首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
在研究旋风除尘器内气固两相的运动状况及分离机理方面,计算机模拟替代部分实验的方法能够优化设计旋风除尘器结构参数,提高其对微细颗粒的捕集效率,减少运行压力损失。本研究采用RSM模型和随机轨道模型对旋风除尘器内流场及浓度场进行模拟及实验。研究表明,旋风除尘器压力损失模拟结果与实验结果吻合较好,对于大于5μm的颗粒其捕集效率模拟结果与实验结果基本吻合;旋风除尘器外壁的颗粒浓度呈螺旋带状分布;如将排气管管径减少至原直径0.8倍,可使其对2μm颗粒捕集效率提高6.6%,但压力损失提高36.5%;颗粒的凝并作用有利于提高旋风除尘器微细颗粒的捕集效率。  相似文献   

2.
Liquid entrainment separation was studied experimentally for packed bed, knitted mesh, zigzag baffle, tube bank, and cyclone type apparatus. Primary collection efficiency data compare well with theoretical predictions but re-entrainment of the collected liquid did not agree with theoretical models. Separation efficiency, drop size, and pressure drop data are presented.  相似文献   

3.
利用五孔探针系统对直筒式旋风静电除尘器模型的三维流场进行了测定与分析.结果表明:随着入口风速、供电电压增加,旋风静电除尘器内气流的切向和径向速度分别增加,各截面轴向速度沿半径的分布基本相似;与旋风除尘器相比,旋风静电除尘器内气流的切向速度和径向速度的变化更为平缓,入口风速为8.5 m/s时,在0.3~0.5倍简体直径时,切向速度达最大.  相似文献   

4.
An electrostatic precipitator, furnished on a 500-Mw tan-gentially-fired steam generator burning coal, was to collect 99.6% of the fly ash being generated in the furnace of this unit. Preliminary measurements indicated that the installation was not meeting its collection guarantee. Precipitator outlet flue dust distribution indicated that poor gas flow distribution might be one of the causes of the low performance. When observation ports were installed in the outlet flue to permit a direct visual evaluation of the problem, it was found that high velocity jets were present in the collecting electrodes, and that hopper sweepage was present. A model study along with velocity distribution measurements of the installation were authorized. Flow analysis indicated that the field and model correlated well. Extensive changes were made in the model, which eliminated or minimized the high velocity jets and hopper sweepage. After these changes were made in the field installation, it was able to achieve the required dust collection efficiency.  相似文献   

5.
使用五孔球探针对一种用于分离锅炉净化烟气中含尘液滴的直筒型导叶直流式三相旋流器排气管上部的气相流场进行了实验测定。得到了这一区域的速度和静压分布。发现了排气管上部筒体中心存在强烈的内旋流;外层气体不断汇入内旋流,内旋流呈轴向加速运动;绝大部分气体不经过排气管外环形空间下行直接由排气管排出。主体段切向速度为Rankine组合涡。  相似文献   

6.
为了进一步提高电除尘器的收尘效率,尤其是对高比电阻粉尘的收尘效率,依据非稳态静电收集理论,对影响电除尘器粉尘收集性能各项因素的作用程度及机理进行了进一步研究。实验研究了粉尘收尘效率与不同比电阻粉尘的最优极间距、最优工作电压、粉尘层厚度和比电阻之间的相互关系。研究结果表明,随着极间距的增加,对应比收尘极面积,对于不同比电阻粉尘的收尘效率的增加幅度是不同的,其中高比电阻粉尘的收尘效率增加的趋势更加显著;粉尘比电阻越高,所对应的最优极间距越大,宽间距电除尘器对捕集高比电阻粉尘具有一定优越性;在最优极间距条件下,粉尘比电阻越高,其所对应的最优工作电压越小;相对于正常比电阻粉尘,随极板沉积粉尘层厚度的增加,高比电阻粉尘的最佳收尘效率所对应的最优工作电压升高幅度较大,而且最优工作电压所对应的收尘效率下降显著。随粉尘比电阻的增大,电除尘器收尘效率逐渐降低,特别是当粉尘比电阻大于1011Ω.cm后,粉尘收尘效率显著下降。研究结果与非稳态静电收尘理论提出的观点相吻合,有助于透彻理解电场结构和运行参数与粉尘收集性能的关系,特别是对于今后研发提高高比电阻粉尘收集性能的针对性技术措施具有指导作用。  相似文献   

7.
A large number of pressurized coal gasification processes being developed propose to use venturi scrubbers for particulate removal at high pressures. Theoretical predictions based on venturi scrubber performance models indicate that particle collection efficiency will decrease severely in these high gas pressure applications.

