首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The thermal decomposition of SF6 is known to be oxygen-independent. Nevertheless, because of its high stability, the use of SF6 as a "conservative" surrogate in incinerator performance evaluation has been advocated and researched. This paper shows that refractory decreases markedly the stability of SF6. The resulting increase in SF6 decomposition was from 0 percent to 95 percent at 900°C, and the temperatures at which 90-99 percent decomposition occurred were lowered by 300-150°C. Refractory also decreased the stability of CCl4 and C2Cl4, but to a lesser extent. The difference between the decompositions of C2Cl4 and SF6 was reduced from several orders of magnitude to a factor of 2-4. Such a drastic and adverse change in relative stability could render SF6 unsuitable as a "conservative" surrogate. The requirements for a "conservative" surrogate and the need for caution in its use are discussed, and further research areas are indicated.  相似文献   

2.
This paper discusses the Chemical Manufacturers Association's 1984 survey of the chemical industry's hazardous waste management practices. The survey data include a breakdown of how the industry's hazardous wastes are managed, detailing generation, treatment and disposal, and cover 725 plants in 81 companies. The 1984 survey is the third CM A hazardous waste survey, and the paper discusses resultant waste treatment trends from 1981- 1984, the period covered by previous surveys. A total of 278.5 million tons of hazardous waste was treated and disposed by survey respondents. Of this, 276.8 million tons was hazardous wastewater and 1.7 million tons was solid hazardous waste. The survey solid hazardous waste total was projected to the entire industry (Standard Industrial Code 2800) and is estimated at 6.9 million tons. The survey showed continued decreasing trends in hazardous waste generation in the chemical industry. It demonstrated changes in hazardous waste management practices, with decreased use of landfills and increased incineration of the solid wastes that are generated.  相似文献   

3.
Measurements conducted on full-scale hazardous waste incinerators have occasionally shown a relationship between carbon monoxide (CO) emissions and emissions of toxic organic compounds. In this study, four mixtures of chlorinated C1 and C2 hydrocarbons were diluted in commercial-grade heptane and burned in a water-cooled turbulent flame reactor (TFR) under two different excess air levels. No correlation between CO and organic emissions could be discerned. Reasons for this lack of observable correlations are discussed in terms of combustion and chemical reaction kinetic theory.  相似文献   

4.
Abstract

The University of Houston is located just south of downtown Houston, TX. Many different chemical substances are used in scientific research and teaching activities throughout the campus. These activities generate a significant amount of waste materials that must be discarded as regulated hazardous waste per U.S. Environmental Protection Agency (EPA) rules. The Texas Commission on Environmental Quality (TCEQ) is the state regulatory agency that has enforcement authority for EPA hazardous waste rules in Texas. Currently, the University is classified as a large quantity generator and generates >1000 kg per month of hazardous waste. In addition, the University has experienced a major surge in research activities during the past several years, and overall the quantity of the hazardous waste generated has increased. The TCEQ requires large quantity generators to prepare a 5-yr Pollution Prevention (P2) Plan, which describes efforts to eliminate or minimize the amount of hazardous waste generated. This paper addresses the design and development of a low-cost P2 plan with minimal implementation obstacles and strong payoff potentials for the University. The projects identified can be implemented with existing University staff resources. This benefits the University by enhancing its environmental compliance efforts, and the disposal cost savings can be used for other purposes. Other educational institutions may benefit by undertaking a similar process.  相似文献   

5.
危险废物焚烧飞灰中重金属的稳定化处理   总被引:9,自引:1,他引:8  
以上海市某危险废物焚烧厂飞灰为研究对象,采用Na2S、FeSO4、Na3PO4、和Na3C3N3S34种不同类型化学稳定药剂对飞灰进行了稳定化处理,并应用XRD、IR、SEM和连续化学提取法等仪器和手段对Na3C3N3S3处理焚烧飞灰的产物进行分析研究。研究结果表明,Na3C3N3S3对飞灰中的重金属Cr、Pb、Zn的稳定效果最好,Na3PO4对Cr无明显稳定效果。稳定后产物表面变得致密化,Na3C3N3S3与重金属离子生成的沉淀物干燥后无明显晶型存在。经稳定处理后飞灰中的重金属形态由弱酸提取态转化为可氧化态,减少了飞灰中重金属的浸出毒性。  相似文献   

