 40 hr, by approximately 1 order of magnitude. However, the difference in total fungal aerosols released from the two feces types was relatively small (30-40%) and insignificant (P > 0.05). Aerosols sized between approximately 0.65 and 1.1 microm were predominant for bacteria, whereas aerosols sized between approximately 2.1 and 3.3 microm prevailed for fungi. Genera Stenotrophomonas were the predominant bacterial aerosols, whereas Cladosporium and Acremonium accounted for the greatest amounts of fungi from chicken and swine feces, respectively. More than 1000 culturable bacterial colonies can be released from 1 g of chicken feces per hour, and approximately 80% of these bioaerosols are respirable. Most bacterial aerosols released from swine and chicken feces were opportunistic human pathogens; thus, the significance of their presence warrants further investigations.  相似文献   

10.
In this study, the effects of tetracycline exposure on wheat growth and the microbial community structure in the rhizosphere were investigated under hydroponic culture conditions. Exposure to various concentrations of tetracycline resulted in significant suppression of the growth of wheat roots and shoots, with minimum doses of 0.8 mg L?1 and 4 mg L?1 resulting in inhibition rates of 32% and 15.4%, respectively. Complete inhibition of the growth of these two parts of wheat plants was observed in response to treatment with tetracycline at 20 mg L?1 and 100 mg L?1, respectively. However, the germination of wheat seeds was not sensitive to exposure to tetracycline. The effects of tetracycline exposure on the microbial community in the wheat rhizosphere were evaluated through traditional cultivation and molecular biological analyses. The cultivation results indicated that bacteria were the dominant population, being present in concentrations of 1× 108–2.45× 109CFUs mL?1, although 39% to 87% inhibition occurred in response to tetracycline. The concentration of fungi increased in all tetracycline treated samples to 2.5 to 15.8 times that of the control. The highest concentration of fungi (4.27× 108 CFU mL?1) was observed in response to 60 mg L?1 tetracycline after 15 days of cultivation. In this stage, a large amount of fungal colonies was observed on the surface of the culture solution, the wheat roots became rotted and the plants became atrophic or even died. Molecular biological analysis indicated that the bacterial community structure was significantly different in samples that were exposed to high levels of tetracycline (over 20 mg L?1) than in samples that were exposed to lower concentrations. As the concentration of tetracycline increased, the diversity of the bacteria decreased. Additionally, several dominant sensitive species such as Sphingobacterium multivorum were suppressed by tetracycline, while some resistant species such as Acinetobacter sp. appeared or were conserved. The bacteria population tended to stabilize when the drug concentration exceeded 40 mg L?1.  相似文献   

11.
Fungi exposure has been linked to asthma and allergies among children. To determine the association between fungal exposure and wheeze and rhinitis symptoms, we examined concentrations of culturable indoor and outdoor fungi of various aerodynamic sizes in low and high allergic prevalence child care centers (CCCs) in Singapore. Environmental parameters were also performed for air temperature, relative humidity and ventilation rates, while information on CCC characteristics was collected via an inspection. Most commonly recovered fungi were Penicillium, Aspergillus, Geotrichum, Cladosporium and sterile mycelia with Geotrichum and sterile mycelia amounting to an average of 71.5% of the total airborne culturable fungi studied. Indoor and outdoor total culturable fungi concentrations and those in the size range of 1.1–3.3 μm were significantly higher in high allergic prevalence CCCs. When fungal types/genera were compared, indoor and outdoor Geotrichum and sterile mycelia of aerodynamic sizes 1.1–3.3 μm were found to be significantly elevated in high allergic prevalence CCCs. Indeed, average geometric mean diameters (Dg, ave) of indoor and outdoor culturable fungi were consistently smaller in CCCs with high prevalence of allergies than those with low prevalence. We found significant associations of higher fungal concentrations, especially those with smaller aerodynamic sizes in CCCs situated near parks. There were no differences in fungal levels between CCCs with respect to their dampness profile mainly due to high CCC ventilation rates. Since particle size is a factor that determines where a fungi particle deposits in the respiratory tract, this study provides useful information in the etiology of wheeze and rhinitis symptoms among the CCC attending children.  相似文献   