An exploratory theoretical and experimental program was performed to study the effect of gas pressure on venturi scrubber performance. Experiments were done on a 0.47 m3/s (1000 acfm) pilot scale venturi scrubber. Particle collection performance was determined as a function of scrubber pressure drop for venturi scrubbers operating In the range of 1-10 atm total pressure. Experimental results confirmed that the particle collection efficiency of venturi scrubbers decreases for a given scrubber pressure drop as total gas pressure Is increased. To achieve the same particle collection efficiency, the pressure drop across a venturi scrubber operated at 10 atm Is about 10 times that of the same scrubber operated at 1 atm pressure.  相似文献   

8.
Electrostatic precipitation is considered as an effective technology for fine particle removal. A lab-scale wet electrostatic precipitator (ESP) with wire-to-plate configuration was developed to study particle migration and collection. The performance of the wet ESP was evaluated in terms of the corona discharge characteristics, total removal efficiency and fractional removal efficiency. The corona discharge characteristics and particle removal abilities of the wet ESP were investigated and compared with dry ESP. Particle removal efficiency was influenced by discharge electrode type, SO2 concentration, specific collection area (SCA) and particle/droplet interaction. Results showed that the particle removal efficiency of wet ESP was elevated to 97.86% from 93.75% of dry ESP. Three types of discharge electrodes were investigated. Higher particle removal efficiency and larger migration velocity could be obtained with fishbone electrode. Particle removal efficiency decreased by 2.87% when SO2 concentration increased from 0 ppm to 43 ppm as a result of the suppression of corona discharge and particle charging. The removal efficiency increased with higher SCA, but it changed by only 0.71% with the SCA increasing from 25.0 m2/(m3/s) to 32.5 m2/(m3/s). Meanwhile, the increasing of particle and droplet concentration was favorable to the particle aggregation and improved particle removal efficiency.

Implications: This work tends to study the particle migration and collection under spraying condition. The performance of a wet electrostatic precipitator (ESP) is evaluated in terms of the corona discharge characteristics, total particle removal efficiency, and fractional particle removal efficiency. The effects of water droplets on particle removal, especially on removal of particles with different sizes, is investigated. The optimization work was done to determine appropriate water consumption, discharge electrode type, and specific collection area, which can provide a basis for wet ESP design and application.  相似文献   


9.
Pulse-jet filter cleaning is ineffective to the extent that collected dust redeposits rather than falls to the hopper. Dust tracer techniques were used to measure the amount of redeposition in a pilot scale pulse-jet filter. A mathematical model based on experimental results was developed to describe dust transfer from bag to bag, redeposition on the pulsed bag itself, and migration to the dust hopper. Dust redeposition upon the pulsed bag increased markedly with increasing filtration velocity, whereas migration and redeposition on bags adjacent to the pulsed bag decreased. For high velocity pulse-jet filters to operate at lowest possible pressure drop, filter cake redeposition must be minimized.  相似文献   

10.
A novel two-stage wet electrostatic precipitator (ESP) has been developed using a carbon brush pre-charger and collection plates with a thin water film. The electrical and particle collection performance was evaluated for submicrometer particles smaller than 0.01- 0.5 micrometer in diameter by varying the voltages applied to the pre-charger and collection plates as well as the polarity of the voltage. The collection efficiency was compared with that calculated by the theoretical models. The long-term performances of the ESP with and without water films were also compared in tests using Japanese Industrial Standards dust. The experimental results show that the carbon brush pre-charger of the two-stage wet ESP had approximately 10% particle capture, while producing ozone concentrations of less than 30 ppb. The produced amounts of ozone are significantly lower than the current limits set by international agencies. The ESP also achieved a high collection rate performance, averaging 90% for ultrafine particles, as based on the particle number concentration at an average velocity of 1 m/sec corresponding to a residence time of 0.17 sec. Higher particle collection efficiency for the ESP can be achieved by increasing the voltages applied to the pre-charger and the collection plates. The decreased collection efficiency that occurred during dust loading without water films was completely avoided by forming a thin water film on the collection plates at a water flow rate of 6.5 L/min/m(2).  相似文献   