6.
The University of Houston is located just south of downtown Houston, TX. Many different chemical substances are used in scientific research and teaching activities throughout the campus. These activities generate a significant amount of waste materials that must be discarded as regulated hazardous waste per U.S. Environmental Protection Agency (EPA) rules. The Texas Commission on Environmental Quality (TCEQ) is the state regulatory agency that has enforcement authority for EPA hazardous waste rules in Texas. Currently, the University is classified as a large quantity generator and generates >1000 kg per month of hazardous waste. In addition, the University has experienced a major surge in research activities during the past several years, and overall the quantity of the hazardous waste generated has increased. The TCEQ requires large quantity generators to prepare a 5-yr Pollution Prevention (P2) Plan, which describes efforts to eliminate or minimize the amount of hazardous waste generated. This paper addresses the design and development of a low-cost P2 plan with minimal implementation obstacles and strong payoff potentials for the University. The projects identified can be implemented with existing University staff resources. This benefits the University by enhancing its environmental compliance efforts, and the disposal cost savings can be used for other purposes. Other educational institutions may benefit by undertaking a similar process.  相似文献   

7.
掌握填埋废物的工程力学特性是确保危险废物填埋堆体稳定性的重要前提条件,因此,针对6种典型危险废物的工程力学特性开展了调查研究.研究结果表明,污泥类危险废物的含水率和有机质含量远高于非污泥类危险废物,而前者的比重则显著低于后者.污泥类危险废物的渗透系数相对较小,比污染土壤和飞灰炉渣混合物的渗透系数小1个数量级,比滤池填料的渗透系数小2个数量级.不同危险废物的无侧限抗压强度排序为:飞灰炉渣混合物(314.3 kPa)和滤池填料(278.9 kPa)>污染土壤(124.9 kPa)>杭州氧气厂污泥(68.6 kPa)、锌铬污泥(71.4 kPa)、油泥(58.4 kPa).不同危险废物的粘聚力排序为:飞灰炉渣混合物(40.8 kPa)、滤池填料(31.1 kPa)>污染土壤(20.9 kPa)>杭州氧气厂污泥(1.94kPa)、锌铬污泥(3.10 kPa)、油泥(1.81 kPa).此外,不同危险废物的内摩擦角差异相对较小,其变化范围在18.8°~35.0°之间.综合分析可知,飞灰炉渣混合物和滤池填料的工程力学特性较好,而污泥类危险废物的工程力学特性则较差.  相似文献   

8.
Correlations between products of incomplete combustion (PIC), e.g., chloroaromatic compounds, can be used to characterise the emissions from combustion processes, like municipal or hazardous waste incineration. A possible application of such relationships may be the on-line real-time monitoring of a characteristic surrogate, e.g., with Resonance-Enhanced Multiphoton Ionization-Time-of-Flight Mass Spectrometry (REMPI-TOFMS). In this paper, we report the relationships of homologues and individual congeners of chlorinated benzenes (PCBz), dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and phenols (PCPh) to the International Toxicity Equivalent (I-TEQ) of the PCDD/F (I-TEQ value) in the flue gas and stack gas of a 22 MW hazardous waste incinerator (HWI). As the REMPI detection sensitivity is decreasing with the increase of the degree of chlorination, this study focuses on the lower chlorinated species of the compounds mentioned above. Lower chlorinated species, e.g., chlorobenzene (MCBz), 1,4-dichlorobenzene, 2,4,6-trichlorodibenzofuran or 2,4-dichlorophenol, were identified as I-TEQ surrogates in the flue gas. In contrast to the higher chlorinated phenols, the lower chlorinated phenols (degree of chlorination <4) were not reliable as surrogates in the stack gas. The identified surrogates are evaluated in terms of their detectability by REMPI-TOFMS laser mass spectrometry. The outcome is that MCBz is the best suited surrogate for (indirect) on-line measuring of the I-TEQ value in the flue gas by REMPI-TOFMS. The correlation coefficient r of the MCBz concentration to the I-TEQ in the flue gas was 0.85.  相似文献   