12.
Jo WK  Kang JH 《Chemosphere》2006,65(10):1755-1761
The present study evaluated exposure to bioaerosols at three different types of facilities (pet shops, pet clinics, and flower gardens) by measuring the bacterial, fungal and/or PM(10) concentrations in indoor and outdoor air. Regardless of the season, the total bacteria and total fungi were detected for all samples, whereas the fungal genera were not. The bioaerosol concentrations measured in the flower gardens were significantly higher than those of the pet shops and pet clinics. The mean microbial concentrations at the three types of facilities were close to or exceeded the Korean indoor bioaerosol guidelines (800 CFU m(-3)), thus suggesting the need for remedial action regarding indoor microorganisms, in order to reduce the exposure at the surveyed facilities. Another suggestion was that contrary to the airborne microbes, flower gardens are not an important microenvironment for PM(10) (particulate matter 10 microm in aerodynamic diameter) exposure. Two temporal characteristics (seasonal variation and the summer survey period) were important regarding exposure to airborne microbes, depending upon the type of facility surveyed, microbial or sample types, whereas the sampling time of the day was not. The microbial concentration ratio of indoor air to outdoor air depended upon the facility and season.  相似文献   

13.
Between 18 March and 27 October 2002, 220 air samples were collected on 209 of 224 calendar days, on top of a coastal atmospheric research tower in Erdemli, Turkey. The volume of air filtered for each sample was 340 liters. Two hundred fifty-seven bacterial and 2598 fungal colony forming units (CFU) were enumerated from the samples using a low-nutrient agar. Ground-based dust measurements demonstrated that the region is routinely impacted by dust generated regionally and from North Africa and that the highest combined percent recovery of total CFU and African dust deposition occurred in the month of April (93.4% of CFU recovery and 91.1% of dust deposition occurred during African dust days versus no African dust present, for that month). A statistically significant correlation was observed (peak regional African dust months of March, April and May; rs=0.576, P=0.000) between an increase in the prevalence of microorganisms recovered from atmospheric samples on dust days (regional and African as determined by ground-based dust measurements), versus that observed on non-dust days. Given the prevalence of atmospherically suspended desert dust and microorganisms observed in this study, and that culture-based studies typically only recover a small fraction (<1.0%) of the actual microbial population in any given environment, dust-borne microorganisms and other associated constituents (organic detritus, toxins, etc.) may play a significant role in the regional human and ecosystem health.  相似文献   

14.
Abstract

Existing quantitative standards/guidelines for fungi in indoor air issued by governmental agencies are based primarily on baseline data (rather than health effects data), and are either absolute (numerical) or relative (indoor/outdoor comparisons) or a combination of the two. The Russian Federation is the only governmental agency that has binding quantitative regulations for bioaerosols. Recommended guidelines have been proposed or sponsored by North American and European governmental agencies and private professional organizations. A considerable number of frequently cited guidelines have been proposed by individuals based either on baseline data or on personal experience. Quantitative standards/guidelines range from less than 100 CFU/ m3 to greater than 1000 CFU/m3 (total fungi) as the upper limit for non-contaminated indoor environments.

Major issues with existing quantitative standards and guidelines are the lack of connection to human dose/response data, reliance on short term grab samples analyzed only by culture, and the absence of standardized protocols for data collection, analysis, and interpretation. Urgent research needs include the study of human responses to specific fungal agents, development and widespread use of standard protocols using currently available sampling methodologies, and the development of long term, time-discriminating personal samplers that are inexpensive, easy to use, and amenable to straightforward, relevant analysis.  相似文献   

15.
Bacteria and fungi in pristine and oily desert soil samples were counted on inorganic medium aliquots containing 0.5% hexadecane, hexadecanol, hexadecanal or hexadecanoic acid, as sole sources of carbon and energy. It was found that the carbon and energy source most commonly utilized by soil bacteria was the alkane n-hexadecane, and by soil fungi hexadecanoic acid. Representative microorganisms were isolated and identified. The most predominant bacteria in all soil samples belonged to the genera Micrococcus and Pseudomonas; less dominant bacteria belonged to the group of nocardioforms. The most frequent fungal genera were Aspergillus and Penicillium, while Microsporium and Ulocladium were minor fungi. Irrespective of the substrate on which the microbial strains had initially been isolated, the majority of the isolated microorganisms could grow, albeit to a varying degree, on an inorganic medium containing any of the remaining three substrates as sole carbon and energy sources. Bacterial strains preferred the alkane as a carbon and energy source over any of its oxidation products, while fungal strains preferred to grow mainly on the fatty acids. Quantitative analysis by gas liquid chromatography revealed that the predominant bacterial and fungal isolates had a potential for the attenuation of the alkane and its immediate oxidation products in the medium. In view of the continuous release of hydrocarbon oxidation products by oil-utilizing microorganisms in oily environments, it is interesting that the indigenous microflora contribute to the uptake and utilization of all such intermediate compounds, thus, having a potential for efficient self-cleaning and bioremediation of oily soils.  相似文献   