11.
The flow rate through an industrial gas-cleaning cyclone at a fixed pressure drop is greater when the incoming gas is dusty than when it is clean. This observation by Briggs for a single cyclone tube was extended to multiple tubes, and ike results compared to observations by Soo and Trezek that the fraction factor for turbulent flow in a pipe is less for dusty gas than for clean. Empirical considerations indicated tJtat both of these observations should be connected with a rather large reduction in gas viscosity due to the dust. This predicted viscosity decrease was later observed. A physical theory accounting for viscosity reduction by a dust cloud is proposed. This effect also offers a means for increasing the heat, transfer coefficient in gas heat exchangers.  相似文献   

12.
In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 microm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38-99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1-1 microm. In this size range, ESP and baghouse collection efficiencies are 85.79-98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

13.
利用电动修复技术对铅污染土壤的修复进行了实验室研究,研究了修复时间和络合剂EDTA对电动修复效果的影响,分析了土壤重金属的迁移和变化特征。结果表明,在电场力作用下随着修复时间的增长污染物的去除率相应提高,去除率由修复时间5 d时的13%增加到15 d时的20%。以EDTA作为阴极控制液,EDTA可与硝酸铅反应形成溶解态的络合物,提高铅离子的移动性,从而提高修复效果。随着EDTA浓度由0.1 mol/L到0.2 mol/L,Pb的去除率由44.4%提高到61.5%,说明添加络合剂可以提高修复效果。另外,电动修复效果与铅的形态分布有密切关系,交换态和碳酸盐结合态有利于重金属铅的去除。  相似文献   

14.
A self-flushing wet electrostatic precipitator was developed to investigate the removal performance for fine particles. Flexible material (polypropylene, 840A) and carbon steel in the form of a spiked band were adopted as the collection plate and discharge electrode, respectively. The particle concentration, morphology, and trace-element content were measured by electric low-pressure impactor, scanning electron microscope, and energy-dispersive x-ray spectroscopy, respectively, before and after the electrostatic precipitator. With increasing gas velocity, the collection efficiency of fine particles (up to 0.8 μm in diameter) increased, while it decreased for particles with diameters larger than 0.8 μm. Increasing the dust inlet concentration increased the collection efficiency up to a point, from which it then declined gradually with further increases in the inlet concentration. The particulate matter after the wet electrostatic precipitator showed different degrees of agglomeration. The collection efficiency of trace elements within PM10 was less than that of the PM10 itself. Notably, the water consumption in the current setup was significantly lower than for other treatment processes of comparable collection efficiencies.

Implications: Wet electrostatic precipitators, as fine filtration equipment, were generally applicable to coal-fired plants to reduce PM2.5 emissions in China. However, high energy consumption and unstable operation, such as water usage and spray washing directly in the electric field, seriously restricted the further development. The utilization of self-flushing wet electrostatic precipitator can solve these problems to some extent.  相似文献   


15.
A laboratory-scale study was conducted using a completely mixed reactor with a constant influent-total-organic carbon (TOC) of 3750 mg/L to evaluate the effect of increasing influent-sulfate levels on anaerobic-treatment performance. The sulfate levels were increased stepwise from 333 to 666, 1000, 1333 and 1666 mg S/L. The results showed that an elevation of influent sulfate actually increased the TOC removal efficiency as long as the produced sulfide level did not induce toxicity. At 1333 mg S/L influent sulfate, the produced dissolved sulfide was 613 mg S/L (free sulfide = 228 mg S/L), which started to impose toxicity to the methane-producing bacteria (MPB). It was also found that the percent electron flow to the sulfate-reducing pathway increased with the increasing influent sulfate, but the direction toward the methanogenesis was correspondingly reduced. Nevertheless, under the experimental conditions tested, the majority of the influent organics was still degraded through the methanogenic pathway. Through this study, an oxidation-reduction-potential (ORP)-based oxygenation process was developed for online oxidation of sulfide in recirculating biogas. With controlled oxygen injection to raise the reactor's ORP by 25 mV, the residual sulfide in the reactor was almost totally eliminated. In case of over oxygenation, any excess oxygen was quickly consumed by the facultative organisms in the reactor, thereby imposing no toxicity to the MPB.  相似文献   