9.
This paper explores the potential of a hazardous waste of difficult management, electric arc furnace dust (EAFD), as photocatalytic material. Starting from a real waste coming from a Spanish steel factory, chemical, mineralogical, and optical characterizations have been carried out. Direct trials on EAFD and mortar containing this waste have been performed to evaluate its potential as photocatalyst itself and within a cementitious material. The analysis of photocatalytic properties has been done by two different methods: degradation of NO x and degradation of rhodamine (RhB). As a result, it can be said that EAFD exhibited photocatalytic activity for both configurations with UV and visible light, having the mortar enhanced photocatalytic activity for NO x with respect to the EAFD itself. Additionally, in direct trials on the EAFD, it has been able to degrade RhB even in the dark, which has been attributed to transfer of electrons between the adsorbed RhB and the conduction band of some oxides in the dust.  相似文献   

10.
This article is a series of representative case studies of Department of Defense hazardous waste minimization. Each Military Department and the Defense Logistics Agency describe actual accomplishments. Areas covered range from production line modification to product specification change. These efforts are part of a Department of Defense plan composed of individual programs executed independently by each military service and defense agency.

Part VII of the hazardous waste minimization series appears in two separate installments: this installment, Part VII (A), deals with Department of Defense waste minimization efforts in vehicle repair operations, explosives manufacturing, and abrasive blasting processes; Part VII (B) will cover shipboard mercury wastes, industrial chemical control, solvent reclamation, and hazardous property sales efforts.  相似文献   

11.
This article is a series of representative case studies of Department of Defense hazardous waste minimization. Each Military Department and the Defense Logistics Agency describe actual accomplishments. Areas covered range from production line modification to product specification change. These efforts are part of a Department of Defense plan composed of individual programs executed independently by each military service and defense agency.

Part VII of the hazardous waste minimization series appears in two separate installments: the first installment, Part VII (A), dealt with Department of Defense waste minimization efforts in vehicle repair operations, explosives manufacturing, and abrasive blasting processes; Part VII (B) covers shipboard mercury wastes, industrial chemical control, solvent reclamation, and hazardous property sales efforts.  相似文献   

12.
小型垃圾热处理设备可实现就地处置,节约运输成本,目前在中国山区、丘陵地带的村镇得到广泛应用.为了解村镇小型生活垃圾热处理炉底渣的理化特性及其影响因素,对中国云南、贵州、安徽村镇实际运行的小型生活垃圾热处理设备产生的底渣进行取样,分析其热灼减率、物理组成、化学组成、晶相组成、重金属含量和浸出特性,探讨处理工艺、地域及季节...  相似文献   

13.

Chromium-containing solid wastes have been generated by chemical and leather/tanning industries, and the management and proper disposal of the same wastes have been challenging tasks. A significant fraction of these wastes contains chromium compounds with chromium present in the hexavalent (Cr+6) form, which is hazardous to human beings, animals, and ecosystems. Since these wastes are discarded largely without proper treatments, soil and groundwater get contaminated and they can cause several health issues to human beings. Conventional methods developed to convert hazardous Cr6+ to Cr3+/Cr metal either generate secondary toxic wastes and unwanted by-products and/or are time-consuming processes. In this work, a plasma-assisted aluminothermic process is developed to convert the toxic waste into non-toxic products. The waste was mixed with aluminium powder and subjected to transferred arc plasma treatment in a controlled air atmosphere. Chemical analysis and Cr leachability studies of the waste material prior to plasma treatment have shown that it is highly toxic. Analysis of the products obtained from the plasma treatment showed that Cr and Fe present in the waste could be recovered as a metallic mixture as well as oxide slag, which were found to be non-toxic. Easy separation of the metallic fraction and the slag from the treated product is one of the merits of this process. Besides converting chromium-containing toxic waste to non-toxic materials, the process is rapid and recovers the metals from the waste completely.

  相似文献   

14.
Several designated hazardous wastes (metal plating waste, oil sludge, heavy metal processing sludge) were studied relative to potential detoxification using dry calcium based FGD sludges. The FGD waste was generated from a pilot scale system which utilized slurried lime, a spray drier, and a bag filter. Following detailed physical and chemical identification of the raw FGD and hazardous wastes, various mixtures were prepared and cured. In all cases, even with the organic sludge, a rigid structural material evolved due to the pozzolanic reactions occurring from the wetted dry FGD waste. Structural characteristics, physical character, and chemical leaching effects were evaluated. The solids were leached via both EPA-RCRA and ASTM proposed leaching procedures. In all cases, the hazardous constituents were retained and not leached. Finally, the feasibility of using dry FGD wastes as fixating materials is discussed.  相似文献   