16.
Jo WK  Seo YJ 《Chemosphere》2005,61(11):1570-1579
One major deficiency in linking environmental exposure to health effects is the current lack of data on environmental exposure. Therefore, to address this issue, the present study measured the bacterial and fungal concentrations in the indoor and outdoor air from two types of recreation facility (42 bars and 41 Internet cafes), 44 classrooms at 11 elementary schools, and 20 homes under uncontrolled environmental conditions during both summer and winter. No major environmental problems were reported at the four microenvironments being investigated during the entire study period. Bacteria and fungi were found in all the air samples, and the environmental occurrence of individual fungi was in the order of Cladosprium, Penicillium, Aspergillus, and Alternaria. The six parameters surveyed in the present study were all found to influence the indoor and outdoor bioaerosol levels: microenvironment type, sampling time in elementary school classrooms, agar type for measuring the fungal species, seasonal variation, facility location, and summer survey periods. The indoor and outdoor air concentrations of bacteria and fungi found in this study were comparable to those in other reports, with GM values for the total bacteria and total fungi between 10 and 103 colony-forming units per cubic meter of air (CFU m−3). The fungal concentrations found at most of the indoor environments fell within the specified guidelines of the American Conference of Government Industrial Hygienists (ACGIH), between 100 and 1000 CFU m−3 for the total fungi. However, the indoor bioaerosol concentrations at most of the surveyed environments exceeded the Korean indoor bioaerosol guideline (800 CFU m−3). Consequently, the current findings suggest the need for reducing strategy for indoor microorganisms at the surveyed microenvironments.  相似文献   

17.
The release of Aspergillus versicolor, Cladosporium cladosporioides, and Penicillium melinii spores from agar and ceiling tile surfaces was tested under different controlled environmental conditions using a newly designed and constructed aerosolization chamber. This study revealed that all the investigated parameters, such as fungal species, air velocity above the surface, texture of the surface, and vibration of contaminated material, affected the fungal spore release. It was found that typical indoor air currents can release up to 200 spores cm−2 from surfaces with fungal spores during 30-min experiments. The release of fungal spores from smooth agar surfaces was found to be inadequate for accurately predicting the emission from rough ceiling tile surfaces because the air turbulence increases the spore release from a rough surface. A vibration at a frequency of 1 Hz at a power level of 14 W resulted in a significant increase in the spore release rate. The release appears to depend on the morphology of the fungal colonies grown on ceiling tile surfaces including the thickness of conidiophores, the length of spore chains, and the shape of spores. The spores were found to be released continuously during each 30-min experiment. However, the release rate was usually highest during the first few minutes of exposure to air currents and mechanical vibration. About 71–88% of the spores released during a 30-min interval became airborne during the first 10 min.  相似文献   

18.
Contamination by microscopic fungi and mycotoxins in different bee pollen samples, which were stored under three different ways of storing as freezing, drying and UV radiation, was investigated. During spring 2009, 45 samples of bee-collected pollen were gathered from beekeepers who placed their bee colonies on monocultures of sunflower, rape and poppy fields within their flying distance. Bee pollen was collected from bees’ legs by special devices placed at the entrance to hives. Samples were examined for the concentration and identification of microscopic fungi able to grow on Malt and Czapek-Dox agar and mycotoxins content [deoxynivalenol (DON), T-2 toxin (T-2), zearalenone (ZON) and total aflatoxins (AFL), fumonisins (FUM), ochratoxins (OTA)] by direct competitive enzyme-linked immunosorbent assays (ELISA). The total number of microscopic fungi in this study ranged from 2.98 ± 0.02 in frozen sunflower bee pollen to 4.06 ± 0.10 log cfu.g?1 in sunflower bee pollen after UV radiation. In this study, 449 isolates belonging to 21 fungal species representing 9 genera were found in 45 samples of bee pollen. The total isolates were detected in frozen poppy pollen 29, rape pollen 40, sunflower pollen 80, in dried poppy pollen 12, rape pollen 36, sunflower 78, in poppy pollen after UV radiation treatment 54, rape 59 and sunflower 58. The most frequent isolates of microscopic fungi found in bee pollen samples of all prevalent species were Mucor mucedo (49 isolates), Alternaria alternata (40 isolates), Mucor hiemalis (40 isolates), Aspergillus fumigatus (33 isolates) and Cladosporium cladosporioides (31 isolates). The most frequently found isolates were detected in sunflower bee pollen frozen (80 isolates) and the lowest number of isolates was observed in poppy bee pollen dried (12 isolates). The most prevalent mycotoxin of poppy bee pollen was ZON (361.55 ± 0.26 μg.kg?1), in rape bee pollen T-2 toxin (265.40 ± 0.18 μg.kg?1) and in sunflower bee pollen T-2 toxin (364.72 ± 0.13 μg.kg?1) in all cases in frozen samples.  相似文献   