16.
Abstract

In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 µm. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38–99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1–1 µm. In this size range, ESP and baghouse collection efficiencies are 85.79–98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM10 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.  相似文献   

17.
A size selective particle sampler has been developed for continuous sampling of the urban aerosol over periods ranging from hours to weeks, providing relatively large sample weights. The system, which is now operating in New York City, uses a parallel array of two-stage samplers. The cyclones used as the first stage collectors have 50% particle retention at 3.5,2.5,1.5 and 0.5 µm aerodynamic diameter, respectively. Undersize particles which pass through the cyclones are captured on glass fiber filters. Equal intake velocities are assured by using flow equalizers on the inlets to the cyclones. Accurate control of the flow through the cyclones is obtained by the use of an integrated circuit pressure transducer in conjunction with a specially designed feedback control circuit. The collection efficiencies of the cyclone were calibrated using monodisperse ferric oxide test aerosols tagged with Tc-99m. Mass balances of the par-ticulates collected on the cyclones and filters are obtained for the five sampling stages. Preliminary results show the distributions of the total suspended particulates in New York City to be bimodal. The distributions of lead, copper, and manganese with particle size are also discussed.  相似文献   

18.
A modified model of venturi scrubber performance has been developed that addresses two effects of liquid surface tension: its effect on droplet size and its effect on particle penetration into the droplet. The predictions of the model indicate that, in general, collection efficiency increases with a decrease in liquid surface tension, but the range over which this increase is significant depends on the particle size and on the scrubber operating parameters. The predictions further indicate that the increases in collection efficiency are almost totally due to the effect of liquid surface tension on the mean droplet size, and that the collection efficiency is not significantly affected by the ability of the particle to penetrate the droplet.  相似文献   

19.
Tropical cyclones are prominent weather systems characterized by high atmospheric pressure gradients and wind speeds. Intense tropical cyclones occur in India during the pre-monsoon (spring), early monsoon (early summer), or post-monsoon (fall) periods. Originating in both the Bay of Bengal (BoB) and the Arabian Sea (AS), these tropical cyclones often attain velocities of more than 100 km h?1 and are notorious for causing intense rain and storm surge as they cross the Indian coast. In this study, we examine the changes in the aerosol properties associated with an intense tropical cyclone “SIDR”, that occurred during 11–16 November 2007 over BoB. This cyclone, accompanied with very strong surface winds reaching 223 km h?1, caused extensive damage over Bangladesh. Ground-based measurements of Aerosol Optical Depth (AOD) in the neighboring urban environment of Hyderabad, India, showed significant variations due to changes in wind velocity and direction associated with the cyclone passage. The Terra-MODIS and AVHRR satellite images showed prevalence of dust particles mixed with emissions from anthropogenic sources and biomass-burning AS, while the aerosol loading over BoB was significantly lower. The positive values of Aerosol index (AI) obtained from the Ozone Monitoring Instrument (OMI) suggested the presence of an elevated aerosol layer over the West coast of India, AS and Thar Desert during and after the cyclone episode. Meteorological parameters from the MM5 mesoscale model were used to study the variations in winds associated with the cyclonic activity. Particulate matter loading over the region during the cyclone period increased by ~45% with an accompanying decrease in columnar aerosol optical depth. The variations in Angstrom parameters suggested coarse-mode particle loading due to dust aerosols as observed in satellite data.  相似文献   

20.
Wu HL  Lu SY  Yan JH  Li XD  Chen T 《Chemosphere》2011,84(3):361-367
The fly ash used in this study was collected from a bag filter in a medical waste rotary kiln incineration system, using lime and activated carbon injection followed by their collection as mixed fly ash. Experiments were conducted on fly ash in a quartz tube, heated in a laboratory-scale horizontal tube furnace, in order to study the effect of temperature and nitrogen flow rate on the removal of PCDD/Fs. Results indicated that in this study PCDD/Fs in the fly ash mostly were removed and desorbed very little into the flue gas under thermal treatment especially when the heating temperature was higher than 350 °C, and dechlorination and destruction reactions took important part in the removal of PCDD/Fs. However, in terms of flow rate, when flow rate was higher than 4 cm s−1, destruction efficiency of PCDD/Fs decreased dramatically and the main contributors were P5CDF, H6CDF and H7CDF desorbed to flue gas, the PCDD/Fs in the fly ash decreased with enhanced flow rate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号