15.
The quantity and composition of RCRA hazardous wastes incinerated during 1986 were examined using the National Hazardous Waste Survey. This Survey, collected for U.S. EPA by the Research Triangle Institute, is the most extensive examination of hazardous waste generation and management available. The survey data show that although a wide variety of hazardous wastes were treated by incineration, more than 75 percent of incinerated waste streams were from chemical manufacturing. The survey data also show that more than 90 percent of the incinerated wastes were treated by incinerators located at the facility generating the waste. Despite the predominance of a single industrial sector in generating incinerated hazardous wastes, the compositional profile of the wastes is far from uniform. To illustrate this variability, the metals and chlorine content of the wastes are reported along with the sources of the metal and chlorine loadings.  相似文献   

16.
The ChemChar Process, a non-incinerative thermolytic technology designed to destroy hazardous and non-hazardous wastes, was studied using the surrogate compound hexachlorobenzene (HCB). The process was varied from the conventional mode of operation, and thermal degradation products of HCB were collected in sampling trains. A mechanism of thermal destruction was proposed from experimental results and comparison to known mechanisms employing similar coal conversion technology.  相似文献   

17.
Pollution resulting from hazardous glass (HG) is widespread across the globe, both in terms of quantity and associated health risks. In waste cathode ray tube (CRT) and fluorescent lamp glass, mercury and lead are present as the major pollutants. The current review discusses the issues related to quantity and associated risk from the pollutant present in HG and proposes the chemical, biological, thermal, hybrid, and nanotechniques for its management. The hybrid is one of the upcoming research models involving the compatible combination of two or more techniques for better and efficient remediation. Thermal mercury desorption starts at 100 °C but for efficient removal, the temperature should be >460 °C. Involvement of solar energy for this purpose makes the research more viable and ecofriendly. Nanoparticles such as Fe, Se, Cu, Ni, Zn, Ag, and WS2 alone or with its formulation can immobilize heavy metals present in HG by involving a redox mechanism. Straight-line equation from year-wise sale can provide future sale data in comparison with lifespan which gives future pollutant approximation. Waste compact fluorescent lamps units projected for the year 2015 is 9,300,000,000 units and can emit nearly 9,300 kg of mercury. On the other hand, CRT monitors have been continuously replaced by more improved versions like liquid crystal display and plasma display panel resulting in the production of more waste. Worldwide CRT production was 83,300,000 units in 2002 and can approximately release 83,000 metric tons of lead.  相似文献   

18.
The destruction/removal efficiency (DRE), and the ability to accurately measure it, is a function of the concentration of the chemical compound in the input waste, the incinerator design and operation, sampling methods, and the analytical procedures. All of these are interrelated. This paper discusses the basic DRE equation [DRE = WIn Wout)/Win × 100] and how it relates to some of the other destruction parameters. Some example data from the literature are presented. While PCBs have been used as the example, the equations and graphs are equally valid for some other hazardous compounds (POHCs), with the substitution of the 99.99% DRE requirement in lieu of the 99.9999% DRE for PCBs. The use of the relationships discussed in this paper should allow incinerator operators to more efficiently plan demonstration test burns which will adequately demonstrate the DRE.  相似文献   

19.
Dry scrubbing of the flue gas from chemical waste incineration is becoming an increasingly viable alternative to wet scrubbing. This paper discusses the relative advantages and disadvantages of wet and dry scrubbing systems and compares the relative capital and operating costs. The design parameters of the dry scrubbing process are discussed, including reagent atomization, gas dispersion, gas temperatures, and particulate removal. The history of dry scrubbing process applications is discussed, including the successful European hazardous waste systems. Finally, a comparison is made among three very different hazardous waste incinerators in the U.S. that will utilize dry scrubbing systems.  相似文献   

20.
某厂化学镀镍线产生的主要污染物为大气污染、水污染和固体废物污染。其中大气污染物主要为硫酸雾。水污染物为总镍、总铜、化学需氧量、悬浮物、总磷、氨氮等。固废废弃物均为危险废物,包括废包装材料、酸性废液、含镍废液。该文分析了化学镀镍线产生的废气、废水和固体废物的主要来源,并提出了防止污染的对策。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号