19.
It is well known that characterization of airborne bioaerosols in indoor environments is a challenge because of inherent irregularity in concentrations, which are influenced by many environmental factors. The primary aim of this study was to quantify the day-to-day variability of airborne fungal levels in a single residential environment over multiple seasons. Indoor air quality practitioners must recognize the inherent variability in airborne bio-aerosol measurements during data analysis of mold investigations. Changes in airborne fungi due to varying season and day is important to recognize when considering health impacts of these contaminants and when establishing effective controls. Using an Andersen N6 impactor, indoor and outdoor bioaerosol samples were collected on malt extract agar plates for 18 weekdays and 19 weekdays in winter and summer, respectively. Interday and intraday variability for the bioaerosols were determined for each sampler. Average fungal concentrations were 26 times higher during the summer months. Day-to-day fungal samples showed a relatively high inconsistency suggesting airborne fungal levels are very episodic and are influenced by several environmental factors. Summer bio-aerosol variability ranged from 7 to 36% and winter variability from 24 to 212%; these should be incorporated into results of indoor mold investigations. The second objective was to observe the relationship between biological and nonbiological particulate matter (PM). No correlation was observed between biological and nonbiological PM. Six side-by-side particulate samplers collected coarse PM (PM10) and fine PM (PM2.5) levels in both seasons. PM2.5 particulate concentrations were found to be statistically higher during summer months. Interday variability observed during this study suggests that indoor air quality practitioners must adjust their exposure assessment strategies to reflect the temporal variability in bioaerosol concentrations.  相似文献   

20.
Aerobiological studies in commuting trains in northern Taiwan were carried out from August, 2007 until July, 2008. Two six-stage (>7 μm, 4.7~7 μm, 3.3~4.7 μm, 2.1~3.3 μm, 1.1~2.1 μm, 0.65~1.1 μm) cascade impactors of 400 orifices were used to collect viable bacteria and fungi, respectively. The levels of carbon monoxide (CO), carbon dioxide (CO2), formaldehyde (HCHO), temperature, and relative humidity in the commuting trains were also recorded during the sampling period. Results show that bacterial concentrations ranged from 25 to 1530 CFU m?3, and averaged 417 CFU m?3. The fungal concentrations ranged from 45 to 1906 CFU m?3, and averaged 413 CFU m?3. Additionally, the highest fractions occurred in the fifth stage (1.1~2.1 μm) for both bacteria and fungi. The respirable fractions, Rb and Rf, for bacteria and fungi were 62.8% and 81.4%, respectively, which are higher than those in other studies. Furthermore, the bacterial concentration reached its highest level in autumn, and its lowest level in winter. However, the fungal concentration was highest in spring and lowest in winter. Though the total bacterial or fungal concentration did not exceed the recommendation standard in Taiwan, the relatively high respirable fraction in commuting trains probably implies a higher adverse health risk for sensitive commuters. This study further conducted multiple regression analysis to determine the relationship of various stage fractions of airborne bacteria and fungi with indoor air pollutants (CO and HCHO) and environmental parameters (CO2, temperature, and relative humidity). The correlation coefficients of multiple regression analysis for total bacteria and fungi concentrations with indoor air pollutants and environmental parameters were 0.707 (p < 0.00376) and 0.612 (p < 0.00471), respectively. There are currently no formally regulated laws for indoor air quality (IAQ) in Taiwan, and this preliminary study can provide references to the Taiwan government on IAQ management.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号